Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control, mass spectrometry

Amines have odd numbered molecular weights which helps identify them by mass spectrometry Fragmentation tends to be controlled by the formation of a nitrogen stabilized cation... [Pg.958]

The various stages of this process depend critically on the type of gas, its pressure, and the configuration of the electrodes. (Their distance apart and their shapes control the size and shape of the applied electric field.) By controlling the various parameters, the discharge can be made to operate as a corona, a plasma, or an arc at atmospheric pressure. All three discharges can be used as ion sources in mass spectrometry. [Pg.43]

The nebulization concept has been known for many years and is commonly used in hair and paint spays and similar devices. Greater control is needed to introduce a sample to an ICP instrument. For example, if the highest sensitivities of detection are to be maintained, most of the sample solution should enter the flame and not be lost beforehand. The range of droplet sizes should be as small as possible, preferably on the order of a few micrometers in diameter. Large droplets contain a lot of solvent that, if evaporated inside the plasma itself, leads to instability in the flame, with concomitant variations in instrument sensitivity. Sometimes the flame can even be snuffed out by the amount of solvent present because of interference with the basic mechanism of flame propagation. For these reasons, nebulizers for use in ICP mass spectrometry usually combine a means of desolvating the initial spray of droplets so that they shrink to a smaller, more uniform size or sometimes even into small particles of solid matter (particulates). [Pg.106]

Analytical methods iaclude thin-layer chromatography (69), gas chromatography (70), and specific methods for determining amine oxides ia detergeats (71) and foods (72). Nuclear magnetic resonance (73—75) and mass spectrometry (76) have also been used. A frequentiy used procedure for iadustrial amine oxides (77) iavolves titratioa with hydrochloric acid before and after conversion of the amine to the quaternary ammonium salt by reaction with methyl iodide. A simple, rapid quaHty control procedure has been developed for the deterrniaation of amine oxide and unreacted tertiary amine (78). [Pg.192]

Tandem mass spectrometry or ms/ms was first introduced in the 1970s and gained rapid acceptance in the analytical community. The technique has been used for stmcture elucidation of unknowns (26) and has the abiUty to provide sensitive and selective analysis of complex mixtures with minimal sample clean-up (27). Developments in the mid-1980s advancing the popularity of ms/ms included the availabiUty of powerhil data systems capable of controlling the ms/ms experiment and the viabiUty of soft ionisation techniques which essentially yield only molecular ion species. [Pg.405]

Mass Spectrometer. The mass spectrometer is the principal analytical tool of direct process control for the estimation of tritium. Gas samples are taken from several process points and analy2ed rapidly and continually to ensure proper operation of the system. Mass spectrometry is particularly useful in the detection of diatomic hydrogen species such as HD, HT, and DT. Mass spectrometric detection of helium-3 formed by radioactive decay of tritium is still another way to detect low levels of tritium (65). Accelerator mass spectroscopy (ams) has also been used for the detection of tritium and carbon-14 at extremely low levels. The principal appHcation of ams as of this writing has been in archeology and the geosciences, but this technique is expected to faciUtate the use of tritium in biomedical research, various clinical appHcations, and in environmental investigations (66). [Pg.15]

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

Laser ionization mass spectrometry or laser microprobing (LIMS) is a microanalyt-ical technique used to rapidly characterize the elemental and, sometimes, molecular composition of materials. It is based on the ability of short high-power laser pulses (-10 ns) to produce ions from solids. The ions formed in these brief pulses are analyzed using a time-of-flight mass spectrometer. The quasi-simultaneous collection of all ion masses allows the survey analysis of unknown materials. The main applications of LIMS are in failure analysis, where chemical differences between a contaminated sample and a control need to be rapidly assessed. The ability to focus the laser beam to a diameter of approximately 1 mm permits the application of this technique to the characterization of small features, for example, in integrated circuits. The LIMS detection limits for many elements are close to 10 at/cm, which makes this technique considerably more sensitive than other survey microan-alytical techniques, such as Auger Electron Spectroscopy (AES) or Electron Probe Microanalysis (EPMA). Additionally, LIMS can be used to analyze insulating sam-... [Pg.586]

Two relatively new techniques, matrix assisted laser desorption ionization-lime of flight mass spectrometry (MALDI-TOF) and electrospray ionization (FS1), offer new possibilities for analysis of polymers with molecular weights in the tens of thousands. PS molecular weights as high as 1.5 million have been determined by MALDI-TOF. Recent reviews on the application of these techniques to synthetic polymers include those by Ilantoif54 and Nielen.555 The methods have been much used to provide evidence for initiation and termination mechanisms in various forms of living and controlled radical polymerization.550 Some examples of the application of MALDI-TOF and ESI in end group determination are provided in Table 3.12. The table is not intended to be a comprehensive survey. [Pg.143]

The control of materials purity and of environmental conditions requires to implement physico-chemical analysis tools like ESC A, RBS, AUGER, SEM, XTM, SIMS or others. The principle of SIMS (Secondary Ion Mass Spectroscopy) is shown in Eig. 31 an ion gun projects common ions (like 0+, Ar+, Cs+, Ga+,. ..) onto the sample to analyze. In the same time a flood gun projects an electron beam on the sample to neutralize the clusters. The sample surface ejects electrons, which are detected with a scintillator, and secondary ions which are detected by mass spectrometry with a magnetic quadrupole. [Pg.340]

