The BioSentryTM System performed successfully and proved that it would have notified the City of an Event if Cryptosporidium had been introduced into the water supply at average LOD concentration levels above 243 organisms/ml. It further demonstrated that, with frequent calibration, the System could achieve performance levels below 100 organism/ml. [Pg.28]

Hydrogen gas monitors that are correctly calibrated on a proper schedule should be used in any power supply system to provide alarms for hazardous conditions. Automatic cut offs can be used in conjunction with an alarm system to shut down the gas flow to the power supply. [Pg.245]

It is necessary to know the heat capacity of the system to calculate the enthalpy of the reaction. This can be determined by measurement of the temperature increment produced by the reaction of a reference material, or by electrical calibration supplying a determined quantity of electrical power from a heater during a known time. There are other types of reaction calorimeters [50], such as adiabatic calorimeters, where the jacket is maintained at the same temperature as the reaction vessel during the whole experiment, and no corrections need to be applied to the observed temperature rise [51]. [Pg.551]

The adsorption column should be supplied with a number of thermocouples to observe heat effects during sorption. Also a supply system for sorptive gases and a carrier gas (He, Ar, N2) should be provided including well calibrated flow meters to set up mass balances. [Pg.344]

This simple approach was used in the plumbosolvency control programme in Wales (Hayes et al., 2008) and enabled a zonal emission model to be calibrated that good validation of predicted RDT sample results was obtained from actual RDT sample results indicated that this simple methodology was adequate for estimating the percentage of houses with a lead pipe. However, to put this into perspective, over 11,000 results were available across 29 water supply systems, with an average of 383 RDT sample results per scheme. [Pg.49]

Unsuitable fittings and pipes can reduce the quality of the pure gases and calibration gas mixtures considerably. The selection of the adequate gas supply system depends on the chemical, physical and physiological properties of the gases applied and the application-specific demands. [Pg.272]

In compliance modelling for a water supply system, the most important calibration data are (i) the lengths and diameters of the lead service lines (ii) the types (copper, brass, etc), lengths and diameters of premise plumbing (iii) the plumbosolvency of the water and (iv) the percentage of homes with a lead service line in the water supply system. The extent of this data varied in the three case studies necessitating the use of some assumptions, which were adjusted (to a limited extent) in order to match predicted compliance results to those observed. Obtaining adequate calibration data in the future on pipework characteristics should not be particularly onerous or costly, particularly if opportunities to undertake brief inspections of service connections... [Pg.12]

On the basis that the model was adequately calibrated, it was possible to predict the results of random daytime sampling for the water supply system and to predict the percentage of samples that exceeded the WHO guideline value of 10 pg/l. The percentage of failing RDT samples equates to the percentage of population at risk on this basis. [Pg.33]

This project commenced on a firm basis due to the model s extensive and successful track record from the optimisation of numerous water supply systems in the UK. The calibration data on non-lead pipe-work is not a major influence on the... [Pg.55]

An ICP-OES instrument consists of a sample introduction system, a plasma torch, a plasma power supply and impedance matcher, and an optical measurement system (Figure 1). The sample must be introduced into the plasma in a form that can be effectively vaporized and atomized (small droplets of solution, small particles of solid or vapor). The plasma torch confines the plasma to a diameter of about 18 mm. Atoms and ions produced in the plasma are excited and emit light. The intensity of light emitted at wavelengths characteristic of the particular elements of interest is measured and related to the concentration of each element via calibration curves. [Pg.634]

When solution must be pumped, consideration should be given to use of holding tanks between the dry feed system and feed pumps, and the solution water supply should be controlled to prevent excessive dilution. The dry feeders may be started and stopped by tank level probes. Variable-control metering pumps can then transfer the alum stock solution to the point of application without further dilution. Means should be provided for calibration of the chemical feeders. Volumetric feeders may be mounted on platform scales. Belt feeders should include a sample chute and box to catch samples for checking actual delivery with set delivery. Gravimetric feeders are usually furnished with totalizers only. Remote instrumentation is frequently used with gravimetric equipment, but seldom used with volumetric equipment. [Pg.95]

The Mass Spectrometer Module houses the vacuum system, capillary interface assembly, and ion-trap mass spectrometer in approximately half of the module. Also included are the reagent gas and calibration gas subassembly (a temperature-controlled housing that ensures consistent gas pressures). The other half contains the electronic printed circuit boards, power supplies, and instrument control computer. [Pg.69]

Any mass spectrometer requires mass calibration before use. However, the procedures to perform it properly and the number of calibration points needed may largely differ between different types of mass analyzers. Typically, several peaks of well-known m/z values evenly distributed over the mass range of interest are necessary. These are supplied from a well-known mass calibration compound or mass reference compound. Calibration is then performed by recording a mass spectrum of the calibration compound and subsequent correlation of experimental m/z values to the mass reference list. Usually, this conversion of the mass reference list to a calibration is accomplished by the mass spectrometer s data system. Thereby, the mass spectrum is recalibrated by interpolation of the m/z scale between the assigned calibration peaks to obtain the best match. The mass calibration obtained may then be stored in a calibration file and used for future measurements without the presence of a calibration compound. This procedure is termed external mass calibration. [Pg.99]

The column set was calibrated with a series of polystyrene stan rds with weight average molecular weights (Mw) between 2X10 and 4.1X10°. The standards were supplied by Pressure Chemical Co., Pittsburgh, Pa. and ArRo Laboratories, Inc., Joliet, 111. Other systems used in this work included the NBS-706 polystyrene standard and an emulsion polymerized polymethyl methacrylate sample. [Pg.282]


See other pages where Calibration supply systems is mentioned: [Pg.36]    [Pg.117]    [Pg.19]    [Pg.158]    [Pg.34]    [Pg.23]    [Pg.607]    [Pg.24]    [Pg.207]    [Pg.367]    [Pg.52]    [Pg.273]    [Pg.142]    [Pg.38]    [Pg.56]    [Pg.129]    [Pg.160]    [Pg.692]    [Pg.169]    [Pg.392]    [Pg.536]    [Pg.377]    [Pg.314]    [Pg.77]    [Pg.238]    [Pg.501]    [Pg.583]    [Pg.226]    [Pg.42]    [Pg.159]    [Pg.41]    [Pg.24]    [Pg.436]    [Pg.372]    [Pg.233]    [Pg.216]    [Pg.456]   