Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical chemistry literature

This chapter will not deal with TAE, as analytical errors are amply dealt with elsewhere in the specific chapters on the individual analytical techniques as well as in the voluminous general pertinent analytical chemistry literature. [Pg.48]

The old analytical chemistry literature is rich with methods involving homogeneous precipitation from solution, the purpose being to obtain dense (therefore easily filterable), contamination-free precipitates for purposes of analyses. The... [Pg.262]

This style of representation is limited to three variables and even then the diagrams can become confusing, particularly for a lot of points. One method for graphically representing multivariate data ascribes each variable to some characteristic of a cartoon face. These Chernoff faces have been used extensively in the social sciences and adaptations have appeared in the analytical chemistry literature. Figure 1.13 illustrates the use of Chernoff faces to represent the data from Table 1.11. The size of the forehead is proportional to tin concentration, the lower face to zinc level, mouth to nickel, and nose to iron concentration. As with the three-dimensional scatter plot, two groups can... [Pg.25]

Yes, there have been comparative studies in which the percent recovery has been measured using not only SFE but also ASE and comparing these results to percent recoveries from the more conventional Soxhlet extraction (S-LSE). Generally, these studies are done on certified reference samples or on grossly contaminated samples. We will discuss two studies from the recent analytical chemistry literature. The first study compared the efficiencies of SFE, high-pressure solvent extraction (HPSE), to S-LSE for removal of nonpesticidal organophosphates from soil (46). HPSE is very similar to accelerated solvent extraction however, we will reserve the acronym ASE for use with the commercial instrument developed by Dionex Corporation. HPSE as developed by these authors used parts available in their laboratory.. The authors compared S-LSE with SFE and HPSE for extraction of tricresyl phosphate (TCP) and triphenyl phosphate (TPP) from soil. Molecular structures for these two substances are as follows ... [Pg.152]

The analytical chemistry literature contains novel research that utilizes SPE as the principal sample preparation technique. Major journals in which it is likely that research using SPE will be presented include Analytical Chemistry and the applied biennial reviews, Journal of Chromatography, Journal of Chromatographic Science, Analytica Chimica Acta, LC-GC The Magazine of Separation Science, Environmental Testing Analysis, American Laboratory, American Environmental Laboratory, and Environmental Science and Technology. [Pg.164]

The concept of fitness for purpose is a concept that is certainly not limited to analytical chemistry and is considered here in more detail. The first formal definition of the concept in the analytical chemistry literature appears to be that of Thompson and Ramsey (Thompson 1995) in a study of sampling protocols Fitness for Purpose is the property of data produced by a measurement process that enables the user of the data to make technically correct decisions for a stated purpose. ... [Pg.461]

As has already been emphasized, no quantitative experimental result is of any value unless it is accompanied by an estimate of the errors involved in its measurement. A common practice in analytical chemistry literature is to quote the mean as the estimate... [Pg.29]

Although a complete knowledge of chemiluminescence and bioluminescence reaction mechanisms and the essential factors for the light producing steps is necessary for the optimization of these analytical methods, it is possible in most cases to use them empirically as very sensitive tools in analytical chemistry. Literature published before 1968 has been reviewed [3 a]. [Pg.167]

Problems adapted from the literature. Many of the in-chapter examples and end-of-chapter problems are based on data from the analytical literature, providing students with practical examples of current research in analytical chemistry. [Pg.814]

Finally, we note that the size and shape of the particles of the packing, the packing technique, and column dimensions and configuration are additional factors which influence a GPC experiment. In addition, the flow rate, the sample size, the sample concentration, the solvent, and the temperature must all be optimized. Details concerning these considerations are found in analytical chemistry references, as well as in the technical literature of instrument manufacturers. [Pg.652]

This short review cannot be comprehensive as of the exponential increase of the literature dealing with new procedures and applications. Table 2 summarizes selected data and lists fields of application. For a more inclusive view on the subject the interested reader is referred to existing monographs6-161 or to the critical biennial review in Analytical Chemistry. As the readers of this general volume on membranes most likely are acquainted with electro-analytical sensors, this article will be limited to the introduction of a theoretical approach which might be helpful also to researchers in the bio-membrane field. [Pg.223]

Liquid junction potential 63, 549 Literature of analytical chemistry 6, 122, 156, 251, 253, 498, 499, 640, 641, 813, 815 Lithium, D. of as aluminate, (g) 459 Litmus 265 Litre xxix, 78 Littrow mounting 661 Logarithms four figure, 843 Lovibond comparator 655 Low voltage d.c. arc 763, 771 Lubricants for glass stopcocks 85 Lyophilic colloids 419 Lyophobic colloids 419 stability of, 419... [Pg.867]

