Concentration sensitivity, trace analysis

The spatial lesolulion of analylical techniques is also an importanl aspeci of this study. We cannot hope lo deierminc local effects or local concentrations with techniques that ob serve 01 average over large spatial regions, In our example. F lXL, although a sensitive trace analysis nicihtnJ. does not... [Pg.625]

Analysis of Corexit 9527. Corexit 9527 in natural waters can be analyzed. The method is based on the formation of a Z>w(ethylenediamine) copper(II) complex, extraction of the complex into methylisobutylketone, and atomic absorption spectroscopy [1564]. The method is suitable for a concentration range of 2 to 100 mg/liter, with a precision as low as 5% relative to standard deviation for samples in the middle- to high range. Only a small sample volume (10 ml) is required. The sensitivity may be substantially increased for trace analysis by increasing the sample volume. [Pg.306]

On-line SFE coupled to GC or SFC, according to the thermal stability of the analytes, are both very competitive with classical methods of analysis in terms of sensitivity and analysis time. Since all of the extracted analytes are transferred to the GC system, much higher method sensitivities can be obtained. Several modes of operation are possible utilising on-line SFE-GC, including quantitative extraction of all analytes from a sample matrix quantitative extraction and concentration of trace analytes selective extractions at various solvating powers to obtain specific fractions and periodic sampling (multiple-step extractions) of the effluent at various pressures for qualitative characterisation of the sample matrix. [Pg.434]

Fluorescence detectors can be made much more sensitive than uv absorbance detectors for favourable solutes (such as anthracene) the noise equivalent concentration can be as low as 10 12 g cm-3. Because both the excitation wavelength and the detected wavelength can be varied, the detector can be made highly selective, which can be very useful in trace analysis. The response of the detector is linear provided that no more than about 10% of the incident radiation is absorbed by the sample. This results in a linear range of 103-104. [Pg.64]

A stream-splitter may be used at the end of the column to allow the simultaneous detection of eluted components by destructive GC detectors such as an FID. An alternative approach is to monitor the total ion current (TIC) in the mass spectrometer which will vary in the same manner as the response of an FID. The total ion current is the sum of the currents generated by all the fragment ions of a particular compound and is proportional to the instantaneous concentration of that compound in the ionizing chamber of the mass spectrometer. By monitoring the ion current for a selected mass fragment (m/z) value characteristic of a particular compound or group of compounds, detection can be made very selective and often specific. Selected ion monitoring (SIM) is more sensitive than TIC and is therefore particularly useful in trace analysis. [Pg.116]

Multi-element trace analysis is an important prerequisite for the quality assurance of foodstuffs with respect to the characterization of non-essential, toxic and essential (nutrient) elements as pollutions or as mineral elements relevant to health. Contamination with heavy metals such as Cd, Pb or Hg has become a serious problem with increasing environmental (artificial) contamination e.g., due to industrial pollution. The increasing use of inorganic mass spectrometric techniques (especially of ICP-MS) in the analysis of foodstuffs for multi-element analysis of trace elements or the detection of selected elements and species at a low concentration level has resulted from advances in very sensitive and quantitative measurements of metals, metalloids and several non-metals, including their speciation. [Pg.381]

For a detector to be of use in quantitative analysis, the signal output should be linear with concentration for a concentration-sensitive detector and with mass for a mass-sensitive detector. Some detectors have an additional time constant purposely introduced to remove the high-frequency noise. This should always taken into consideration, since a slow detector response can significantly broaden and attenuate chromatographic peaks relative to those actually sensed. Moreover, a versatile detector should have a wide linear dynamic range so that major and trace components can be determined in a single analysis, over a wide concenua-tion range. [Pg.696]

Because of their high sensitivity, fluorescence detectors are particularly useful in trace analysis when either tire sample size is small or the analyte concentration is extremely low. Although fluorescence detectors can become markedly nonlinear at concentrations where absorption detectors are still linear in response, their linear dynamic range is more than adequate for most trace analysis applications. Unfortunately, fluorometric detectors are often susceptible to background fluorescence and quenching effects that can plague all fluorescence measurements. [Pg.698]

Refractive index detectors are useless in gradient elution because it is impossible to match exactly the sample and the reference while the solvent composition is changing. Refractive index detectors are sensitive to changes in pressure and temperature (—0.01 °C). Because of their low sensitivity, refractive index detectors are not useful for trace analysis. They also have a small linear range, spanning only a factor of 500 in solute concentration. The primary appeal of this detector is its nearly universal response to all solutes, including those that have little ultraviolet absorption. [Pg.573]

The triboluminescence of minerals has been studied visually (see the footnotes to Table I) but only a few minerals have been examined spectroscopically. There are a few clear examples of noncentric crystals, such as quartz, whose emission is lightning, sometimes with black body radiation. Most of the triboluminescent minerals appear to have activity and color which is dependent on impurities, as is the case for kunzite, fluorite, sphalerite and probably the alkali halides. Table I attempts to distinguish between fracto-luminescence and deformation luminescence, but the distinctions are not clear cut. A detailed analysis of the structural features of triboluminescent and nontriboluminescent minerals may make it possible to draw conclusions about the nature and concentration of trace impurities that are not obvious from the color or geological site of the crystals. Triboluminescence could be used as an additional method for characterizing minerals in the field, using only the standard rock hammer, with the sensitive human eye as a detector. [Pg.260]


See other pages where Concentration sensitivity, trace analysis is mentioned: [Pg.194]    [Pg.139]    [Pg.79]    [Pg.165]    [Pg.671]    [Pg.262]    [Pg.180]    [Pg.34]    [Pg.437]    [Pg.440]    [Pg.342]    [Pg.689]    [Pg.115]    [Pg.223]    [Pg.101]    [Pg.249]    [Pg.64]    [Pg.87]    [Pg.210]    [Pg.708]    [Pg.37]    [Pg.708]    [Pg.16]    [Pg.189]    [Pg.200]    [Pg.263]    [Pg.268]    [Pg.269]    [Pg.272]    [Pg.282]    [Pg.315]    [Pg.369]    [Pg.371]    [Pg.18]    [Pg.37]    [Pg.338]    [Pg.61]    [Pg.258]   