Capillary column stabilization

The temperature of the sample compartment and capillary column should be tested for both accuracy and stability at the lowest and highest settings that are expected to be used. Typically these would be between 10 and 60°C with an accuracy of 1°C for the sample compartment and between 15 and 50°C with an accuracy of +2°C for the capillary column. [Pg.178]

In general the preparation of a polymer monolithic rod is performed as a multi-step procedure (Figure 11). Generally, the stages involved are pre-treatment and preparation of the monolithic matrix by polymerization and derivatization or functionalization. Pre-treatment of the bare capillary is sometimes needed in order to obtain good physical stability. Most columns are therefore polymerized in silanized columns. The capillary column is first washed with a strong alkaline solution such as 1.0 M sodium hydroxide so that the siloxane groups at... [Pg.456]

Chromatographic Resolution. To optimize column-coating conditions and operating parameters glass capillary columns coated with various silicone-based stationary phases were tested with difficult-to-separate groups of PAH standards and Complex samples. The SE5 -coated columns performed excellently with respect to separation efficiency, column bleed and long-term stability. Other observers have had similar results with this... [Pg.358]

Gas chromatographic methods have been successfully used for the determination of penicillin molecules bearing neutral side-chains in milk and tissues (95, 97), but cannot be used for amphoteric -lactams. Gas chromatography of penicillin residues is further complicated by the necessity for derivatization with diazomethane. This derivatization step is particularly important because it not only leads to formation of the volatile penicillin methyl esters but also improves their chromatographic properties (thermal stability and decreased polarity). Using a fused-silica capillary column in connection with a thermionic nitrogen-selective detector, excellent separation and sensitivity figures were obtained. [Pg.924]

Both capillary and packed columns are available for use. Much of recent interest in SFC is based on the stability and high efficiencies capillary columns. Because these columns are deactivated, the elution analytes with unmodified carbon dioxide is possible. Some of the comm stationary phases available as capillary columns are as follows ... [Pg.126]

Cole [18] found that in the identification of kerosine and aviation fuels, the usual packed columns provided sufficient detail only up to Ci3 //-alkane, a range readily altered by evaporation effects. A suitable capillary column was developed which revealed extra detail of minor components above Ci3 u-alkane, and consisted of a 45mx0.25mm stainless steel column coated with OV-101. This gave satisfactory resolution and stability in the 50-310°C temperature range. [Pg.254]

Usually, two 100 cm long monolithic columns were prepared from the same reaction mixture, and two-four 33 cm long columns were obtained from the two 100 cm long silica capillaries containing silica monolith. The capillary columns (100 pm I.D.) showed 10,000-12,000 theoretical plates for the effective length of 25 cm under optimized conditions in a pressure-driven mode, and up to 40,000 plates in the CEC mode. The use of smaller-sized capillaries, e.g., 50 pm I.D., and the modification of the preparation method of mesopores, resulted in a monolithic silica column of higher efficiency and higher mechanical stability [25-27], Under optimized conditions, 80,000 plates were obtained with a 25 cm column in CEC. [Pg.183]


See other pages where Capillary column stabilization is mentioned: [Pg.423]    [Pg.10]    [Pg.316]    [Pg.37]    [Pg.84]    [Pg.89]    [Pg.602]    [Pg.602]    [Pg.640]    [Pg.669]    [Pg.690]    [Pg.693]    [Pg.696]    [Pg.910]    [Pg.198]    [Pg.238]    [Pg.487]    [Pg.155]    [Pg.157]    [Pg.34]    [Pg.106]    [Pg.91]    [Pg.3]    [Pg.451]    [Pg.38]    [Pg.61]    [Pg.673]    [Pg.446]    [Pg.335]    [Pg.70]    [Pg.34]    [Pg.67]    [Pg.422]    [Pg.26]    [Pg.50]    [Pg.45]    [Pg.45]    [Pg.369]    [Pg.89]    [Pg.52]    [Pg.61]    [Pg.161]    [Pg.181]   
See also in sourсe #XX -- [ Pg.157 ]




SEARCH



Capillary column columns)

Capillary columns