Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conformity evaluation

The methyl substituted spiro system JO (Fig. 3) was also studied (24, 25). With this system, two isomers JJ and J2 are possible and molecular models show that they can each exist in four different conformations. Evaluation of the anomeric and the steric effects of each conformation leads to the prediction that isomer JJ exists in the conformation 11A only (0 kcal/mol relative to the other conformations) whereas isomer 12 is a mixture of a major (12A, 2.4 kcal/mol) and a minor (12B, 2.9 kcal/mol) conformer. However, since isomers JJ and J2 are interconvertible (JJ can be converted into the mirror image of J2 by opening and reclosure of the acetal function) and... [Pg.207]

Saraf A, Hacker MC, Sitharaman B et al (2008) Synthesis and conformational evaluation of a novel gene delivery vector for human mesenchymal stem cells. Biomacromolecules 9 (3) 818-827... [Pg.185]

Conduct type approval of measurement instruments used by the field laboratories for the conformity evaluation to the specific regulations under their responsibility... [Pg.243]

It must be stressed that any discussion of furanose systems in terms of a single, exclusively populated conformation may be unrealistic. However, even approximate conformational evaluations of these systems can yield chemically significant conclusions.102,105... [Pg.202]

EN 459 Building lime . Part 1 Definitions, specifications and conformity criteria , DD ENV 459-1,1995 (being revised) Part 2 Test methods , BS EN 459-2,1995 (being revised) Part 3 Conformity evaluation , prEN 459-3, in preparation. [Pg.297]

European directives are an important instrument of the New Approach in the field of technical harmonisation and standardisation. They are intended to remove the technical barriers by harmonising product regulations and conformity evaluations. No specifications but only essential requirements restricted to the protection of health and safety of users and the protection of environment, are laid down in the New Approach directives. Up to 2000 some 20 directives have come into force. The directives cover products where safety aspects are relevant such as lifts, pressure equipment, explosion-proof materials, toys and personal safety equipment. [Pg.238]

The user inspectorate must fulfil the same technical criteria as the notified body. In addition, it must be organisationally identifiable and demonstrate its impartiality. It must not engage in any activities that might conflict with its independence of judgement and integrity. Given that the authorisation of user inspectorates to carry out conformity assessment is an innovation for technical harmonisation at Union level, the Commission shall monitor the application of this measure and evaluate its effects three years after the coming into force of the directive. [Pg.943]

Abstract. Molecular dynamics (MD) simulations of proteins provide descriptions of atomic motions, which allow to relate observable properties of proteins to microscopic processes. Unfortunately, such MD simulations require an enormous amount of computer time and, therefore, are limited to time scales of nanoseconds. We describe first a fast multiple time step structure adapted multipole method (FA-MUSAMM) to speed up the evaluation of the computationally most demanding Coulomb interactions in solvated protein models, secondly an application of this method aiming at a microscopic understanding of single molecule atomic force microscopy experiments, and, thirdly, a new method to predict slow conformational motions at microsecond time scales. [Pg.78]

As an example for an efficient yet quite accurate approximation, in the first part of our contribution we describe a combination of a structure adapted multipole method with a multiple time step scheme (FAMUSAMM — fast multistep structure adapted multipole method) and evaluate its performance. In the second part we present, as a recent application of this method, an MD study of a ligand-receptor unbinding process enforced by single molecule atomic force microscopy. Through comparison of computed unbinding forces with experimental data we evaluate the quality of the simulations. The third part sketches, as a perspective, one way to drastically extend accessible time scales if one restricts oneself to the study of conformational transitions, which arc ubiquitous in proteins and are the elementary steps of many functional conformational motions. [Pg.79]

