Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control Product concentration

Product Concentration Control. Product concentration is one of the most important evaporator system control parameters. It can be determined from the solution density, as assumed in the discussion above, or the boiling point rise (BPR). [Pg.1162]

Before the equivalence point, the concentration of Cr04 is controlled by the solubility product of PbCr04. After the equivalence point, the concentration of Cr04 is determined by the amount of excess titrant added. Considering the reactions controlling the concentration of Cr04 , sketch the expected titration curve of pH versus volume of titrant. [Pg.366]

In order to control the concentration of lower dibasic acid by-products in the system, a portion of the mother liquor stream is diverted to a purge treatment process. Following removal of nitric acid by distillation (Fig. 3, K), copper and vanadium catalyst are recovered by ion-exchange treatment (Fig. [Pg.244]

With respect to the action of the enzyme itself, a loss of weight on account of cellulose hydrolysis, as well as loss in strength properties, occurs. Therefore, control of concentrations, temperature, and other processing conditions is important to achieve a product having the proper balance of properties. [Pg.447]

Product concentration can be controlled by any property of the solution that can be measured with the requisite accuracy and reh-ability. The preferred method is to impose control on rate of product... [Pg.1148]

The common indices of the physical environment are temperature, pressure, shaft power input, impeller speed, foam level, gas flow rate, liquid feed rates, broth viscosity, turbidity, pH, oxidation-reduction potential, dissolved oxygen, and exit gas concentrations. A wide variety of chemical assays can be performed product concentration, nutrient concentration, and product precursor concentration are important. Indices of respiration were mentioned with regard to oxygen transfer and are particularly useful in tracking fermentation behavior. Computer control schemes for fermentation can focus on high productiv-... [Pg.2149]

The study of relative rates by the competitive method can be useful. The principle was discussed in Section 3.1 in the context of parallel reactions, for which the ratio of the product concentrations is equal to the ratio of rate constants (provided the concentrations are under kinetic control). [Pg.180]

Significant improvement of tantalum powder properties was achieved by the application of molten alkali halides as solvents for potassium heptafluorotantalate, K2TaF7. Variation of the initial concentration of K2TaF7 in the melt, stirring and rate of sodium loading enable a well-controllable production of tantalum powder with a wide variety of specific charges. Heller and Martin [590] proposed the use of a reactor equipped with a stirrer in 1960. Fig. 142 shows a typical scheme of the reactor [24, 576]. All metal parts of the reactor are made of nickel or nickel alloy. [Pg.331]

In biochemical engineering processes, measurement of dissolved oxygen (DO) is essential. The production of SCP may reach a steady-state condition by keeping the DO level constant, while the viable protein is continuously harvested. The concentration of protein is proportional to oxygen uptake rate. Control of DO would lead us to achieve steady SCP production. Variation of DO may affect retention time and other process variables such as substrate and product concentrations, retention time, dilution rate and aeration rate. Microbial activities are monitored by the oxygen uptake rate from the supplied ah or oxygen. [Pg.14]

The reaction heat is removed by the vacuum evaporation of dilution water. The resulting water vapors allow complete degassing and stripping of any trace of undesired low boiling by products (i.e., 1,4-dioxane for ethoxy sulfates). The product temperature is accurately controlled with the vacuum level kept in the reactor and by the temperature control in the reactor jacket. The automatic control of the different process parameters, i.e., flow rate of reagents, vacuum degree, temperature of thermostatting water, also allows for accurate control of the product concentration. [Pg.695]

An acyclic enone, 2-ethyl-l-phenylprop-2-en-l-one, was reduced with the yeast Pichia stipitis CCT 2617 [19cj. The reduction proceeded chemo- and enantioselec-tively to afford (S)-2-ethyl-l-phenylprop-2-en-l-ol (65% yield, >99% ee). XAD-7 was used to decrease and control the concentration of both the substrate and the product (Figure 8.25). [Pg.212]

