Energy calibration

Our results are the first absolute measurements of all the resonance lines in helium-like vanadium using an EBIT. We do not rely on a single calibration energy, but require a series of calibration lines to determine the dispersion function of the spectrometer. These measurements represent a 27 ppm-40 ppm determination of the helium-like resonance lines in vanadium. Results are summarized in Table 2 and the notation of Gabriel [27] for each transition is indicated. [Pg.706]

The notion of cooling time can be understood by writing (1) and assuming no calibration energy or heat loss. Then (1) becomes xC0(dT dt) = (T - Tj). If a constant temperature difference T - Tj is applied, it will take Tco time units for the reactor temperature to change by the temperature difference. [Pg.147]

Figure 8.2 presents a typical temperature plot of the calorimeter. The vertical line drawn in the middle of the graph indicates the point where the radiation loss and other energy inputs are neutralised and thus the exact temperature rise due to sample addition or due to the input of calibrating energy is obtained. [Pg.75]

Some operating parameters can be considered in common for all these detectors, notably detection efficiency and the radiation background. Additional parameters pertain only to detectors with associated spectrometers. These parameters concern the radiation energy peaks that identify and quantify radionuclides, and include energy calibration, energy resolution, peak-to-Compton ratio, and peak shape. [Pg.134]

This polymer has been the archetypal one for applications of molecular mechanics to lattice packing. It is found for well-calibrated energy function parameter sets, i.e., force fields , that the crystal structure is rqjroduced well. Table 1 shows a comparison for lattice parameters between a calculation [6] and experiment... [Pg.15]

We will use the indium and water to calibrate temperature, and indium to calibrate energy. [Pg.106]

An interpolative efficiency curve is an option within GammaVision which is intended for situations where the actual efficiency curve is known to be complicated and unlikely to conform to the other options available. In effect, the pairs of energy/efficiency data are simply stored as provided. Efficiencies at points between the calibration energies are tben estimated by interpolation between an appropriate pair of data points. In general, this is of dubious value - if the data is too... [Pg.194]

A development project has been initiated with the aim of providing a radiotracer method that ultimately can be implemented as a routine calibration method for permanently installed multiphase flowmeters. The project is supported by a research grant from the Danish Ministry of Energy. [Pg.1056]

With most non-isothemial calorimeters, it is necessary to relate the temperature rise to the quantity of energy released in the process by determining the calorimeter constant, which is the amount of energy required to increase the temperature of the calorimeter by one degree. This value can be detemiined by electrical calibration using a resistance heater or by measurements on well-defined reference materials [1], For example, in bomb calorimetry, the calorimeter constant is often detemiined from the temperature rise that occurs when a known mass of a highly pure standard sample of, for example, benzoic acid is burnt in oxygen. [Pg.1902]

Table 15. Decay Data for Radionuclides Useful for the Energy and Efficiency Calibration of 7-Ray Detectors... Table 15. Decay Data for Radionuclides Useful for the Energy and Efficiency Calibration of 7-Ray Detectors...
The assessor should also find out whether an effective testing program is in place to help ensure the serviceability of process measurement equipment. The successful toller should have an established calibration program to address the accuracy of critical measurement equipment. Safety critical process parameters should be monitored and critical process equipment should automatically interlock when monitoring instrumentation detects safety critical deviations. Interlocks should either facilitate a remedy to the critical deviation or bring the process to the zero energy state. These instruments and interlocking devices should be routinely tested to ensure operational reliability. [Pg.29]

Figure 6 Steps in automated assignment. (1) Select the lowest energy structures from iteration / — 1 that are used to interpret the spectra. (2) For each peak, list all possible assignments compatible with the resonances within a frequency mnge. (3) Extract a distance for each assignment possibility from the ensemble of structures. (4) Use the distances to assign ambiguous NOEs. (5) Calibrate the peak volumes to obtain distance restraints. (6) Calculate structures based on the new restraints. Figure 6 Steps in automated assignment. (1) Select the lowest energy structures from iteration / — 1 that are used to interpret the spectra. (2) For each peak, list all possible assignments compatible with the resonances within a frequency mnge. (3) Extract a distance for each assignment possibility from the ensemble of structures. (4) Use the distances to assign ambiguous NOEs. (5) Calibrate the peak volumes to obtain distance restraints. (6) Calculate structures based on the new restraints.

See other pages where Energy calibration is mentioned: [Pg.235]    [Pg.73]    [Pg.145]    [Pg.75]    [Pg.257]    [Pg.314]    [Pg.10]    [Pg.208]    [Pg.75]    [Pg.40]    [Pg.381]    [Pg.135]    [Pg.139]    [Pg.144]    [Pg.189]    [Pg.191]    [Pg.235]    [Pg.73]    [Pg.145]    [Pg.75]    [Pg.257]    [Pg.314]    [Pg.10]    [Pg.208]    [Pg.75]    [Pg.40]    [Pg.381]    [Pg.135]    [Pg.139]    [Pg.144]    [Pg.189]    [Pg.191]    [Pg.240]    [Pg.331]    [Pg.1120]    [Pg.1121]    [Pg.1830]    [Pg.1893]    [Pg.1905]    [Pg.1908]    [Pg.1959]    [Pg.438]    [Pg.605]    [Pg.607]    [Pg.632]    [Pg.339]    [Pg.388]    [Pg.549]    [Pg.459]    [Pg.66]    [Pg.124]    [Pg.140]   
See also in sourсe #XX -- [ Pg.49 ]

See also in sourсe #XX -- [ Pg.11 , Pg.18 ]

See also in sourсe #XX -- [ Pg.7 ]




SEARCH



Calibration full energy peak

Depth profiling energy calibration

Energy Calibration The Schmitt Method

Energy Calibration of Electron Spectrometers

Energy calibration adventitious carbon

Energy calibration work function measurement

Potential energy surfaces calibration

Software energy calibration

Velocity and Energy Calibration