Auto Analyser system

In addition, as the PVC tubes contain a plasticizer and stabilizers of which producers do not give information this needs to be taken into account, particularly, when PVC additives may give problems in analytical methods. In this case, other materials may constitute a better choice. The supplier also informs the users that decaying organic material may influence N-NH4 analysis in auto-analyser systems. Another important consideration on polysulfone fibres application for soil solution sampling is the apparent retention of colloidal Fe at the fibre interface (Jones and Edwards, 1993b) which is not entirely clear and should not to be overlooked, because of the high retention of colloidal Fe and its role in the translocation of PTE in soil. [Pg.227]

A Waters Associates ALC/GPC-244 instrument with M6000A solvent delivery systems, M720 system controller, 710B WISP auto-injection system, M440 UV detector, and M730 data module was used for the HPLC analyses. The following conditions were used for reverse phase HPLC ... [Pg.194]

A Waters Associates ALC/GPC-2 4i( instrument with 6000A solvent delivery system, 660 solvent programmer, 71 OB WISP auto-injection system and a Perkin Elmer LC75 variable UV absorbance detector was used for the HPLC analyses. All analyses were run... [Pg.230]

Both, the present availability of technologies for producing miniature sensors and liquid-handling systems and the needs for portable stand-alone analysers, make it possible to develop a new class of auto-analysers, pTAS, to be applied outside a central laboratory It will be necessary to standardise the interconnection schemes for the different parts, in order to develop pTAS as modular systems, to be composed on specific application specifications... [Pg.5]

Activities of the catalysts were measured on a microreactor. About 3 g of catalyst was charged into a reactor and heat-treated in nitrogen at reaction temperature. Acetic acid was added to the process and the reaction was initiated by switching nitrogen to ethylene. Reaction product analyses were performed by an online gas chromatograph equipped with a flame ionization detector (Perkin Elmer Auto System II). [Pg.253]

SPME was carried out in 20 ml headspace vials (Shimadzu) with a CTC Combi Pal system auto injector at 70 °C for 60 min using a StableFlex fibre with an 85 pm Carboxen / PDMS coating (Sigma). Prior to analyses 0.8 pg -camphor solved in 4 pi isopropanol were added as internal standard. [Pg.163]

For the water analysis, automation is clearly best achieved with an auto-injector for the mechanical handhng of the samples coupled with on-hne data capture, using the computer to analyse the peak data. Serious consideration was given to employing the very considerable in house automation experience to construct a purpose-built auto-injector. However, in the interests of a speedy implementation of the automatic system, it was decided to purchase a commercially available auto-injector and to concentrate the laboratory s efforts on the area of on-hne data capture. Interfacing the complete system assembly via a data communications network required the development of a special control device (commhox), which allowed the LGC hardware to run unattended hut provided an audible warning in event of a fault condition. [Pg.84]

There are a wide variety of measurement systems available that will determine capacitance and loss. These include capacitance bridges (manual and auto-balance), impedance analysers, network analysers etc. It is important for the user to consider the frequency range over which the pyroelectric devices are to be used, as this will largely determine the selection of the instrument to use. As most pyroelectric detectors are used in the range 0.1 to 100 Hz, the instrument should ideally permit measurement over this frequency range. There are very few commercial capacitance and impedance analysers that will work below 20 Hz, and many low cost units... [Pg.227]

Analyses for H2O2 in laboratory-irradiated systems, in irradiated air samples including auto exhaust, and in the ambient polluted atmosphere have shown that H2O2 is present. [Pg.261]

The first fully automated instrument for chemical analysis (the Technicon Auto Analyzer ) appeared on the market in 1957. This instrument was designed to fulfill the needs of clinical laboratories, where blood and urine samples are routinely analyzed for a dozen or more chemical species. The number of such analyses demanded by modern medicine is enormous, so it is necessary to keep their cost at a reasonable level. These two considerations motivated the development of analytical. systems that perform several analyses simultaneously with a minimum input of human labor. The use of automatic instruments has spread from clinical laboratories to laboratories for the control of industrial processes and the routine determination of a wide spectrum of species in air, water, soils, and pharmaceutical and... [Pg.807]

HPLC analyses were carried out on a Waters system (Waters 501 pump. Wisp auto-sampler 710B Waters Corporation, Milford, Massachusetts, USA) equipped with a diode array detector (Waters 996). Two systems were employed. The first used a reverse phase Cl8 column (250 x 4 mm Licrosphere 100 Merck, Darmstadt, Germany) protected by a C18 (NovaPak Waters) guard column. A binary solvent system consisting of solvent A (dilute HCl, pH 2.4) and solvent B (80% acetonitrile solution acidified using concentrated HCl to pH... [Pg.130]

In order to generalize the definition of the solvent system for the case of ionic media, we shall analyse Franklin s definition. First, it should be noted that the term auto-ionization in this definition should be substituted by auto-dissociation or intrinsic acid-base equilibrium of the solvent , as a more common case of heterolytic break down of the constituent particles of a liquid. Indeed, for molecular solvents or those which are slightly ionized at room temperature, the terms autoionization and intrinsic acid-base equilibrium of the solvent , relate to the same process, whereas for ionic liquids they differ considerably. For example, although sodium nitrate (NaNOs) is subject to practically... [Pg.17]

The other overhead departments for TAP are production planning and control ( 3 million), inventory control ( 10 million), and quality control and inspection ( 7 million). Similar activity tmd cost analyses for the other overhead departments (see Tables 8-10) provide improved overhead allocations that can be used to better understand the relative profitabihty of each of the TAP auto models. The results are included in a revised profitability schedule in Table 11. It shows how a conventional costing system can lead to incorrect decisions by management. [Pg.2323]

Figure 12.13 Auto-dilution and optical particle sensor schematic of the Accusizer 770, where MC = mixing chamber, Vi, Vi, V3 = valves, P = pump, OPS = optical particle sensor, LS = laser source, D = detector, V s volts and PHA = pulse height analyser. (Courtesy of Particle Sizing Systems.)... Figure 12.13 Auto-dilution and optical particle sensor schematic of the Accusizer 770, where MC = mixing chamber, Vi, Vi, V3 = valves, P = pump, OPS = optical particle sensor, LS = laser source, D = detector, V s volts and PHA = pulse height analyser. (Courtesy of Particle Sizing Systems.)...
The use of the new system at ambient pressure and at moderate temperatures allows to follow the reaction kinetics by analysing the concentration of educts and products as a function of time. Batch experiments showed that there is a marked induction period of slow reaction progress (Fig. 18.6) [22, 60, 63]. The systems exhibit the characteristics of an auto-catalytic reaction. Addition of new monomer up to the original starting concentration during the conversion of the monomer does not result in a new induction period but shortly after completion of the reaction the system answers to another addition of monomer with a new induction period [14, 64]. In steady state experiments the polymerization was proceeding over days with constant reaction rate, i. e. without decrease of the catalyst s activity. The re-... [Pg.357]


See other pages where Auto Analyser system is mentioned: [Pg.395]    [Pg.395]    [Pg.259]    [Pg.137]    [Pg.171]    [Pg.235]    [Pg.245]    [Pg.3]    [Pg.4]    [Pg.5]    [Pg.84]    [Pg.211]    [Pg.198]    [Pg.183]    [Pg.111]    [Pg.25]    [Pg.299]    [Pg.141]    [Pg.409]    [Pg.64]    [Pg.214]    [Pg.91]    [Pg.312]    [Pg.29]    [Pg.7]    [Pg.129]   
See also in sourсe #XX -- [ Pg.395 ]