Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analysis stationary phases

There can be no compromises concerning column bleed in GC-MS. Column bleed generally contributes to chemical noise where MS is used as the mass-dependent detector, and curtails the detection limits. The optimization of a particular S/N ratio can also be effected in GC-MS by selecting particularly thermally stable stationary phases with a low tendency to bleed. For use in trace analysis, stationary phases for high-temperature applications have proved particularly useful (Figures 2.79 and 2.80). Besides the phase itself, the film thickness also plays an important role. Thinner films and shorter columns exhibit lower column bleed. [Pg.131]

Chromatography (Section 13 22) A method for separation and analysis of mixtures based on the different rates at which different compounds are removed from a stationary phase by a moving phase... [Pg.1279]

Environmental Analysis One of the most important environmental applications of gas chromatography is for the analysis of numerous organic pollutants in air, water, and wastewater. The analysis of volatile organics in drinking water, for example, is accomplished by a purge and trap, followed by their separation on a capillary column with a nonpolar stationary phase. A flame ionization, electron capture, or... [Pg.571]

Samples and calibration standards are prepared for analysis using a 10-mL syringe. Add 10.00 mL of each sample and standard to separate 14-mL screw-cap vials containing 2.00 mL of pentane. Shake vigorously for 1 min to effect the separation. Wait 60 s for the phases to separate. Inject 3.0-pL aliquots of the pentane layer into a GC equipped with a 2-mm internal diameter, 2-m long glass column packed with a stationary phase of 10% squalane on a packing material of 80/100 mesh Chromosorb WAW. Operate the column at 67 °C and a flow rate of 25 mL/min. [Pg.576]

For most samples liquid-solid chromatography does not offer any special advantages over liquid-liquid chromatography (LLC). One exception is for the analysis of isomers, where LLC excels. Figure 12.32 shows a typical LSC separation of two amphetamines on a silica column using an 80 20 mixture of methylene chloride and methanol containing 1% NH4OH as a mobile phase. Nonpolar stationary phases, such as charcoal-based absorbents, also may be used. [Pg.590]

Capillary Electrochromatography Another approach to separating neutral species is capillary electrochromatography (CEC). In this technique the capillary tubing is packed with 1.5-3-pm silica particles coated with a bonded, nonpolar stationary phase. Neutral species separate based on their ability to partition between the stationary phase and the buffer solution (which, due to electroosmotic flow, is the mobile phase). Separations are similar to the analogous HPLC separation, but without the need for high-pressure pumps, furthermore, efficiency in CEC is better than in HPLC, with shorter analysis times. [Pg.607]

Although aimed at the introductory class, this simple experiment provides a nice demonstration of the use of GG for a qualitative analysis. Students obtain chromatograms for several possible accelerants using headspace sampling and then analyze the headspace over a sealed sample of charred wood to determine the accelerant used in burning the wood. Separations are carried out using a wide-bore capillary column with a stationary phase of methyl 50% phenyl silicone and a flame ionization detector. [Pg.610]

This somewhat lengthy experiment provides a thorough introduction to the use of GG for the analysis of trace-level environmental pollutants. Sediment samples are extracted by sonicating with 3 X 100-mL portions of 1 1 acetone hexane. The extracts are then filtered and concentrated before bringing to a final volume of 10 mL. Samples are analyzed with a capillary column using a stationary phase of 5% phenylmethyl silicone, a splitless injection, and an EGD detector. [Pg.611]

Method f2.i describes the analysis of the trihalomethanes CHCI3, CHBr3, CHChBr, and CHClBr2 in drinking water using a packed column with a nonpolar stationary phase. Predict the order in which these four trihalomethanes will elute. [Pg.616]

Gas chromatography (gc) is inferior to hplc in separating abiUty. With gc, it is better to use capillary columns and the appHcation is then limited to analysis (67). Resolution by thin layer chromatography or dc is similar to Ic, and chiral stationary phases developed for Ic can be used. However, tic has not been studied as extensively as Ic and gc. Chiral plates for analysis and preparation of micro quantities have been developed (68). [Pg.279]

