Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Clusters cluster source

Mass spectra from a carbon cluster ion source show strong magic numbers at C, and C d[136]. This led to the... [Pg.817]

Figure Cl. 1.1. Schematic of a typical laser vaporization supersonic metal cluster source using a pulsed laser and a pulsed helium carrier gas. Figure Cl. 1.1. Schematic of a typical laser vaporization supersonic metal cluster source using a pulsed laser and a pulsed helium carrier gas.
The size distribution of the clusters produced in the cluster source is quite smooth, containing no information about the clusters except their composition. To obtain information about, for example, the relative stability of clusters, it is often useful to heat the clusters. Hot clusters will evaporate atoms and molecules, preferably until a more stable cluster composition is reached that resists further evaporation. This causes an increase in abundance of the particularly stable species (i.e., enhancing the corresponding peak in the mass spectrum, then commonly termed fragmentation spectrum ). Using sufficiently high laser fluences (=50 /iJ/mm ), the clusters can be heated and ionized simultaneously with one laser pulse. [Pg.170]

The pulsed molecular beam cluster source has produced clusters of virtually every material—we have made clusters of even the most refractory transition metals, of group IIIB and IVB elements, and numerous oxides, carbides, and intermetallic alloys of these elements. [Pg.112]

Figure 1. Schematic illustration of the laser-vaporization supersonic cluster source. Just before the peak of an intense He pulse from the nozzle (at left), a weakly focused laser pulse strikes from the rotating metal rod. The hot metal vapor sputtered from the surface is swept down the condensation channel in dense He, where cluster formation occurs through nucleation. The gas pulse expands into vacuum, with a skinned portion to serve as a collimated cluster bean. The deflection magnet is used to measure magnetic properties, while the final chaiber at right is for measurement of the cluster distribution by laser photoionization time-of-flight mass spectroscopy. Figure 1. Schematic illustration of the laser-vaporization supersonic cluster source. Just before the peak of an intense He pulse from the nozzle (at left), a weakly focused laser pulse strikes from the rotating metal rod. The hot metal vapor sputtered from the surface is swept down the condensation channel in dense He, where cluster formation occurs through nucleation. The gas pulse expands into vacuum, with a skinned portion to serve as a collimated cluster bean. The deflection magnet is used to measure magnetic properties, while the final chaiber at right is for measurement of the cluster distribution by laser photoionization time-of-flight mass spectroscopy.
The final probe of molecular clusters is that of selected chemical reactions. The use of probe reactions to study supported cluster catalysts is well established, and we are attempting the development of similar probes of unsupported clusters. The first steps in this direction are the design of a pulsed chemical reactor to go with the pulsed cluster source and the development of criteria for reactions. It is important to recall that at present... [Pg.116]

The cluster reactor is attached to the pulsed cluster source s condensation channel, as shown in Figure 6. (16) To it is attached a high-pressure nozzle from which a helium/hydrocarbon mixture is pulsed into the reactor at a time selected with respect to the production and arrival of the clusters. The effect of turbulent mixing with the reactant pulse perturbs the beam, but clusters and reaction products which survive the travel from the source to the photoionization regime ( 600y sec) and the photoionization process are easily detected. [Pg.120]

Figure 6. Scale-drawn schematic of the cluster reactor in relation to the pulsed cluster source. The letters A-F indicate the various stages of cluster preparation or synthesis, cooling, mixing and reacting, and finally flowing into vacuum toward detection. Figure 6. Scale-drawn schematic of the cluster reactor in relation to the pulsed cluster source. The letters A-F indicate the various stages of cluster preparation or synthesis, cooling, mixing and reacting, and finally flowing into vacuum toward detection.
This overview is organized into several major sections. The first is a description of the cluster source, reactor, and the general mechanisms used to describe the reaction kinetics that will be studied. The next two sections describe the relatively simple reactions of hydrogen, nitrogen, methane, carbon monoxide, and oxygen reactions with a variety of metal clusters, followed by the more complicated dehydrogenation reactions of hydrocarbons with platinum clusters. The last section develops a model to rationalize the observed chemical behavior and describes several predictions that can be made from the model. [Pg.48]

A. Brunelle, D. Touboul and O. Laprevote, Biological tissue imaging with time of flight secondary ion mass spectrometry and cluster ion sources, Journal of Mass Spectrometry, 40,985 999 (2005). [Pg.455]

