Silica capillary

The use of the cationic micellar agent CTAB (50 mM) in phosphate-borate buffer (10 mM of each salt), pH 8.6, with 10% acetonitrile was preferred because of a faster separation (about 15 min) of heroin and related substances. Because the cationic surfactant, which coats the capillary silica wall with a positively charged layer, reverses the electroosmotic flow (EOF), the voltage (-15 kV) must be applied with a reversed polarity (with the cathode at the injection point). Detection was by UV absorption at 280 nm. [Pg.167]

Co(acac)3 is frequently used as a probe for enantioseparation efficiency of col-umns " . A monolytic capillary silica gel column was functionalized with methacrylate residues in two steps, as shown in equation and then it was impregnated with cellulose or amylose (51a, b) which was modified so that 30% of the R groups were the methacrylate group 52 and the rest was identical to R (53). For further stability of the column, the polymeric modifier was immobilized on the silica gel by in situ copolymerization with an olefinic monomer such as 2,3-dimethylbutadiene. Only the column containing cellulose modified as in 51a was able to separate the Co(acac)3 racemic mixture, whereas neither cellulose nor amylose modified as in 51b did, although they were successful in resolving other racemic mixtures ° °. ... [Pg.712]

Finally, it is interesting to mention that capillary monolithic columns have also started to be used in gas adsorption chromatography [425, 426]. Poly-DVB monohth obtained in the presence of l.Svol of dodecanol-toluene mixtures possesses good separating power however, its efficiency (the theoretical plate height) still yields by a factor of 3-10 to that of traditional open capillary columns. On the other hand, the theoretical plate height for a similar monolith prepared for use in liquid chromatography proved to be comparable with that of conventional capillary silica-packed column [427]. [Pg.146]

Hirata and Nakata Styrene oligomers, oligomeric ethers, polysiloxanes, alkyl phthalates Packed capillary silica ODS Hexane-ethanol Hexane-methanol uv Styrene-oligomers up to 9000 MM... [Pg.233]

Adsorbents such as some silica gels and types of carbons and zeolites have pores of the order of molecular dimensions, that is, from several up to 10-15 A in diameter. Adsorption in such pores is not readily treated as a capillary condensation phenomenon—in fact, there is typically no hysteresis loop. What happens physically is that as multilayer adsorption develops, the pore becomes filled by a meeting of the adsorbed films from opposing walls. Pores showing this type of adsorption behavior have come to be called micropores—a conventional definition is that micropore diameters are of width not exceeding 20 A (larger pores are called mesopores), see Ref. 221a. [Pg.669]

It was noted earlier (p. 115) that the upward swing in the Type IV isotherm characteristic of capillary condensation not infrequently commences in the region prior to the lower closure point of the hysteresis loop. This feature can be detected by means of an a,-plot or a comparison plot (p. 100). Thus Fig. 3.25(a) shows the nitrogen isotherm and Fig. 3.25(h) the a,-plot for a particular silica gel the isotherm is clearly of Type IV and the closure point is situated around 0 4p° the a,-plot shows an upward swing commencing at a = 0-73, corresponding to relative pressures of 013 and therefore well below the closure point. [Pg.160]

Capillary Columns Capillary, or open tubular columns are constructed from fused silica coated with a protective polymer. Columns may be up to 100 m in length with an internal diameter of approximately 150-300 )J,m (Figure 12.17). Larger bore columns of 530 )J,m, called megabore columns, also are available. [Pg.564]

Microcolumns use less solvent and, because the sample is diluted to a lesser extent, produce larger signals at the detector. These columns are made from fused silica capillaries with internal diameters of 44—200 pm and lengths of up to several meters. Microcolumns packed with 3-5-pm particles have been prepared with column efficiencies of up to 250,000 theoretical plates. [Pg.579]

Capillary Tubes Figure 12.42 shows a cross section of a typical capillary tube. Most capillary tubes are made from fused silica coated with a 20-35-)J,m layer of poly-imide to give it mechanical strength. The inner diameter is typically 25-75 )J,m, which is smaller than that for a capillary GC column, with an outer diameter of 200-375 )J,m. [Pg.601]

Capillary Electrochromatography Another approach to separating neutral species is capillary electrochromatography (CEC). In this technique the capillary tubing is packed with 1.5-3-pm silica particles coated with a bonded, nonpolar stationary phase. Neutral species separate based on their ability to partition between the stationary phase and the buffer solution (which, due to electroosmotic flow, is the mobile phase). Separations are similar to the analogous HPLC separation, but without the need for high-pressure pumps, furthermore, efficiency in CEC is better than in HPLC, with shorter analysis times. [Pg.607]

