Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Capillary column composition

Glycosyl-residue compositions were determined by GC-CIMS analysis of the per-O-trimethylsilylated methyl glycosides [23] separated on a fused-silicaDB-1 capillary column. The identity of each peak was confirmed by CIMS on a HP-5989 MS Engine (Hewlett-Packard). [Pg.70]

The selection of the column type is mainly determined by the composition of the sample. In general open-tubular (capillary) columns are preferred for low-density (gas-like) SFC, whereas packed columns are most useful for high-density (liquid-like) SFC. Open-tubular columns can provide a much larger number of theoretical plates than packed columns for the same pressure drop. Volumetric flow-rates are much higher in packed column SFC (pSFC) than in open-tubular column SFC (cSFC), which makes injection and flow control less problematic. [Pg.207]

The narrow range of organic modifiers required to elute and desorb polypeptides from the reversed-phase column packing material accounts for the separation of polypeptides from a short C18 capillary column. Because polypeptide elution and separation depend on the accuracy of solvent composition in gradient nano LC, it is very important to use a system that can precisely control the LC modifier concentration even at low percents of organic modifiers in chromatographic elution compositions. [Pg.361]

This technology was extended to the preparation of chiral capillary columns [ 138 -141 ]. For example, enantioselective columns were prepared using a simple copolymerization of mixtures of O-[2-(methacryloyloxy)ethylcarbamoyl]-10,11-dihydro quinidine, ethylene dimethacrylate, and 2-hydroxyethyl methacrylate in the presence of mixture of cyclohexanol and 1-dodecanol as porogenic solvents. The porous properties of the monolithic columns can easily be controlled through changes in the composition of this binary solvent. Very high column efficiencies of 250,000 plates/m and good selectivities were achieved for the separations of numerous enantiomers [140]. [Pg.35]

Determined by GC on an HP-5 or a Supelco Simplicity 1 fused-silica capillary column. The percentage compositions were obtained from electronic integration measurements, without taking into account relative response factors. [Pg.374]

A principal components multivariate statistical approach (SIMCA) was evaluated and applied to interpretation of isomer specific analysis of polychlorinated biphenyls (PCBs) using both a microcomputer and a main frame computer. Capillary column gas chromatography was employed for separation and detection of 69 individual PCB isomers. Computer programs were written in AMSII MUMPS to provide a laboratory data base for data manipulation. This data base greatly assisted the analysts in calculating isomer concentrations and data management. Applications of SIMCA for quality control, classification, and estimation of the composition of multi-Aroclor mixtures are described for characterization and study of complex environmental residues. [Pg.195]

More than 100 compounds are released in the atmosphere of urban areas by automobiles, and there is a close relation between the atmospheric hydrocarbon composition and the composition of gasolines and automobile exhausts. The full range of compositions of gasolines has been reported by Sanders and Maynard.They identified 180 of the 240 compounds separated by capillary-column gas chromatography. Detailed fiiel compositions were reported by other investigators, and exhaust hydrocarbon compositions were reported by Neligan et a/.,McEwen, and, more recently. Papa et Jacobs, ... [Pg.95]

K. D. R. Setchell, J. A. Ives, G. C. Cashmore and A. M. Lawson, On the homogeneity of stools with respect to bile-acid composition and normal day-to-day variations A detailed qualitative and quantitative study using capillary column gas chromatography-mass spectrometry, Clin. Chim. Acta, 1987, 162, 257. [Pg.95]

Ravid U, Putievsky E, Katzir I, Ikan R, Determination of the enantiomeric composition of terpinen-4-ol in essential oils using a permethylated 3-cyclodextrin coated chiral capillary column. Flavour Fragr/7 49—52, 1992. [Pg.186]

Elemental composition H 5.92%, S 94.08. Hydrogen sulfide may be distinguished by its characteristic odor. The gas turns a paper soaked in lead acetate solution black. Many infrared sensors are commercially available for in-situ measurements of H2S. It may be monitored semiquantitatively by Draeger tubes. It also may be analyzed by GC following trapping over molecular sieves and thermal desorption. Either a flame photometric detector or a sulfur chemiluminescence detector may be used for GC analysis. It may be separated on a capillary column such as Carboxen 1006 PLOT or SPB-1 SULFUR (Supelco Catalog 1999 Supelco Inc., BeUefonte, PA). [Pg.383]

Elemental composition Mo 36.34%, C 27.30%, 0 36.36%. A benzene solution of the hexacarbonyl may be analyzed by GC/MS. Molybdenum metal digested in nitric acid solution may be analyzed by various instrumental techniques. Also, the compound may be thermally dissociated and the liberated CO may be identified by GC using a TCD or by GC/MS using an appropriate capillary column. [Pg.590]


See other pages where Capillary column composition is mentioned: [Pg.134]    [Pg.84]    [Pg.34]    [Pg.390]    [Pg.440]    [Pg.81]    [Pg.965]    [Pg.75]    [Pg.104]    [Pg.286]    [Pg.591]    [Pg.599]    [Pg.910]    [Pg.997]    [Pg.456]    [Pg.263]    [Pg.412]    [Pg.1250]    [Pg.374]    [Pg.27]    [Pg.106]    [Pg.38]    [Pg.78]    [Pg.86]    [Pg.167]    [Pg.168]    [Pg.181]    [Pg.563]    [Pg.640]    [Pg.554]    [Pg.582]    [Pg.598]    [Pg.1250]    [Pg.260]    [Pg.34]    [Pg.314]    [Pg.317]    [Pg.567]   
See also in sourсe #XX -- [ Pg.8 ]




SEARCH



Capillary column columns)

Capillary columns

Composite column

© 2024 chempedia.info