In the analytical chromatographic process, mixtures are separated either as individual components or as classes of similar materials. The mixture to be separated is first placed in solution, then transferred to the mobile phase to move through the chromatographic system. In some cases, irreversible interaction with the column leaves material permanently attached to the stationary phase. This process has two effects because the material is permanently attached to the stationary phase, it is never detected as leaving the column and the analysis of the mixture is incomplete additionally, the adsorption of material on the stationary phase alters the abiHty of that phase to be used in future experiments. Thus it is extremely important to determine the ultimate fate of known materials when used in a chromatographic system and to develop a feeling for the kinds of materials in an unknown mixture before use of a chromatograph. [Pg.105]

Chiral Chromatography. Chiral chromatography is used for the analysis of enantiomers, most useful for separations of pharmaceuticals and biochemical compounds (see Biopolymers, analytical techniques). There are several types of chiral stationary phases those that use attractive interactions, metal ligands, inclusion complexes, and protein complexes. The separation of optical isomers has important ramifications, especially in biochemistry and pharmaceutical chemistry, where one form of a compound may be bioactive and the other inactive, inhibitory, or toxic. [Pg.110]

Mass-action model of surfactant micelle formation was used for development of the conceptual retention model in micellar liquid chromatography. The retention model is based upon the analysis of changing of the sorbat microenvironment in going from mobile phase (micellar surfactant solution, containing organic solvent-modifier) to stationary phase (the surfactant covered surface of the alkyl bonded silica gel) according to equation ... [Pg.81]

For carrying out of given researches method of synthetic pyrethroids determination in air has been developed. Chromatographic behaviour is investigated and optimum conditions of the synthetic pyrethroids analysis with application of capillary column with stationary phase DB-5 and electron-capture detector are selected. [Pg.217]

Methods of analysis of volatile organie eompounds admixtures in vaiious objeets, as a mle, require sepai ation and eoneentration followed by the gas ehromatographie analysis of eoneentrate. Besides, for volatile amino-eompounds determination a limited number of stationary phases is suitable. Neeessary equipment and reagents are not always present in ordinary analytieal laboratories, and implementation of the analysis needs a highly skilled staff. [Pg.331]

This type of chromatographic development will only be briefly described as it is rarely used and probably is of academic interest only. This method of development can only be effectively employed in a column distribution system. The sample is fed continuously onto the column, usually as a dilute solution in the mobile phase. This is in contrast to displacement development and elution development, where discrete samples are placed on the system and the separation is subsequently processed. Frontal analysis only separates part of the first compound in a relatively pure state, each subsequent component being mixed with those previously eluted. Consider a three component mixture, containing solutes (A), (B) and (C) as a dilute solution in the mobile phase that is fed continuously onto a column. The first component to elute, (A), will be that solute held least strongly in the stationary phase. Then the... [Pg.8]

An interesting and practical example of the use of thermodynamic analysis is to explain and predict certain features that arise in the application of chromatography to chiral separations. The separation of enantiomers is achieved by making one or both phases chirally active so that different enantiomers will interact slightly differently with the one or both phases. In practice, it is usual to make the stationary phase comprise one specific isomer so that it offers specific selectivity to one enantiomer of the chiral solute pair. The basis of the selectivity is thought to be spatial, in that one enantiomer can approach the stationary phase closer than the other. If there is no chiral selectivity in the stationary phase, both enantiomers (being chemically identical) will coelute and will provide identical log(Vr ) against 1/T curve. If, however, one... [Pg.80]


See other pages where Analysis stationary phases is mentioned: [Pg.242]    [Pg.1267]    [Pg.2]    [Pg.4]    [Pg.242]    [Pg.1267]    [Pg.2]    [Pg.4]    [Pg.377]    [Pg.1287]    [Pg.215]    [Pg.580]    [Pg.589]    [Pg.610]    [Pg.770]    [Pg.54]    [Pg.62]    [Pg.69]    [Pg.443]    [Pg.49]    [Pg.242]    [Pg.100]    [Pg.105]    [Pg.109]    [Pg.15]    [Pg.391]    [Pg.1530]    [Pg.1531]    [Pg.1531]    [Pg.98]    [Pg.384]    [Pg.393]    [Pg.17]    [Pg.309]    [Pg.12]    [Pg.17]    [Pg.231]   
See also in sourсe #XX -- [ Pg.536 ]

See also in sourсe #XX -- [ Pg.390 ]




SEARCH



Phase analysis

© 2024 chempedia.info