Caffeine in coffee, tea, and soda is determined by a solid-phase microextraction using an uncoated silica fiber, followed by a GC analysis using a capillary SPB-5 column with an MS detector. Standard solutions are spiked with G3 caffeine as an internal standard. [Pg.612]

One of the earliest models is illustrated in Figure 13.3, which clearly shows the principles used in later improvements. The LC effluent was pumped along a length of silica capillary tubing inside... [Pg.83]

We have developed the method for quantitative analysis of urinary albumin with CE. A capillary electrophoresis systems Nanophor 01 (Institute of Analytical Instmmentation, Russian Academy of Sciences, Saint-Petersburg) equipped with a UV-detector was used to determine analyte. Separation was achieved using 45 cmx30 p.m I.D. fused silica capillary column with UV-detection at 214 nm. [Pg.100]

It is clear that the separation ratio is simply the ratio of the distribution coefficients of the two solutes, which only depend on the operating temperature and the nature of the two phases. More importantly, they are independent of the mobile phase flow rate and the phase ratio of the column. This means, for example, that the same separation ratios will be obtained for two solutes chromatographed on either a packed column or a capillary column, providing the temperature is the same and the same phase system is employed. This does, however, assume that there are no exclusion effects from the support or stationary phase. If the support or stationary phase is porous, as, for example, silica gel or silica gel based materials, and a pair of solutes differ in size, then the stationary phase available to one solute may not be available to the other. In which case, unless both stationary phases have exactly the same pore distribution, if separated on another column, the separation ratios may not be the same, even if the same phase system and temperature are employed. This will become more evident when the measurement of dead volume is discussed and the importance of pore distribution is considered. [Pg.28]

It is a common procedure to assume certain conditions for the chromatographic system and operating conditions and, as a result, simplify equations (20) and (21). However, in many cases the assumptions can easily be over-optimistic, to say the least. It is necessary, therefore, to carefully consider the conditions that may allow such simplifying procedures and take steps to ensure that such conditions are carefully met when such expressions are used in practice. Now, the relative magnitudes of the resistance to mass transfer terms will vary with the type of columns (packed or capillary), the type of chromatography (GC or LC) and the type of particle, i.e., porous or microporous (diatomaceous support or silica gel). [Pg.278]

A theoretical model whereby maximum peak capacity could be achieved by the use of 3-D planar chromatographic separation was proposed by Guiochon and coworkers (23-27). Unfortunately, until now, because of technical problems, this idea could not be realized in practice. Very recently, however, a special stationary phase, namely Empore silica TLC sheets, has now become available for realization of 3-D PC. This stationary phase, developed as a new separation medium for planar chromatography, contains silica entrapped in an inert matrix of polytetrafluoroethy-lene (PTFE) microfibrils. It has been established that the separating power is only ca. 60% of that of conventional TLC (28) this has been attributed to the very slow solvent migration velocity resulting from capillary action. [Pg.184]

The mechanism by which analytes are transported in a non-discriminate manner (i.e. via bulk flow) in an electrophoresis capillary is termed electroosmosis. Eigure 9.1 depicts the inside of a fused silica capillary and illustrates the source that supports electroosmotic flow. Adjacent to the negatively charged capillary wall are specifically adsorbed counterions, which make up the fairly immobile Stern layer. The excess ions just outside the Stern layer form the diffuse layer, which is mobile under the influence of an electric field. The substantial frictional forces between molecules in solution allow for the movement of the diffuse layer to pull the bulk... [Pg.198]

Figure 9.1 The hydrated inner surface of a fused silica capillary is where electi oosmotic flow originates. Figure 9.1 The hydrated inner surface of a fused silica capillary is where electi oosmotic flow originates.
Figure 9.12 Schematic diagram of the silica sheath electrospray needle used to interface capillary zone electi ophoresis with a mass spectrometer. Figure 9.12 Schematic diagram of the silica sheath electrospray needle used to interface capillary zone electi ophoresis with a mass spectrometer.

See other pages where Silica capillary is mentioned: [Pg.459]    [Pg.40]    [Pg.377]    [Pg.6]    [Pg.197]    [Pg.198]    [Pg.459]    [Pg.40]    [Pg.377]    [Pg.6]    [Pg.197]    [Pg.198]    [Pg.78]    [Pg.364]    [Pg.112]    [Pg.150]    [Pg.260]    [Pg.567]    [Pg.598]    [Pg.546]    [Pg.189]    [Pg.18]    [Pg.286]    [Pg.286]    [Pg.632]    [Pg.4]    [Pg.35]    [Pg.36]    [Pg.84]    [Pg.191]    [Pg.207]    [Pg.212]    [Pg.219]    [Pg.219]    [Pg.220]    [Pg.220]    [Pg.221]    [Pg.221]   