Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Background extreme

A homogeneous metastable phase is always stable with respect to the fonnation of infinitesimal droplets, provided the surface tension a is positive. Between this extreme and the other thennodynamic equilibrium state, which is inhomogeneous and consists of two coexisting phases, a critical size droplet state exists, which is in unstable equilibrium. In the classical theory, one makes the capillarity approxunation the critical droplet is assumed homogeneous up to the boundary separating it from the metastable background and is assumed to be the same as the new phase in the bulk. Then the work of fonnation W R) of such a droplet of arbitrary radius R is the sum of the... [Pg.754]

A major difficulty in an inorganic text is to strike a balance between a short readable book and a longer, more detailed text which can be used for reference purposes. In reaching what we hope is a reasonable compromise between these two extremes, we acknowledge that both the historical background and industrial processes have been treated very concisely. We must also say that we have not hesitated to simplify complicated reactions or other phenomena—thus, for example, the treatment of amphoterism as a pH-dependent sequence between a simple aquo-cation and a simple hydroxo-anion neglects the presence of more complicated species but enables the phenomena to be adequately understood at this level. [Pg.458]

A modem variant is to count the number of atoms directly in a mass spectrometer.) The practical limit is about 50000 y since by this time the activity has fallen to about 0.2% of its original valuable and becomes submerged in the background counts. is also extremely valuable as a radioactive tracer for mechanistic studies using labelled compounds, and many such compounds, particularly organic ones, are commercially available (p. 310). [Pg.277]

Shipping analysis is an extremely sensitive electrochemical technique for measuring trace metals (19,20). Its remarkable sensitivity is attributed to the combination of an effective preconcentration step with advanced measurement procedures that generate an extremely favorable signal-to-background ratio. Since the metals are preconcentrated into the electrode by factors of 100 to 1000, detection limits are lowered by 2 to 3 orders of magnitude compared to solution-phase voltammetric measurements. Hence, four to six metals can be measured simultaneously in various matrices at concentration levels down to 10 10 i. utilizing relatively inexpensive... [Pg.75]

In this introductory chapter, a broad overview is given of the history of chemical warfare on earth, and the compounds, species, and mechanisms involved. The impact of human-made compounds on the environment, which is the subject of this book, is an extremely recent event in evolutionary terms. It is important to take a holistic view, and to see the effects of human-made pollutants on the environment against the background of chemical warfare in nature. [Pg.15]

It is likely that the answers to these questions will come only from more selective and sophisticated experiments than have been done hitherto, although some useful directions have been established. The use of high-sensitivity electron spin resonance for the study in situ of anticipated radical species will likely be possible, if the background signals from other radiation-produced species are not too intense. Studies of the chemistry of implanted atoms and ions in solid organometallic substrates will make it possible to start with totally unbound atoms which suffer no Auger ionization and thus to simulate the extreme of the total recoil. Careful studies of the thermal annealing effects, especially in the presence of reactive atmospheres, will... [Pg.248]

Thirdly, and most Importantly, both the krlglng algorithm and krlglng variance are Independent of data values, thus not distinguishing the estimation of extreme values (usually the most Important for pollution control) from the estimation of median or background values. [Pg.110]

An alternative to the bridge technique was recently reported for thorium analysis in silicate rocks for which both Th and Th are measured on a single lon-counting detector (Rubin 2001). With careful chemistry and mass spectrometry, °Th/ Th ratios of igneous rocks can be measured with this technique with a precision that is similar to the bridge method. The disadvantage of this technique is that °Th ion-count rates are extremely low (around 10 cps) with normal silicate thorium ratios and are therefore subject to perturbations from background variation and low-level isobaric interferences in normal samples. [Pg.36]

The Electric Power Research Institute (EPRI 1981) conducted a survey of transuranic radionuclides in the terrestrial environs of nuclear power plants in the United States in 1978-1979. The plants included two pressurized water reactors (PWRs) and two BWRs that were of modem design and had been in operation at least 3 years. The 241 Am air concentrations around all of the power plants were extremely low and indistinguishable from fallout background... [Pg.167]

The electronic coulometers allow extremely accurate determinations even of small current or voltage effects there may be some, although low, noise interference, but with today s computerization this and other background signals (e.g., residual current) can be easily eliminated. [Pg.234]

The ability to detect small genetic changes becomes more difficult as mass increases. There is further an upper mass range where analysis is impractical. For low-resolution instruments this limit is around a 100 mer. Thus the mass has to be minimized or a high-resolution instrument employed. Alternatively, the smaller the piece of DNA analyzed, the more it chemically resembles a primer or nucleotide monomer thus separation of the two during cleanup is difficult to do. If the primers and nucleotides are not removed, they can provide a massive background on MS analysis or inhibit ionization of the PCR product by preferential ionization. Thus for practical reasons it is extremely difficult to employ a PCR product below a 40 to 50mer for direct ESI MS or ESI MS-MS analysis. [Pg.31]

Sample Thickness If possible choose a sample thickness close to the optimum thickness (Sect. 7.6). Proper background correction will be difficult for extremely thin samples. It is better to shorten the exposure or even to attenuate the primary beam than to decrease the sample thickness far below the optimum thickness. [Pg.86]


See other pages where Background extreme is mentioned: [Pg.2]    [Pg.2]    [Pg.2]    [Pg.2]    [Pg.303]    [Pg.13]    [Pg.20]    [Pg.432]    [Pg.517]    [Pg.523]    [Pg.60]    [Pg.63]    [Pg.280]    [Pg.124]    [Pg.494]    [Pg.447]    [Pg.209]    [Pg.117]    [Pg.268]    [Pg.369]    [Pg.379]    [Pg.80]    [Pg.144]    [Pg.168]    [Pg.777]    [Pg.14]    [Pg.592]    [Pg.550]    [Pg.108]    [Pg.109]    [Pg.325]    [Pg.224]    [Pg.302]    [Pg.102]    [Pg.5]    [Pg.49]    [Pg.84]    [Pg.336]    [Pg.80]    [Pg.43]    [Pg.85]   


SEARCH



Extreme

Extremities

Extremizer

© 2024 chempedia.info