No references to the original literature are given in the text. This is because the introduction of such references would have considerably increased the size and therefore the price of the book. However, a discussion on the literature of analytical chemistry is given in the Appendix. With the aid of the various volumes mentioned therein — which should be available in all libraries of analytical chemistry — and the Collective Indexes of Chemical Abstracts or of British Chemical Abstracts, little difficulty will, in general, be experienced in finding the original sources of most of the determinations described in the book. [Pg.902]

The current literature on x-ray absorption and emission in analytical chemistry is growing rapidly. In the present book, it will unfortunately be necessary to restrict references to those adequate to support the text. The reader interested in a more complete listing of the current literature will find helpful the series of review articles given below. [Pg.41]

It is the intent of this chapter to introduce the analyst to some of the more common procedures that have been established for sample preparation. It is impossible to cover such a subject comprehensively in a single chapter and it will still be necessary for the analyst to seek support from the literature when faced with unusual samples. Fortunately, analytical LC methods have been reported in the literature for over two decades and it is highly likely that a publication exists describing a particular analysis of interest or one very similar to it. The journals that are recommended for reference are the Journal of Liquid Chromatography, the Journal of Chromatography, the Journal of Chromatographic Science, The Analyst and Analytical Chemistry. [Pg.195]

It would be of obvious interest to have a theoretically underpinned function that describes the observed frequency distribution shown in Fig. 1.9. A number of such distributions (symmetrical or skewed) are described in the statistical literature in full mathematical detail apart from the normal- and the f-distributions, none is used in analytical chemistry except under very special circumstances, e.g. the Poisson and the binomial distributions. Instrumental methods of analysis that have Powjon-distributed noise are optical and mass spectroscopy, for instance. For an introduction to parameter estimation under conditions of linked mean and variance, see Ref. 41. [Pg.29]

No ongoing studies on the analytical chemistry of mineral oils, organophosphate esters, or polyalphaolefins were located in the available literature. [Pg.330]

Probably the most extensive use of particle morphology and microscopy has been in the area of chemical microscopy. With this approach, derivatives of the analyte species are prepared, crystallized, and identified through the morphological characteristics of these derivatives [21]. Most of these applications have been superseded by modem methods of analysis, but the microscopic method can still be used by skilled practitioners for the study of trace quantities of analyte. The literature developed during the heyday of chemical microscopy is too large to be reviewed here, but advances in the field are still chronicled in the Annual Reviews issue of Analytical Chemistry [22]. A substantial review of the optical characteristics of organic compounds is available [23]. [Pg.139]

In analytical chemistry there is an ever-increasing demand for rapid, sensitive, low-cost, and selective detection methods. When POCL has been employed as a detection method in combination with separation techniques, it has been shown to meet many of these requirements. Since 1977, when the first application dealing with detection of fluorophores was published [60], numerous articles have appeared in the literature [6-8], However, significant problems are still encountered with derivatization reactions, as outlined earlier. Consequently, improvements in the efficiency of labeling reactions will ultimately lead to significant improvements in the detection of these analytes by the POCL reaction. A promising trend is to apply this sensitive chemistry in other techniques, e.g., in supercritical fluid chromatography [186] and capillary electrophoresis [56-59], An alter-... [Pg.166]

Much of the study of ECL reactions has centered on two areas electron transfer reactions between certain transition metal complexes, and radical ion-annihilation reactions between polyaromatic hydrocarbons. ECL also encompasses the electrochemical generation of conventional chemiluminescence (CL) reactions, such as the electrochemical oxidation of luminol. Cathodic luminescence from oxide-covered valve metal electrodes is also termed ECL in the literature, and has found applications in analytical chemistry. Hence this type of ECL will also be covered here. [Pg.212]


See other pages where Analytical chemistry literature is mentioned: [Pg.19]    [Pg.517]    [Pg.204]    [Pg.502]    [Pg.10]    [Pg.122]    [Pg.25]    [Pg.124]    [Pg.467]    [Pg.130]    [Pg.97]    [Pg.155]    [Pg.467]    [Pg.124]    [Pg.820]    [Pg.467]    [Pg.19]    [Pg.517]    [Pg.204]    [Pg.502]    [Pg.10]    [Pg.122]    [Pg.25]    [Pg.124]    [Pg.467]    [Pg.130]    [Pg.97]    [Pg.155]    [Pg.467]    [Pg.124]    [Pg.820]    [Pg.467]    [Pg.458]    [Pg.11]    [Pg.1]    [Pg.439]    [Pg.6]    [Pg.18]    [Pg.23]    [Pg.39]    [Pg.369]    [Pg.1]    [Pg.253]    [Pg.3]    [Pg.249]    [Pg.20]    [Pg.420]   
See also in sourсe #XX -- [ Pg.5 ]




SEARCH



Analytical chemistry analyte

Analytical chemistry analytes

Chemistry Literature

Chemistry analytical

© 2024 chempedia.info