Capillary wall coated open tubular

With packed columns, losses through adsorption and peak tailing are greater (due to the larger surface area) than with capillary wall coated open tubular columns. The latter is preferred because it provides the required inertness, high resolution, and sharp signals. [Pg.355]

Before discussing column preparation procedures a few comments on nomenclature are in order. Open tubular columns are also widely known as capillary columns. The characteristic feature of these columns is their openness, which provides an unrestricted gas path through the column. Thus open tubular colximn rather than capillary column is a more apt description. However, both descriptions appear frequently in the literature and can be emsidered interchangeable. The type of columns discussed so far are also known as wall-coated open tubular columns (WCOT). Here the liquid phase is deposited directly onto the column wall without the inclusion of any additive that might be considered as... [Pg.590]

These have now been superseded by capillary columns, which offer greatly improved separation efficiency. Fused silica capillary tubes are used which have internal diameters ranging from 0.1 mm (small bore) to 0.53 mm (large bore) with typical lengths in excess of 20 m. The wall-coated open tubular (WCOT) columns have the internal surface of the tube coated with the liquid (stationary) phase and no particulate supporting medium is required. An alternative form of column is the porous-layer open tubular (PLOT) column, which has an internal coating of an adsorbent such as alumina (aluminium oxide) and various coatings. Microlitre sample volumes are used with these capillary columns and the injection port usually incorporates a stream splitter. [Pg.119]

Vindevogel, J., and Sandra, P. (1994). On the possibility of performing chiral wall-coated open-tubular electrochromatography in 50 pm internal diameter capillaries. Electrophoresis 15, 842-847. [Pg.515]

The term A is related to the flow profile of the mobile phase as it traverses the stationary phase. The size of the stationary phase particles, their dimensional distribution, and the uniformity of the packing are responsible for a preferential path and add mainly to the improper exchange of solute between the two phases. This phenomenon is the result of Eddy diffusion or turbulent diffusion, considered to be non-important in liquid chromatography or absent by definition in capillary columns, and WCOT (wall coated open tubular) in gas phase chromatography (Golay s equation without term A, cf. 2.5). [Pg.18]

Standards with a poor UV chromophore (4-methyl-2-pentanone, 1-chlorododecane, and stearic acid) were analyzed on a Perkin-Elmer 3920 gas chromatograph with a flame ionization detector and a 30-m SE-54 wall-coated open tubular (WCOT) fused-silica capillary column (J W Scientific). The injector temperature was 200 °C the detector interface temperature was 280 °C. The carrier gas was He at 16.5 lb/in.2, and the makeup gas was nitrogen at a flow of 40 cm3/min. Splitless l-/zL injections of the 25,000 1 concentrates were made by starting with an oven temperature of 45 °C and the oven door open after 2.75 min, the oven door was closed and the temperature was programmed at 4 °C/min to 280 °C, which was held for 8 min. The syringe was kept in the injection port for 15 s after injection. [Pg.547]

The column is the most critical part of a GC system and is chosen based on the nature of the analysis. There are two types of columns available for GC analysis packed columns and capillary (e.g., wall coated open tubular WCOT) columns. A packed column is not the primary choice for today s routine analysis of fatty acid composition due to its low resolution and requirement for large amounts of sample. Compared to a packed column, a capillary column needs far less sample and is able to achieve superior resolution. [Pg.446]

Suzuki et al. [819] studied the determination of chlorinated insecticides in river and surface waters using high resolution electron capture gas chromatography with glass capillary columns. They compared resolution efficiencies of organochlorine insecticides and their related compounds with wall-coated open tubular (WCOT) and support-coated open tubular (SCOT) glass capillary columns with those of conventional... [Pg.275]

In particular, we can choose between open (capillary) columns and packed columns. A wall coated open tubular (WCOT) column has a much smaller phase ratio than a packed column, due to the small surface area of the wall. [Pg.6]

Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) analyses GC analyses are performed on a WCOT (wall-coated open tubular) polydimethylsiloxane fused silica capillary column (1 fim film thickness, 50m x 0 32mm ID ) Shorter columns for example 25m, or columns with thinner films, for example 0 2/im, may also be used successfully Injection of the silylated sample (2/d) is performed with a moving needle-type injector, other types of capillary GC injection systems may be used after optimization of the concentration and amount of sample to be injected With a 50-m capillary... [Pg.337]

Gas chromatography and gas chromatography/mass spectrometry were employed to identify and quantitate individual molecular components. Both 25 and 50 meter glass support coated open tubular (SCOT) and fused silica wall coated open tubular (WCOT) capillary columns (SE.30, BP.l and BP.5 phases) were used with H2 as a carrier gas and F.I.D. detection. Acidic components were derivitized (BF3/methanol) to their methyl esters and hydroxyl groups to their silyl ethers (N,0-bis-(trimethylsilyl)trifluoroacetamide) in order to improve chromatographic separation. Carbon Preference Indices (CPI) were calculated using the equation -... [Pg.110]

Open tubular columns are simply capillary tubes in which the inside of the column wall is used as the support for the liquid phase. These wall-coated open tubular columns (WCOT) have the stationary phase distributed in the form of a thin film on the inside surface of the open capillary tube, the walls thus serving as the support. In order to reduce the thickness of the liquid phase film, a porous layer may be formed on the inside wall of the capillary tubing and then coated with the liquid phase to produce a support-coated open tubular column (SCOT). Porous-layer open tubular colunms (PLOT) are similar to SCOT colunms, the difference being that in the former, the stationary phase is deposited on fine crystalline particles or glass powder which is adsorbed onto the walls of the tube. In both cases, the available surface area of the wall is increased, and allows an increased amount of liquid phase to be accommodated in the same length and diameter of tubing. The whisker-walled (WW) colunm consists of whiskers chemically etched on the surface of the wall, which also result in a significant increase in the available surface area. Wall-coated, porous-layer, and support-coated capillary columns are all available as whisker-walled, i.e., WWCOT, WWPLOT, and WWSCOT, respectively. [Pg.472]

Two types of columns are used in SFC packed columns containing solid particles of small inner diameter or wall-coated open-tubular columns (WCOT), usually called just capillary columns. Packed columns have been preferred when capacity is the most relevant issue capillary columns are selected when efficiency is the goal. [Pg.1550]

Wall-coated open tubular (WCOT) column A capillary column coated with a thin layer of stationary phase. [Pg.1120]

According to the tjT)e and form of the coating, capillary column may be subdivided into wall-coated open tubular (WCOT) type, porous-layer open tubular (PLOT) type, and support coated open tubular type. The most... [Pg.79]

There are three types of opemtubular columns. Wall-coated open-tubular (WCOT) columns have a thin liquid film coated on and supported by the walls of the capillary. The walls are coated by slowly passing a dilute solution of the liquid... [Pg.579]

A good comparison of packed and glass capillary column separations was demonstrated by Grob (8). The two chromatograms shown in Figure 6 are of the same lake water extract, run on the same stationary phase (OV-1). Packed and wall coated open tubular (WCOT) columns and methods are compared in Table I. [Pg.116]


See other pages where Capillary wall coated open tubular is mentioned: [Pg.676]    [Pg.676]    [Pg.106]    [Pg.107]    [Pg.315]    [Pg.58]    [Pg.99]    [Pg.106]    [Pg.62]    [Pg.710]    [Pg.202]    [Pg.3]    [Pg.154]    [Pg.212]    [Pg.672]    [Pg.452]    [Pg.99]    [Pg.168]    [Pg.266]    [Pg.331]    [Pg.652]    [Pg.629]    [Pg.7]    [Pg.245]    [Pg.1107]    [Pg.1676]    [Pg.261]    [Pg.150]    [Pg.959]    [Pg.41]    [Pg.119]    [Pg.141]    [Pg.1437]   