In electrochemistry, the electrode at which no transfer of electrons and ions occurs is called the polarizable electrode, and the electrode at which the transfer of electrons and/or ions takes place is called the nonpolarizable electrode as shown in Fig. 4-4. The term of polarization in electrochemistry, different from dipole polarization in physics, indicates the deviation in the electrode potential from a specific potential this specific potential is usually the potential at which no electric current flows across the electrode interface. To polarize" means to shift the electrode potential from a specific potential in the anodic (anodic polarization) or in the cathodic (cathodic polarization) direction. [Pg.89]

Fig. 10-28. Polarization curves for cell reactions of photoelectrolytic decomposition of water at a photoezcited n-type anode and at a metal cathode solid curve M = cathodic polarization curve of hydrogen evolution at metal cathode solid curve n-SC = anodic polarization curve of oxygen evolution at photoezcited n-type anode (Fermi level versus current curve) dashed curve p-SC = quasi-Fermi level of interfadal holes as a ftmction of anodic reaction current at photoezcited n-type anode (anodic polarization curve r re-sented by interfacial hole level) = electrode potential of two operating electrodes in a photoelectrolytic cell p. sc = inverse overvoltage of generation and transport ofphotoezcited holes in an n-type anode. Fig. 10-28. Polarization curves for cell reactions of photoelectrolytic decomposition of water at a photoezcited n-type anode and at a metal cathode solid curve M = cathodic polarization curve of hydrogen evolution at metal cathode solid curve n-SC = anodic polarization curve of oxygen evolution at photoezcited n-type anode (Fermi level versus current curve) dashed curve p-SC = quasi-Fermi level of interfadal holes as a ftmction of anodic reaction current at photoezcited n-type anode (anodic polarization curve r re-sented by interfacial hole level) = electrode potential of two operating electrodes in a photoelectrolytic cell p. sc = inverse overvoltage of generation and transport ofphotoezcited holes in an n-type anode.
Electrochemical corrosion protection (cathodic corrosion protection, galvanic anodes, anodic polarization). [Pg.233]

Corrosion protection of metals can take many fonns, one of which is passivation. As mentioned above, passivation is the fonnation of a thin protective film (most commonly oxide or hydrated oxide) on a metallic surface. Certain metals that are prone to passivation will fonn a thin oxide film that displaces the electrode potential of the metal by +0.5-2.0 V. The film severely hinders the difflision rate of metal ions from the electrode to tire solid-gas or solid-liquid interface, thus providing corrosion resistance. This decreased corrosion rate is best illustrated by anodic polarization curves, which are constructed by measuring the net current from an electrode into solution (the corrosion current) under an applied voltage. For passivable metals, the current will increase steadily with increasing voltage in the so-called active region until the passivating film fonns, at which point the current will rapidly decrease. This behaviour is characteristic of metals that are susceptible to passivation. [Pg.923]

Calcium carbonate (calcite) scale formation in hard water can be prevented by the addition of a small amount of soluble polyphosphate in a process known as threshold treatment. The polyphosphate sorbs to the face of the calcite nuclei and further growth is blocked. Polyphosphates can also inhibit the corrosion of metals by the sorption of the phosphate onto a thin calcite film that deposits onto the metal surface. When the polyphosphate is present, a protective anodic polarization results. [Pg.340]

Stripping voltammetry procedure has been developed for determination of thallium(I) traces in aqueous medium on a mercury film electrode with application of thallium preconcentration by coprecipitation with manganese (IV) hydroxide. More than 90% of thallium present in water sample is uptaken by a deposit depending on conditions of prepai ation of precipitant. Direct determination of thallium was carried out by stripping voltammetry in AC mode with anodic polarization of potential in 0,06 M ascorbic acid in presence of 5T0 M of mercury(II) on PU-1 polarograph. [Pg.209]

Equation (2-38) is valid for every region of the surface. In this case only weight loss corrosion is possible and not localized corrosion. Figure 2-5 shows total and partial current densities of a mixed electrode. In free corrosion 7 = 0. The free corrosion potential lies between the equilibrium potentials of the partial reactions and U Q, and corresponds in this case to the rest potential. Deviations from the rest potential are called polarization voltage or polarization. At the rest potential = ly l, which is the corrosion rate in free corrosion. With anodic polarization resulting from positive total current densities, the potential becomes more positive and the corrosion rate greater. This effect is known as anodic enhancement of corrosion. For a quantitative view, it is unfortunately often overlooked that neither the corrosion rate nor its increase corresponds to anodic total current density unless the cathodic partial current is negligibly small. Quantitative forecasts are possible only if the Jq U) curve is known. [Pg.44]

