Atomic emission spectroscopy spectra

Atomic emission spectroscopy is one of the oldest instrumental techniques used for chemical analysis. It is used to study the transitions between electronic energy levels in atoms or ions. These energy differences are usually in the visible region (400-700 nm) of the electromagnetic spectrum, but if the energy difference is larger, then the transitions may lie in the ultraviolet region. [Pg.11]

Flame atomic emission spectroscopy, also called flame photometry, is based on the measurement of the emission spectrum produced when a solution containing metals or some nonmetals such as halides, sulfur, or phosphorus is introduced into a flame. In early experiments, the detector used was the analyst s eye. Those elements that emitted visible light could be identified qualitatively, and these flame tests were used to confirm the presence of certain elements in the sample, particularly alkali metals and alkaline-earth metals. A list of visible colors emitted by elements in a flame is given in Table 7.1. [Pg.450]

The chemical composition of the natural beryl sample used in this study was analyzed by X-ray wavelength dispersive spectroscopy for major atomic contents, inductivity coupled plasma-atomic emission spectroscopy for Be content, and atomic absorption sp>ectroscopy for Li and Rb contents (Table 1). The type I/II H2O contents were determined from intensities of IR bands due to the asymmetric stretching of type I and the symmetric stretching of type II in a polarized IR spectrum at RT (See the spectrum in the next section), using their molar absorption coefficients of 206 L moH cm-i and 256 L moH cm-i. [Pg.81]

ICP-AES Induct. Coupled Plasma-Atomic Emission Spectroscopy Atomize (flame, electro, thermal, ICP, etc.) Emission spectrum Conceniralion of alomic species (guanlilalive, using slandards) 3... [Pg.2088]

Atomic emission spectroscopy is one of the most useful and commonly used techniques for analyses of metals and nonmetals providing rapid, sensitive results for analytes in a wide variety of sample matrices. Elements in a sample are excited during their residence in an analytical plasma, and the light emitted from these excited atoms and ions is then collected, separated and detected to produce an emission spectrum. The instrumental components which comprise an atomic emission system include (1) an excitation source, (2) a spectrometer, (3) a detector, and (4) some form of signal and data processing. The methods discussed will include (1) sample introduction, (2) line selection, and (3) spectral interferences and correction techniques. [Pg.45]

In Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), a gaseous, solid (as fine particles), or liquid (as an aerosol) sample is directed into the center of a gaseous plasma. The sample is vaporized, atomized, and partially ionized in the plasma. Atoms and ions are excited and emit light at characteristic wavelengths in the ultraviolet or visible region of the spectrum. The emission line intensities are proportional to the concentration of each element in the sample. A grating spectrometer is used for either simultaneous or sequential multielement analysis. The concentration of each element is determined from measured intensities via calibration with standards. [Pg.48]

Knowledge on the plasma species can be obtained by the use of plasma diagnostics techniques, such as optical emission spectroscopy (OES) and mass spectroscopy (MS). Both techniques are able to probe atomic and molecular, neutral or ionized species present in plasmas. OES is based on measuring the light emission spectrum that arises from the relaxation of plasma species in excited energy states. MS, on the other hand, is generally based on the measurement of mass spectra of ground state species. [Pg.236]

The nuclear decay of radioactive atoms embedded in a host is known to lead to various chemical and physical after effects such as redox processes, bond rupture, and the formation of metastable states [46], A very successful way of investigating such after effects in solid material exploits the Mossbauer effect and has been termed Mossbauer Emission Spectroscopy (MES) or Mossbauer source experiments [47, 48]. For instance, the electron capture (EC) decay of Co to Fe, denoted Co(EC) Fe, in cobalt- or iron-containing compormds has been widely explored. In such MES experiments, the compormd tmder study is usually labeled with Co and then used as the Mossbauer source versus a single-line absorber material such as K4[Fe(CN)6]. The recorded spectrum yields information on the chemical state of the nucleogenic Fe at ca. 10 s, which is approximately the lifetime of the 14.4 keV metastable nuclear state of Fe after nuclear decay. [Pg.413]