There are several preparative methods for the production of bare metal clusters including the fast flow reactor (PER), the fast flow tube reactor (FTR), the SIDT (24), the GIB (23), and a supersonic cluster beam source (SCBS) (198). Essentially, all of these methods are similar. The first process is to vaporize the metal sample producing atoms, clusters, and ions. Laser vaporization is generally favored although FAB or FIB may be used. The sample is located in a chamber or a tube and so vaporization generally takes place in a confined environment. An inert gas such as helium may be present in the vaporization source or may be pulsed in after the ionization process. [Pg.394]

Many of the metal cluster anions have been produced by cathode discharge in He doped with Ar and studied in a flow tube reactor. A few clusters have been prepared by laser vaporization using a supersonic cluster beam source and the reac-... [Pg.403]

Neutral clusters from supersonic beam 157 Spectroscopy of neutral clusters 158 Sources of ionic clusters 167 Mass spectrometry of ionic clusters 170... [Pg.147]

Atomic and molecular clusters have been studied for more than fifty years, but the last two decades have seen an increasing interest in new experimental methods for cluster production and analysis. The development and improvement of cluster sources lie at the focal point of the technological advances achieved in the study of gas phase clusters. For what concern the molecules of biological interest, the production and analysis of these molecules both isolated or complexed is made... [Pg.155]

There are many more types of cluster ion sources than there are neutral cluster sources, in part because of the wide variety of ion-forming techniques available and in part because cluster ion sources are often hybrids of established neutral cluster sources and ion-forming environments. Some non-hybrid ion sources which can generate cluster ions include ion sputter, flow tube. Penning... [Pg.156]

As for neutral cluster sources, an ever growing array of techniques are being implemented to generate ionic clusters and measure their properties. Mass spectrometry is useful for quantitative determination of atoms or molecules and... [Pg.167]

Cluster ion sources with different production techniques have been devised [10]. The cluster ions are produced, for instance, by vaporizing the materials using a heated oven, a laser ablation apparatus, or sputtering. Essential features of the cluster ion source are increased intensity and stability of the beam, and control of the mass distribution of the particles. Further development of cluster ion sources is in progress at several facilities [7,11]. [Pg.817]

On the basis of the information described above, some general observations may be made about carbidocarbonyl clusters. The source of the carbon atom, its structural requirements, and its chemical properties are all of interest, as is the effect that it has on the chemistry of the cluster as a whole. [Pg.48]

However, it is rare when all the atoms in an aromatic species are metals. One such system was synthesized in 2001 by A. I. Boldyrev andL.-S. Wang and their colleagues. Using a laser vaporization supersonic cluster source and a Cu/Al... [Pg.154]


See other pages where Clusters cluster source is mentioned: [Pg.2389]    [Pg.2389]    [Pg.2390]    [Pg.170]    [Pg.17]    [Pg.112]    [Pg.110]    [Pg.159]    [Pg.319]    [Pg.48]    [Pg.278]    [Pg.421]    [Pg.147]    [Pg.156]    [Pg.156]    [Pg.171]    [Pg.339]    [Pg.340]    [Pg.120]    [Pg.816]    [Pg.366]    [Pg.25]    [Pg.62]    [Pg.628]    [Pg.19]    [Pg.208]    [Pg.208]   
See also in sourсe #XX -- [ Pg.208 , Pg.209 , Pg.219 ]




SEARCH



Arc cluster ion source

Chiral clusters sources

Cluster source

Cluster source

Ionic clusters sources

Laser Ablation Cluster Source with a Magnetic Sector Mass Selector at the University of California, Santa Barbara

Magnetron Cluster Source with a Lateral TOF Mass Filter at the Universitat Dortmund

Magnetron Cluster Source with a Lateral TOF Mass Filter at the University of Birmingham

Magnetron Cluster Source with a Magnetic Sector at HZB

Magnetron Cluster Source with a Quadrupole Mass Filter at the Toyota Technological Institute

Magnetron cluster source

Metal cluster aggregation sources

Metal cluster source

Metal cluster source clustering

Metal cluster source laser vaporization

Metal cluster source sample

Molecular clusters sources

Pulsed arc cluster ion source

Pulsed cluster source

Supersonic cluster beam source

© 2024 chempedia.info