Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Stack configuration

The environmental appHcations of infrared spectrometry are many and varied. Many appHcations at industrial sites are analogous to those for on-line process analysis waste streams and recycling processes can be monitored in the same way. Commercial infrared stack-gas monitors are based on either an extractive probe attached to a long-path gas ceU or an open-path (across stack) configuration (69). Stack plume and flare monitoring can be done externally... [Pg.201]

SOFC are produced with either tubular or planar stack configurations investments for planar design are a rough estimate, as no prototypes exist. Specific investments for PAFC are in the range 4000- 4500/kW (IEA, 2007). For further fuel-cell R D needs see IEA (2005). [Pg.359]

Fig. 4.61. Stacking of MCPs to increase gain. From left single MCP, Chevron plate, and z-stack configuration. Note the loss of spacial resolution upon stacking. Fig. 4.61. Stacking of MCPs to increase gain. From left single MCP, Chevron plate, and z-stack configuration. Note the loss of spacial resolution upon stacking.
System A in Figure 9-20 is composed of a single stack. Three stacks are arranged in series in system B. System C features many, or "n," stacks configured in series. In all three systems, the voltage of each stack corresponds to reactant concentrations at its outlet. [Pg.268]

Computer simulations have demonstrated that a combined cycle system with MCFC stacks networked in series is significantly more efficient than an identical system with MCFC stacks configured in parallel. [Pg.273]

Stability constant of complexes, measurement by chomatography, 276 Stack configuration, 137 Standard deviations, 3 Stetionary phases, bonded hydrocaibona-ceous, 121... [Pg.172]

An overall DMFC stack energy conversion efficiency of 35% was achieved over a range of stack operating conditions of 0.46-0.57 V per cell. An extended life test over llOOh on a five-cell stack made of identical cell components and stack configurations was also performed. [Pg.50]

An extended stack life test was performed on a five-cell stack built with cell components and stack configuration identical with those of the 30-cell stack. The... [Pg.66]

Fig. 7.2 Sandwich (or stacked) configurations placed in an electrolyte solution (a) p-n type, (b) semiconductor-metal type photochemical diodes. Both p-type and n-type semiconductors are provided with ohmic contacts. In p-n type light is incident from both directions and ohmic contacts are connected through metal contacts. Fig. 7.2 Sandwich (or stacked) configurations placed in an electrolyte solution (a) p-n type, (b) semiconductor-metal type photochemical diodes. Both p-type and n-type semiconductors are provided with ohmic contacts. In p-n type light is incident from both directions and ohmic contacts are connected through metal contacts.
In conclusion, a typical time of 300 fs has been found for the excited-state intramolecular double proton transfer in TAB and DAC. The proton transfer dynamics is not influenced by aggregation. In addition, a vibronic cooling time of 20 ps has been measured for the probe molecules in the molecular and stacked configurations. Finally, aggregation is found to almost completely hamper the rotational diffusion motions of the molecules during the fluorescence state lifetime of 4 ns. [Pg.502]

Static Pressure Drop—The reduction of air movement through the tower resulting from resistance of internal components such as air-intake louvers, fill packing, water distribution system, internal supporting beams, drift eliminators and fan stack configuration. [Pg.9]

To model a complete stack, which may be constituted of more than 1000 cells, it is necessary to adopt a different approach. In this chapter a finite difference model is presented. Only energy equation and current conservation are solved. This allows one to examine possible improvements in the stack configuration design that can be achieved by taking advantage of the relation between temperature and elec-tronic/ionic resistivity, heat transfer and chemical reactions, etc. In addition, this model can be used for analyzing the effects of possible anomalies and performance degradation. [Pg.214]

Fig. 2 Molecular structure of a model F8BT(top) TFB(bottom) polymer heterojunction in the eclipsed stacking configuration, see also Fig. 3. In the actual polymer, the residues are R = C8Hi2 in the calculations reported here, R = H was used (Adapted from Ref. [43]). Fig. 2 Molecular structure of a model F8BT(top) TFB(bottom) polymer heterojunction in the eclipsed stacking configuration, see also Fig. 3. In the actual polymer, the residues are R = C8Hi2 in the calculations reported here, R = H was used (Adapted from Ref. [43]).
Taking into account commercial objectives and goals, a Teledyne Perry NG2000 stack configuration was chosen to meet requirements for the 7-kW gt power plant. Two 60-cell stacks rated at 5.0-kWgi.oss (Figures 1 and 2), electrically connected in parallel, will be utilized to meet total power demands. [Pg.286]


See other pages where Stack configuration is mentioned: [Pg.582]    [Pg.1805]    [Pg.562]    [Pg.333]    [Pg.252]    [Pg.314]    [Pg.100]    [Pg.399]    [Pg.265]    [Pg.345]    [Pg.6]    [Pg.54]    [Pg.1565]    [Pg.144]    [Pg.46]    [Pg.81]    [Pg.314]    [Pg.213]    [Pg.26]    [Pg.195]    [Pg.216]    [Pg.282]    [Pg.322]    [Pg.53]    [Pg.376]    [Pg.405]    [Pg.205]    [Pg.565]    [Pg.118]    [Pg.448]    [Pg.76]    [Pg.1809]    [Pg.208]   
See also in sourсe #XX -- [ Pg.413 ]

See also in sourсe #XX -- [ Pg.132 ]

See also in sourсe #XX -- [ Pg.152 , Pg.153 , Pg.154 ]




SEARCH



Stack Configuration and Sealing

© 2024 chempedia.info