Cases I and II are examples of protection by cathodic polarization and III and IV of protection by anodic polarization. In cases I and III, the protection current can be uncontrolled, while in cases II and IV the potential has to be controlled. The development of operationally safe and widely available rectifiers (see Chapter 21)... [Pg.52]

If the technical regulations are adhered to for constructional steels in neutral waters, there are no conditions for H-induced corrosion. On the other hand, hardened and high-strength materials with hardnesses above HV 350 are very susceptible [60,82,92], since anodic polarization encourages crack formation in saline media and anodic pitting occurs with acid products of hydrolysis [93]. [Pg.66]

In Fig. 3-25 the locational dependence of t/, and is shown together. For practical applications and because of possible disturbance by foreign fields (e.g., stray currents) and t/g are less amenable to evaluation than f/g, which can always be determined by a point of inflection between two extreme values [50]. Furthermore, it should be indicated by Fig. 2-7 that there is a possibility of raising the sensitivity by anodic polarization which naturally is only applicable with small objects. In such cases care must be particularly taken that the counter electrode is sufficiently far away so that its voltage cone does not influence the reference electrodes. [Pg.125]

Anodic polarization exiting stray currents, contact with foreign cathodic... [Pg.156]

In general the population of cathodic blisters increases with cathodic polarization and the population of anodic blisters with anodic polarization. Both types of... [Pg.164]

With anodic polarization, the anodic partial reaction predominates at defects so that OH" ions formed according to Eq. (2-17) are combined in the corrosion... [Pg.166]

Anodic polarization can occur in the presence of stray currents. Oxygen is evolved on the passive steel according to ... [Pg.174]

Fig. 9-16 Interference of a short (a) and a long (b) pipeline by the anode voltage cone Hill region of cathodic polarization region of anodic polarization. Fig. 9-16 Interference of a short (a) and a long (b) pipeline by the anode voltage cone Hill region of cathodic polarization region of anodic polarization.
Then stray current enters the pipeline and the pipe/soil potential becomes more negative. The recording in Fig. 15-8b shows the behavior with a direct stray current drainage to the rails. With > 0, a current flows off the pipeline via the stray current return conductor back to the rails so that there is no anodic polarization of the pipeline. With Uf g < 0, a current flows over the connection in the pipeline and anodically polarizes it. Direct stray current drainage is therefore not possible in this case. Figure 15-8c shows the result of a rectified stray current drainage to the rails. Now the pipeline is always cathodically polarized. Cathodic protection is, however, also not fully attained. [Pg.361]

However, if the interpretation of the potentials measured for regions with a covering as uniform as possible and aeration or moisture is extended to estimate the potential gradients corresponding to the explanation for Fig. 3-24, there follows the possibility of classifying the state of corrosion [52-54]. Furthermore, the sensitivity of the estimate can be raised by anodic polarization according to the explanation given for Fig. 2-7, because the depassivated steel is less polarizable than the passive steel in concrete [43]. [Pg.433]

Since the object to be protected represents a cell consisting of active and passive steel, considerable IR errors in the cell current must be expected in measuring the off potential. The considerations in Section 3.3.1 with reference to Eqs. (3-27) and (3-28) are relevant here. Since upon switching off the protection current, 7, the nearby cathodes lead to anodic polarization of a region at risk from corrosion, the cell currents and 7, have opposite signs. It follows from Eqs. (3-27) and (3-28) that the 77 -free potential must be more negative than the off potential. Therefore, there is greater certainty of the potential criterion in Eq. (2-39). [Pg.437]

Besides the use of anodic polarization with impressed current to achieve passivation, raising the cathodic partial current density by special alloying elements and the use of oxidizing inhibitors (and/or passivators) to assist the formation of passive films can be included in the anodic protection method [1-3]. [Pg.464]

Insulating units are installed in pipelines to limit cathodic protection or to separate different materials in a mixed installation. If the pipelines are transporting electrolytes, anodic interference can occur on the pipe interior if a dc voltage, Af/, exists at the insulator of length, L. The current flowing through the insulating unit by anodic polarization of the internal wall of the pipe comes to ... [Pg.557]

Anode Polarization-the difference between the potential of an anode passing current and the steady-state or equilibrium potential of the electrode with the same electrode reaction. [Pg.46]

Oxygen dissolved in aqueous solutions, even in very low concentrations, is a leading cause of corrosion problems (i.e., pitting) in drilling. Its presence also accelerates the corrosion rate of other corrodents such as hydrogen sulfide and carbon dioxide. Oxygen plays a dual role both as a cathodic depolarizer and an anodic polarizer or passivator. Within a certain range of concentration the... [Pg.1300]