An example of cascade control could be based on the simulation example DEACT and this is shown in Fig. 2.35. The problem involves a loop reactor with a deactivating catalyst, and a control strategy is needed to keep the product concentration Cp constant. This could be done by manipulating the feed rate into the system to control the product concentration at a desired level, Cjet- In this cascade control, the first controller establishes the setpoint for flow rate. The second controller uses a measurement of flow rate to establish the valve position. This control procedure would then counteract the influence of decreasing catalyst activity. [Pg.105]

Figure 2.35. Cascade control to maintain product concentration by manipulating the reactant concentration in the feed. Figure 2.35. Cascade control to maintain product concentration by manipulating the reactant concentration in the feed.
In order to determine reaction rate constants and reaction orders, it is necessary to determine reactant or product concentrations at known times and to control the environmental conditions (temperature, homogeneity, pH, etc.) during the course of the reaction. The experimental techniques that have been used in kinetics studies to accomplish these measurements are many and varied, and an extensive treatment of these techniques is far beyond the intended scope of this textbook. It is nonetheless instructive to consider some experimental techniques that are in general use. More detailed treatments of the subject are found in the following books. [Pg.37]

Light intensity at the usual levels seldom has an effect on the primary photochemical step if all other variables are kept constant, although it may affect overall results considerably since it may control the concentrations of reactive intermediates. However, it will affect the outcome of a competition between primary one-photon and two-photon processes. The latter are still somewhat of a rarity but may be more important than is commonly realized, namely in rigid media where triplets have long lifetimes and quite a few of them are likely to absorb a second photon. The additional available energy may permit motion to new minima in Ti and thus give new products. [Pg.27]

The infrared technique has been described in numerous publications and recent reviews were published by Davies and Giangiacomo (2000), Ismail et al. (1997) and Wetzel (1998). Very few applications have been described for analysis of additives in food products. One interesting application is for controlling vitamin concentrations in vitamin premixes used for fortification of food products by attenuated total reflectance (ATR) accessory with Fourier transform infrared (FTIR) (Wojciechowski et al., 1998). Four vitamins were analysed - Bi (thiamin), B2 (riboflavin), B6 (vitamin B6 compounds) and Niacin (nicotinic acid) - in about 10 minutes. The partial least squares technique was used for calibration of the equipment. The precision of measurements was in the range 4-8%, similar to those obtained for the four vitamins by the reference HPLC method. [Pg.130]

Diffusion Rate Controlled Process If the rate of chemical reaction is much faster than the diffusion of water and EG through the solid amorphous phase, then the reaction can be considered to be at equilibrium throughout the pellet [21], The reaction rate is dependent upon the pellet size, the diffusivity of both water and EG, the starting molecular weight, and the equilibrium constants Ki and K5. In addition, the pellet can be expected to have a radial viscosity profile due to a by-product concentration profile through the pellet with the molecular weight increasing as the by-product concentrations decreases in the direction of the pellet surface [22-24],... [Pg.152]


See other pages where Control Product concentration is mentioned: [Pg.222]    [Pg.529]    [Pg.270]    [Pg.1148]    [Pg.2145]    [Pg.2145]    [Pg.287]    [Pg.65]    [Pg.601]    [Pg.230]    [Pg.89]    [Pg.698]    [Pg.568]    [Pg.187]    [Pg.34]    [Pg.116]    [Pg.11]    [Pg.144]    [Pg.235]    [Pg.237]    [Pg.11]    [Pg.161]    [Pg.184]    [Pg.226]    [Pg.74]    [Pg.391]    [Pg.36]    [Pg.53]    [Pg.223]    [Pg.510]    [Pg.989]    [Pg.223]   
See also in sourсe #XX -- [ Pg.304 ]




SEARCH



Caustic evaporation product concentration control

Concentrates products

Dust control, concentrate production

Product control

Product controlling

Product solution concentration control testing

Production controls

© 2024 chempedia.info