Hi) Line Spectra Line spectra are usually encountered when the light emitting substance i.e., the radiating species are separate atomic entities (particles) which are distinctly separated from one another, as in gas. Therefore, it is invariably known as atomic spectrum . As the line spectrum depends solely upon the type of an atom, hence it enjoys the status of a predominant type of emission spectroscopy. [Pg.358]

In 1C, the election-detection mode is the one based on conductivity measurements of solutions in which the ionic load of the eluent is low, either due to the use of eluents of low specific conductivity, or due to the chemical suppression of the eluent conductivity achieved by proper devices (see further). Nevertheless, there are applications in which this kind of detection is not applicable, e.g., for species with low specific conductivity or for species (metals) that can precipitate during the classical detection with suppression. Among the techniques that can be used as an alternative to conductometric detection, spectrophotometry, amperometry, and spectroscopy (atomic absorption, AA, atomic emission, AE) or spectrometry (inductively coupled plasma-mass spectrometry, ICP-MS, and MS) are those most widely used. Hence, the wide number of techniques available, together with the improvement of stationary phase technology, makes it possible to widen the spectrum of substances analyzable by 1C and to achieve extremely low detection limits. [Pg.406]

Investigation of atomic spectra yields atomic energy levels. An important chemical application of atomic spectroscopy is in elemental analysis. Atomic absorption spectroscopy and emission spectroscopy are used for rapid, accurate quantitative analysis of most metals and some nonmetals, and have replaced the older, wet methods of analysis in many applications. One compares the intensity of a spectral line of the element being analyzed with a standard line of known intensity. In atomic absorption spectroscopy, a flame is used to vaporize the sample in emission spectroscopy, one passes a powerful electric discharge through the sample or uses a flame to produce the spectrum. Atomic spectroscopy is used clinically in the determination of Ca, Mg, K, Na, and Pb in blood samples. For details, see Robinson. [Pg.70]

During the 20-plus years that mass spectrometrists lost interest in glow discharges, optical spectroscopists were pursuing these devices both as line sources for atomic absorption spectroscopy and as direct analytical emission sources [6-10]. Traditionally, inorganic elemental analysis has been dominated by atomic spectroscopy. Since an optical spectrum is composed of lines corre-... [Pg.32]

In emission spectroscopy the molecule or atom itself serves as the somce of light with discrete frequencies to be analyzed. In some cases, such as Exp. 39, which deals with the emission spectrum of molecular iodine vapor, excitation by a monochromatic or nearly monochromatic laser or mercury lamp is utilized. For other cases, such as the emission from N2 molecules, electron excitation of nitrogen in a discharge tube provides an intense somce whose spectrum is analyzed to extract information about the electronic and vibrational levels. Such low-pressure (p < 10 Torr) line somces are available with many elements, and lamps containing Hg, Ne, Ar, Kr, and Xe are often used for calibration purposes. The Pen-Ray pencil-type lamp is especially convenient for the visible and... [Pg.619]

In 1955, A. Walsh recognized this and showed how the absorption from the great preponderance of unexcited molecules could be exploited analytically.Thus, in atomic absorption spectroscopy (AAS) the light from a (usually modulated) somce emitting the spectrum of the desired analyte element is passed through a sample atomization cell (such as a flame or graphite tube furnace), a monochromator (to isolate the desired somce emission line) and finally into a detector to allow measmement of the change in somce line... [Pg.205]


See other pages where Atomic emission spectroscopy spectra is mentioned: [Pg.214]    [Pg.292]    [Pg.317]    [Pg.353]    [Pg.419]    [Pg.1967]    [Pg.1913]    [Pg.2135]    [Pg.104]    [Pg.449]    [Pg.238]    [Pg.507]    [Pg.2945]    [Pg.61]    [Pg.69]    [Pg.1793]    [Pg.1418]    [Pg.259]    [Pg.1387]    [Pg.1415]    [Pg.2162]    [Pg.1913]    [Pg.19]    [Pg.316]    [Pg.47]    [Pg.76]    [Pg.303]    [Pg.11]    [Pg.558]    [Pg.1532]    [Pg.126]    [Pg.224]    [Pg.71]    [Pg.33]    [Pg.104]   
See also in sourсe #XX -- [ Pg.434 , Pg.435 ]