The mass spectrometry employed electrospray ionization and each metabolite gave an [M + H]+ ion which was then used as a precursor ion for a product-ion MS-MS scan. For subsequent MS" experiments, the base peak of the previous MS-MS experiment was chosen under computer control and this allowed all analytes to be studied in a single chromatographic separation. [Pg.266]

Figure 5.67 Reconstructed ion chromatograms for Idoxifene and internal standard (ds-Idoxifene using LC-ToF-MS for (a) double-blank human plasma extract, (b) extract of blank human plasma containing internal standard (IS), and (c) control-blank human plasma spiked with Idoxifene at 5 gml , the LOQ of the method. Reprinted from 7. Chromatogr., B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science. Figure 5.67 Reconstructed ion chromatograms for Idoxifene and internal standard (ds-Idoxifene using LC-ToF-MS for (a) double-blank human plasma extract, (b) extract of blank human plasma containing internal standard (IS), and (c) control-blank human plasma spiked with Idoxifene at 5 gml , the LOQ of the method. Reprinted from 7. Chromatogr., B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science.
C and 5 N values were determined by mass spectrometry (MM 903, VG Isogas), equipped with a CN elemental analyzer (Roboprep CN, Europa Scientific). As control for sample purity, C N ratios from the elemental analyser were compared with C N ratios as calculated from the amino acid profile of the same sample. [Pg.177]

Huelsemann F., Flenker, U., Koehler, K, Schaenzer, W. (2009). Effect of a controlled dietary change on carbon and nitrogen stable isotope ratios of human hair. Rapid Communications in Mass Spectrometry Vol 23, pp. 2448-2454. [Pg.160]

The application of a selective pyrolysis process to the recovery of chemicals from waste PU foam is described. The reaction conditions are controlled so that target products can be collected directly from the waste stream in high yields. Molecular beam mass spectrometry is used in small-scale experiments to analyse the reaction products in real time, enabling the effects of process parameters such as temperature, catalysts and co-reagents to be quickly screened. Fixed bed and fluidised bed reactors are used to provide products for conventional chemical analysis to determine material balances and to test the concept under larger scale conditions. Results are presented for the recycling of PU foams from vehicle seats and refrigerators. 12 refs. [Pg.79]

To obtain the maximum concentration of MX2 species, the conditions for these reactions were first optimized by the pyrolytic mass spectrometry method (Kagramanov et al., 1983a). The contents of the mixture during the electron diffraction experiments were controlled by a quadrupole mass spectrometer. [Pg.31]

Advanced techniques like molecularly imprinted polymers (MIPs), infrared/near infrared spectroscopy (FT-IR/NIR), high resolution mass spectrometry, nuclear magnetic resonance (NMR), Raman spectroscopy, and biosensors will increasingly be applied for controlling food quality and safety. [Pg.314]

We have undertaken a series of experiments Involving thin film models of such powdered transition metal catalysts (13,14). In this paper we present a brief review of the results we have obtained to date Involving platinum and rhodium deposited on thin films of tltanla, the latter prepared by oxidation of a tltanliua single crystal. These systems are prepared and characterized under well-controlled conditions. We have used thermal desorption spectroscopy (TDS), Auger electron spectroscopy (AES) and static secondary Ion mass spectrometry (SSIMS). Our results Illustrate the power of SSIMS In understanding the processes that take place during thermal treatment of these thin films. Thermal desorption spectroscopy Is used to characterize the adsorption and desorption of small molecules, In particular, carbon monoxide. AES confirms the SSIMS results and was used to verify the surface cleanliness of the films as they were prepared. [Pg.81]

To determine its activity, the catalyst was placed in a quartz microreactor. Reactants were supplied through mass flow controllers and the product composition was determined by mass spectrometry. A typical reaction mixture contained 3.600 ppm NO, 1.06% CH4, and 6.0%... [Pg.662]

LC/MS/MS. LC/MS/MS is used for separation and quantitation of the metabolites. Using multiple reaction monitoring (MRM) in the negative ion electrospray ionization (ESI) mode, LC/MS/MS gives superior specificity and sensitivity to conventional liquid chromatography/mass spectrometry (LC/MS) techniques. The improved specificity eliminates interferences typically found in LC/MS or liquid chro-matography/ultraviolet (LC/UV) analyses. Data acquisition is accomplished with a data system that provides complete instmment control of the mass spectrometer. [Pg.383]


See other pages where Control, mass spectrometry is mentioned: [Pg.23]    [Pg.205]    [Pg.23]    [Pg.205]    [Pg.240]    [Pg.295]    [Pg.142]    [Pg.226]    [Pg.529]    [Pg.604]    [Pg.105]    [Pg.321]    [Pg.334]    [Pg.335]    [Pg.46]    [Pg.163]    [Pg.297]    [Pg.286]    [Pg.285]    [Pg.162]    [Pg.178]    [Pg.14]    [Pg.134]    [Pg.53]    [Pg.112]    [Pg.413]    [Pg.707]    [Pg.92]    [Pg.86]    [Pg.346]   
See also in sourсe #XX -- [ Pg.610 ]




SEARCH



Liquid chromatography mass spectrometry doping control

Mass control

Mass controlling

Mass spectrometry quality control samples

Mass spectrometry synthesis quality control

© 2024 chempedia.info