Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chemical analysis system, requirements

Initial experiments have demonstrated the feasibility of flow manifolds having a stacked configuration for chemical analysis systems A substantial reduction in system size may be accomplished when micromachined silicon elements are employed Implementation of the concept of merging zones of sample and reagents and the valveless injection scheme result in more efficient consumption of reagents In order to benefit fully from the possible advantages of miniaturization, a carefril design of the components as well as the analysis methods is required... [Pg.189]

In order to produce a complete chemical analysis system, miniaturisation of both extraction and clean-up stages is required, and work in this area is in progress. [Pg.298]

The classical microscopic description of molecular processes leads to a mathematical model in terms of Hamiltonian differential equations. In principle, the discretization of such systems permits a simulation of the dynamics. However, as will be worked out below in Section 2, both forward and backward numerical analysis restrict such simulations to only short time spans and to comparatively small discretization steps. Fortunately, most questions of chemical relevance just require the computation of averages of physical observables, of stable conformations or of conformational changes. The computation of averages is usually performed on a statistical physics basis. In the subsequent Section 3 we advocate a new computational approach on the basis of the mathematical theory of dynamical systems we directly solve a... [Pg.98]

Of course, the term proven efficacy is central to any resource investment in this area. Basic information on time and dose responses in humans to complex foods rich in carotenoids (and other phytochemicals) is pitifully small. Much of our information is based upon inadequate databases derived from chemical analysis, in vitro models that have not been properly evaluated or validated, and short-term, high-dose human studies. Future research progress requires much more rigorous debate on the experimental systems employed... [Pg.123]

Major drivers for using micro-channel chip systems for chemical analysis are low reagent consumption, low energy consumption, high reliability, good robustness also in the hands of personnel not trained in analytical chemistry, and low maintenance requirements [30]. [Pg.105]

Unfortunately, the analysis of chemical absorption is far more complex than physical absorption. The vapor-liquid equilibrium behavior cannot be approximated by Henry s Law or any of the methods described in Chapter 4. Also, different chemical compounds in the gas mixture can become involved in competing reactions. This means that simple methods like the Kremser equation no longer apply and complex simulation software is required to model chemical absorption systems such as the absorption of H2S and C02 in monoethanolamine. This is outside the scope of this text. [Pg.184]

Perhaps the most obvious method of studying kinetic systems is to periodically withdraw samples from the system and to subject them to chemical analysis. When the sample is withdrawn, however, one is immediately faced with a problem. The reaction will proceed just as well in the test sample as it will in the original reaction medium. Since the analysis will require a certain amount of time, regardless of the technique used, it is evident that if one is to obtain a true measurement of the system composition at the time the sample was taken, the reaction must somehow be quenched or inhibited at the moment the sample is taken. The quenching process may involve sudden cooling to stop the reaction, or it may consist of elimination of one of the reactants. In the latter case, the concentration of a reactant may be reduced rapidly by precipitation or by fast quantitative reaction with another material that is added to the sample mixture. This material may then be back-titrated. For example, reactions between iodine and various reducing agents can be quenched by addition of a suitably buffered arsenite solution. [Pg.38]

The first steps in unravelling the details of an unknown system frequently involve the identification of its constituents by qualitative chemical analysis. Follow-up investigations usually require structural information and quantitative measurements. This pattern appears in such diverse areas as the formulation of new drugs, the examination of meteorites, and studies on the results of heavy ion bombardment by nuclear physicists. [Pg.613]

ETEM is thus used as a nanolaboratory with multi-probe measurements. Design of novel reactions and nanosynthesis are possible. The structure and chemistry of dynamic catalysts are revealed by atomic imaging, ED, and chemical analysis (via PEELS/GIF), while the sample is immersed in controlled gas atmospheres at the operating temperature. The analysis of oxidation state in intermediate phases of the reaction and, in principle, EXELFS studies are possible. In many applications, the size and subsurface location of particles require the use of the dynamic STEM system (integrated with ETEM), with complementary methods for chemical and crystallographic analyses. [Pg.220]

Predicting sorption coefficients and hence the mobility of organic pollutants in aqueous-solid systems requires complete knowledge and analysis of various physical and chemical properties of such pollutants. This includes properties such as solubility, equilibrium vapor pressure, Henry s law constant, partition coefficient, as well as pKa and pKb values. Such properties can initially help determine the sorption-desorption behavior of organic pollutants once they are released, directly and/or indirectly, to the aqueous environment and then are in direct contact with solid phases. The following sections briefly summarize these properties. [Pg.246]

The first edition of Automatic Chemical Analysis was published in 1974 and was written in coUahoration with the late Jim Foreman. It was well received and became a set course book in many universities. Its aim was to provide a basic grounding in the subject and to cover the wider issues of economic assessments, educational requirements and specification of systems. TTiere are now other books on laboratory automation in print [1,2], but none of these will help potential users of automation to evaluate the economic viability of a project indeed, they may even put them off. The other hooks are scholarly rather than practical. [Pg.8]

Exact analysis of sialic acid is required in biologieal experiments where the biological role of sialic acid is frequently studied with the aid of sialidases, and the amount of sialic acids released is determined. This is also important for periodate oxidation studies on biological systems, where modification of sialic acids by periodate is only assumed, but chemical analysis of this effect by isolation and analysis of the modified sialic acids is seldom performed. These uncertainties in determinations of sialic acid can be overcome by the purification procedures already described. Furthermore, it must be stressed that unequivocal determination of the structure of a sialic acid, especially... [Pg.152]


See other pages where Chemical analysis system, requirements is mentioned: [Pg.702]    [Pg.2]    [Pg.47]    [Pg.650]    [Pg.121]    [Pg.191]    [Pg.353]    [Pg.419]    [Pg.401]    [Pg.133]    [Pg.104]    [Pg.151]    [Pg.238]    [Pg.304]    [Pg.174]    [Pg.13]    [Pg.38]    [Pg.385]    [Pg.503]    [Pg.274]    [Pg.40]    [Pg.83]    [Pg.465]    [Pg.19]    [Pg.1253]    [Pg.156]    [Pg.11]    [Pg.3]    [Pg.277]    [Pg.270]    [Pg.76]    [Pg.79]    [Pg.94]    [Pg.1253]    [Pg.127]    [Pg.299]    [Pg.174]    [Pg.46]   
See also in sourсe #XX -- [ Pg.2 , Pg.15 ]




SEARCH



Chemical requirements

Requirement analysis

System requirement

© 2024 chempedia.info