Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Audit correspondence

Procedures Do Not Correspond to the Way the Job Is Actually Done. Procedures are often developed when a system is first commissioned and are seldom revised to take into account changes in the hardware or the operating regime. In addition, procedures are often not written on the basis of a systematic analysis of the task as perceived by the workers or other personnel who have to use them. The remedy for this is to make sure that individuals who are going to use procedures are actively involved in their development. In addition, effective updating and auditing systems need to be in place to ensure that procedures are correct, and available to the persons who need them. [Pg.123]

To describe the internal quality audits in accordance with clause 4.17 of ISO 9001 and corresponding clauses of international standard ISO 9001 2000. [Pg.396]

Design a user-friendly audit report format. The audit report must ensure that observations are always accompanied by a corrective action and a corresponding time line. [Pg.447]

Common problems both on the operational and support aspects of the computer system should be part of any validation plan, e.g., backup works and incorrect data inputs can be corrected in a compliant way with corresponding audit trail entries. The predictability of the system under these tests must generate confidence in the CDS operations (trustworthiness and reliability of electronic records and electronic signatures) and the IT support. [Pg.490]

Select visibility of the audit trail in the new form that appears. There are different filter options that can be easily selected from the corresponding drop down. [Pg.745]

Amine radical-cations have been generated by the treatment of para-substituted anilines with ceric ion (Stone and Waters, 1962 Fox and Waters, 1964). When the para position is free, the initial radical-cation can react further for example, the oxidation of triphenylamine with lead tetra-acetate in the presence of boron trifluoride (Allara ei al., 1965) or with iodine (Stamires and Turkevich, 1963) gives the radical cation Ph3N+ , and, when excess of triphenylamine is used, the former oxidant leads to the radical-cation of A(, .A/, W, A -tetraphenylbenzidine. The only radical observed by the oxidation of dimethylanihne either electrochemically (Mzoguchi and Adams, 1962) or with lead tetraacetate and boron trifluoride (Allara et al., 1965) is the radical-cation of iV, .A, .A7, iV -tetramethylbenzidine. The relatively stable (hindered) anilino radical (40) has been generated from the corresponding aniline by flash photolysis audits e.s.r. spectrum has been measured in n-hexane (Land and Porter, 1961). The electronic spectrum of this radical is very similar to that of the unsubstituted anilino radical, detected during flash photolysis of aniline, but this radical is so short-lived that it has not yet been detected by e.s.r. [Pg.86]

Figure 1.6 contains an example of a standard operating procedure for the label generation and assembly of prescription items within a community pharmacy. Figure 1.7 contains an example of the corresponding audit form. Look at the questions in the audit. Which objectives are satisfied by adherence to these processes ... [Pg.8]

QA should keep records of all correspondence with the auditee and should check during the audit that the announcement letter and audit plan were received at the auditee s site. [Pg.166]

Like all documentation in clinical research, archiving is also required for QA documents, such as correspondence, audit notes, reports and certificates. [Pg.168]

This acid is formed when selenium is dissolved in nitric acid, and the solution evaporated to dryness. It is a solid which, when heated, is converted into a yellow gas, condensing again into acicular crystals. It is very soluble in water, and Iras an acid taste. In composition it corresponds to sulphurous acid. This latter acid and its salts deprive selenious acid audits salts of oxygen, causing the selenium to be deposited in the uncombined state. [Pg.104]

The arranger should obtain a comfort letter from the auditors to the issuer confirming that all financial information presented in the offering circular has been correctly extracted from the audited financial statements and that there have been no adverse changes in specified financial items since the last financial year end, in the case of balance sheet items, or when compared with the corresponding period in the last financial year, in the case of profit and loss account items. [Pg.900]

Software IV V tasks of Lungmen project are performed by GE IVVT and the OIVVT. Furthermore, the regulatory authority, the ROCAEC will perform the audits, on as-needed basis, to TPC and vendor site during the software development. The organizational structure basically corresponds to the licensing frame as shown in Figure 1. Also, the software V V activities performed at different organizational levels are briefly described as follows ... [Pg.86]

Copies of all correspondence, warnings, letters, and minutes Medical reports Site orientation procedure Attendance records Insurance certificate Safety audits and meetings Permits... [Pg.466]

An analogy can be drawn between financial audits and economic analysis. A financial audit checks that a company is conforming to the goals and standards set by external agencies such as the tax authorities and the company s own finance department. Economic analysis, which corresponds to measurement and metrics, seeks to understand issues such as the best pricing level for the company s product, labor rates, and how to finance the enterprise. [Pg.571]

Our initial round of interviews in the U.K. nuclear power industry was conducted in July 1999 with the British nuclear safety authorities— the Health and Safety Executive (HSE) Nuclear Installations Inspectorate (Nil)— and the private nuclear generating company in England (British Energy). A second round of interviews was conducted in January 2000 to follow up on open issues. Additional background information was obtained from discussions with trade union representatives and a local U.K. trade press correspondent. The U.K. interviewees were given considerable latitude to describe the process and impacts of industry restructuring in their own terms, in part because a sensitive audit was still pre-decisional at the time of the interviews. [Pg.131]

The safety problem was discussed but not submitted in the Road Safety Audit Report. It may have been submitted as a problem at a previous stage of Road Safety Audit and rejected in a corresponding Exception Report. [Pg.142]

The studies of the space-time characteristics of the Plasma Focus audits neutron emission were reported in 1965 at the Culham IAEA International Conference /4/. It was shown that the main neutron burst corresponds to the second compression of the plasma column. It was observed that in spite of some anisotropy in neutron velocity distribution there is practically no difference in the intensity of emission in radial and axial directions. On this basis the hypothesis of a moving boiler was developed, i.e., a high-tempe-rature plasma column, which emits neutrons and moves towards the cathode. [Pg.195]


See other pages where Audit correspondence is mentioned: [Pg.24]    [Pg.24]    [Pg.24]    [Pg.24]    [Pg.86]    [Pg.253]    [Pg.312]    [Pg.1051]    [Pg.1078]    [Pg.75]    [Pg.30]    [Pg.157]    [Pg.220]    [Pg.371]    [Pg.330]    [Pg.296]    [Pg.745]    [Pg.823]    [Pg.1928]    [Pg.8]    [Pg.166]    [Pg.170]    [Pg.160]    [Pg.384]    [Pg.319]    [Pg.419]    [Pg.333]    [Pg.1447]    [Pg.167]    [Pg.142]    [Pg.1310]    [Pg.312]    [Pg.390]    [Pg.393]    [Pg.129]    [Pg.70]   
See also in sourсe #XX -- [ Pg.166 ]




SEARCH



© 2024 chempedia.info