Second, oxygen attacks the metal directly by precipitating iron oxide at the anode, thus, preventing anodic polarization by Fe ions. [Pg.1301]

It is worth emphasising too, that the position of those lines representing equilibria with the dissolved species, M, depend critically on the solubility of the ion, which is a continuous function of pH. For example, iron in moderately alkaline solution is expected to be very passive and so it is in borate solutions (in the absence of aggressive ions). However, the anodic polarization curve still shows a small active loop at low potential. [Pg.135]

Anodic polarization also may occur. Typically, this begins with the formation of a thin, impervious oxide film, chemisorbed at the anode (as on the surface of stainless steels). However, for most metals used in boiler plant systems this chemisorption process must be aided by anodic corrosion inhibitors to reduce corrosion rates to tolerable levels. An example is the application of nitrite-based inhibitors, widely used in HW heating systems. [Pg.151]

Figure 8. Schematic potential distribution across a bipolar membrane under increased anodic polarization. 15 At the neutral layer, dehydration proceeds in accordance with anodic polarization. and A are the inner potential and membrane potential, respectively. (Reproduced from N. Sato, Corrosion 45,354,1989, Fig. 27 with permission from NACE International.)... Figure 8. Schematic potential distribution across a bipolar membrane under increased anodic polarization. 15 At the neutral layer, dehydration proceeds in accordance with anodic polarization. and A are the inner potential and membrane potential, respectively. (Reproduced from N. Sato, Corrosion 45,354,1989, Fig. 27 with permission from NACE International.)...

See other pages where Anode anodic polarization is mentioned: [Pg.2727]    [Pg.74]    [Pg.157]    [Pg.2429]    [Pg.2430]    [Pg.2431]    [Pg.2431]    [Pg.2431]    [Pg.2432]    [Pg.14]    [Pg.47]    [Pg.165]    [Pg.174]    [Pg.256]    [Pg.258]    [Pg.358]    [Pg.417]    [Pg.455]    [Pg.550]    [Pg.557]    [Pg.1268]    [Pg.910]    [Pg.235]    [Pg.400]    [Pg.443]    [Pg.784]    [Pg.129]    [Pg.227]   
See also in sourсe #XX -- [ Pg.33 , Pg.34 , Pg.181 , Pg.233 , Pg.234 , Pg.300 , Pg.301 , Pg.469 , Pg.528 , Pg.529 ]




SEARCH



Alloy evaluation anodic polarization curves

Alloy evaluation potentiostatic anodic polarization technique

Aluminum anodic polarization

Anode polarization

Anode polarization

Anode polarization resistance

Anodic Polarization Curve and Conditions for Electrochemical Planarization

Anodic Polarization Resulting in Passivity

Anodic Polarization Scans the Protection Potential

Anodic Polarization of Iron-Chromium-Nickel Alloys

Anodic Polarization of Several Active-Passive Alloy Systems

Anodic polarization

Anodic polarization alloys

Anodic polarization curve

Anodic polarization curves galvanic couple

Anodic polarization curves potentiostatic circuit

Anodic polarization curves sulfuric acid

Anodic polarization of aluminum

Anodic polarization of copper

Anodic polarization of iron

Anodic polarization of nickel

Anodic polarization schematic representation

Anodic polarization system

Anodic potentiodynamic polarization

Anodic reaction potential polarization

Cells with Low Anode Polarization

Chromium-nickel alloys, anodic polarization

Copper anodic polarization

Crevice corrosion anodic polarization curves

DMFC, anode polarization voltage

Electron transfer anodic polarization

Experimental Observations on the Anodic Polarization of Iron

Fuel cell performance anode polarization

Galvanostatic anode polarization

Iron-chromium alloys anodic polarization

Iron-chromium-nickel alloys anodic polarization

Lead anodic polarization

Molybdenum anodic polarization

Nickel anodic polarization

Nickel-base alloys anodic polarization

Nickel-chromium steels, anodic polarization

Passivation anodic polarization curves

Passivation stainless steel anodic polarization curve, alloying

Pitting corrosion cyclic anodic polarization scans

Polarization anode-cathode areas

Polarization curve DMFC anode

Polarization curve of anodic metal dissolution

Polarization curves anodic dissolution

Selective dissolution anodic polarization curves

Semiconductor electrodes anodic polarization

Stainless steels anodic polarization curves

Steady anodic polarizations

Steady-State Anodic Polarization

Structures Cathodically or Anodically Polarized

Sulfuric acid anodic polarization

Titanium anodic polarization

Titanium, anodic polarization curve

© 2024 chempedia.info