The second application of the CFTI protocol is the evaluation of the free energy differences between four states of the linear form of the opioid peptide DPDPE in solution. Our primary result is the determination of the free energy differences between the representative stable structures j3c and Pe and the cyclic-like conformer Cyc of linear DPDPE in aqueous solution. These free energy differences, 4.0 kcal/mol between pc and Cyc, and 6.3 kcal/mol between pE and Cyc, reflect the cost of pre-organizing the linear peptide into a conformation conducive for disulfide bond formation. Such a conformational change is a pre-requisite for the chemical reaction of S-S bond formation to proceed. The predicted low population of the cyclic-like structure, which is presumably the biologically active conformer, agrees qualitatively with observed lower potency and different receptor specificity of the linear form relative to the cyclic peptide. [Pg.173]

Fragments used to derive and evaluate parameters for the ketoamide functionality in FK506. (Figure m from J Pranata and PV L Jorgensen 1991. Computational Studies on FK506 Conformational Search and ular Dynamics Simulations in Water. The Journal of the American Chemical Society 113 9483-9493.)... [Pg.248]

There are two problems to consider when calculating 3D pharmacophores. First, unless the molecules are all completely rigid, one must take account of their conformational properties The second problem is to determine which combinations of pharmacophoric groups are common to the molecules and can be positioned in a similar orientation in space. More than one pharmacophore may be possible indeed, some algorithms can generate hundreds of possible pharmacophores, which must then be evaluated to determine which best fits the data. It is important to realise that all of these approaches to finding 3D pharmacophores assume that all of the molecules bind in a common manner to the macromolecule. [Pg.665]

For 4-nitro-5-alkylthiazoles, the prefered conformations of the alkyl substituents relative to the ir-system could be evaluated, and the interactions between alkyl and nitro groups were demonstrated to be negligible. [Pg.84]

From plots of n/c2 versus C2, evaluate M for each of the four polymer fractions. Do the data collected from the two different solvents conform to expectations with respect to slope and intercept values ... [Pg.579]

Once the need for a LIMS has been justified, specifications have been written, and available vendors surveyed, the LIMS selection process begins. Each vendor s product must be evaluated for conformance to the specification and flexibiUty for future modifications. If an adequate solution is not available commercially, consideration must be given to constmcting a custom LIMS solution. This could be done in-house or by contractors. If the custom option is preferred, resources needed for future modifications and maintenance should be factored into the cost. [Pg.520]

Conformance to the standard is achieved by submitting samples to an approved laboratory for evaluation and submitting the laboratory report to the American Automotive Manufacturers Association (AAMA). The approved certificate is sent to the manufacturers with copies to the state and provincial jurisdictions for which the AAMA serves as approvals agent (16). [Pg.526]

Sampling Plan. The first step to assuring accuracy, ie, the conformity of the measured value to the tme or expected value (23), is to obtain a representative sample. Sampling may be the responsibiUty of either production or of QC. A written sampling plan approved by QC should be followed. It is the responsibihty of the QC unit to ensure that samples represent all the material under evaluation. [Pg.367]

Static performance measurements related to positioner/ac tuator operation are conformity, measured accuracy, hysteresis, dead baud, repeatability, and locked stem-pressure gain. Definitions and standardized test procedures for determining these measurements can be found in ISA-S75.13-1989, Method of Evaluating the Performance of Positioners with Analog Input Signals and Pneumatic Output . [Pg.783]


See other pages where Conformity evaluation is mentioned: [Pg.73]    [Pg.140]    [Pg.265]    [Pg.426]    [Pg.44]    [Pg.630]    [Pg.238]    [Pg.73]    [Pg.140]    [Pg.265]    [Pg.426]    [Pg.44]    [Pg.630]    [Pg.238]    [Pg.165]    [Pg.166]    [Pg.483]    [Pg.99]    [Pg.157]    [Pg.248]    [Pg.414]    [Pg.504]    [Pg.533]    [Pg.695]    [Pg.727]    [Pg.649]    [Pg.158]    [Pg.167]    [Pg.168]    [Pg.441]    [Pg.519]    [Pg.58]    [Pg.463]    [Pg.102]    [Pg.2283]    [Pg.79]    [Pg.91]    [Pg.95]    [Pg.119]   
See also in sourсe #XX -- [ Pg.5 ]




SEARCH



© 2024 chempedia.info