Analysis methods immunoassay

Two general approaches have been used to overcome matrix effects (1) partial purification of the analyte prior to analysis by immunoassay ( cleanup methods) and (2) the use of a matrix blank when preparing the calibration curve. Both options are widely used, but each has its individual limitations. [Pg.684]

Most of the reported methods of analysis of valproic acid and its sodium salt in biological fluids rely on the use of chromatography, especially gas chromatography, although high performance liquid chromatography (HPLC) is also reported. Other methods, such as flow injection analysis, enzyme-immunoassay, fluorescence-polarization capillary electrophoresis, and potentiometry are sometimes used. The reported methods can be classified as follows. [Pg.228]

Methods based on gravimetric analysis (Table 7.2) are also simple and rapid, but they suffer from the same limitations as those of infrared spectrometric methods (Table 7.2). Gravimetric-based methods may be useful for oily sludge and wastewaters, which will present analytical difficulties for other, more sensitive methods. Immunoassay methods for the measurement of total petroleum hydrocarbon are also popular for field testing because they offer a simple, quick technique for in situ quantification of the total petroleum hydrocarbons. [Pg.191]

As a process analytical solution, these extrinsic reactive approaches necessitate an extrinsic optode (see later discussion), an on-line sample conditioning system or an at-Une solution such as a flow injection analysis (FIA) system or other autonomous solutions. Reaction kinetics, post analysis cleanup such as rejuvenating a substrate (optode, immobilized based immunoassays, etc.) among other complexities are additional considerations for these types real-time analysis methods. ... [Pg.340]

Generally, after isolation and before analysis, cocaine analytes and opioids are extracted with either liquid-liquid extraction (LLE) or solid-phase extraction (SPE) methods. Immunoassay detection techniques, however, often use the crude isolation solution. Baumgartner et al. noted that while isolating and extracting is the best... [Pg.158]

Modification of the prcformulation format for biotechnological products from the original guidance must be considered. The sections regarding chemical structure, physicochemical properties, and stability may be revised according to the nature and characteristics of proteins and peptides. Aside from the conventional analytical instruments and techniques used in the study of small molecules, methods such as amino acid analysis, sequence analysis bioassay, immunoassay, and enzymatic assay are commonly used and should be included in the report. [Pg.184]

The chemical and biosensor market is currently at a stage very similar to immunoassay in the 1970s. Traditional analysis methods, as well as immunoassay, are being challenged by new sensors. The number of sensor products is currently limited, however, and the players are mainly small companies with limited product lines. As yet, there is no single company or group of companies who could be considered dominant in chemical or biosensors. [Pg.573]

Analysis Methods for Liquid Impinger Solutions or Air Filter Samples Immunoassay Methods for Microbial Surface Antigens... [Pg.87]

Sample preparation. Although there is not a gold standard for sample preparation and target extraction for analysis by immunoassay, most use saline buffers (e.g., phosphate-buffered saline, Tris saline buffer, high-salt buffers) at neutral pH to prevent interference and inhibition of antigen-antibody binding. Similarly, there is no standardized extraction method for DNA-based assays, and extraction efficiency is matrix dependent. However, unlike immunoassays, DNA-based assays will withstand the use of harsh conditions. [Pg.242]

In many instrumental analysis methods the instrument response is proportional to the analyte concentration over substantial concentration ranges. The simplified calculations that result encourage analysts to take significant experimental precautions to achieve such linearity. Examples of such precautions include the control of the emission line width of a hollow-cathode lamp in atomic absorption spectrometry, and the size and positioning of the sample cell to minimize inner filter artefacts in molecular fluorescence spectrometry. However, many analytical methods (e.g. immunoassays and similar competitive binding assays) produce calibration plots that are intrinsically curved. Particularly common is the situation where the calibration plot is linear (or approximately so) at low analyte concentrations, but becomes curved at higher analyte levels. When curved calibration plots are obtained we still need answers to the questions listed in Section 5.2, but those questions will pose rather more formidable statistical problems than occur in linear calibration experiments. [Pg.138]

Since many laboratories are not equipped for radiochemical analysis, an immunoassay method utilizing anti-limonin antibodies produced in rabbits and... [Pg.68]

P. A. Cunniff, ed.. Official Methods of Analysis of AO AC International, 16th ed., Vols. I and II, AO AC International, Arlington, Va., 1995. Vol. I includes Pesticide Formulations and Pesticide Residues. Over 2100 coUabotatively tested, approved methods for chemical and microbiological analyses, with 149 new methods, 103 revised/updated methods, methods using anibody-based test kits, enzyme immunoassay, and annual supplements containing new and revised methods chemical and common names of all dmgs and pesticides easy-to-locate references. [Pg.153]

A number of soHd-phase automated immunoassay analyzers have been used for performing immunoassays. Table 5 (96) provides usefiil information on maximum tests that can be mn per hour, as well as the maximum number of analytes per sample. A number of immunoassay methods have been found usefiil for environmental analysis (see AUTOMATED INSTRUMENTATION). [Pg.247]

Biopolymers are employed in many immunological techniques, including the analysis of food, clinical samples, pesticides, and in other areas of analytical chemistry. Immunoassays (qv) are specific, sensitive, relatively easy to perform, and usually inexpensive. For repetitive analyses, immunoassays compare very favorably with many conventional methods in terms of both sensitivity and limits of detection. [Pg.100]

An enzyme immunoassay technique has been employed for measuring endosulfan and its degradation products (i.e., endosulfan diol, endosulfan sulfate, endosulfan ether, and endosulfan lactone) in water at 3 ppb (Chau and Terry 1972 Musial et al. 1976). However, this technique is not currently in use in environmental residue analysis. Further research into this technique could produce a rapid, rehable, and sensitive method for identifying contaminated areas posing a risk to human health. No additional methods for detecting endosulfan in environmental media appear to be necessary at this time. However, methods for the determination of endosulfan degradation products are needed. [Pg.261]

The use of immunoassay methodology for residue trial analysis is in principle just as acceptable as for enforcement methods, provided that the method has been adequately validated. Because the validation of such methods requires a different approach, as opposed to chromatographic and spectrometric methods, some important points to be aware of in the use are explained in SANCO/3029/99. The authors do not go into detail on this subject here, since on the one hand very few methods have been submitted up to the present, and on the other it would go beyond the scope of this article. [Pg.34]


See other pages where Analysis methods immunoassay is mentioned: [Pg.724]    [Pg.67]    [Pg.138]    [Pg.8]    [Pg.184]    [Pg.151]    [Pg.67]    [Pg.95]    [Pg.167]    [Pg.325]    [Pg.596]    [Pg.228]    [Pg.2]    [Pg.605]    [Pg.1038]    [Pg.453]    [Pg.327]    [Pg.1562]    [Pg.2103]    [Pg.4901]    [Pg.5089]    [Pg.304]    [Pg.220]    [Pg.941]    [Pg.49]    [Pg.21]    [Pg.451]    [Pg.244]    [Pg.101]    [Pg.254]    [Pg.241]    [Pg.112]    [Pg.8]    [Pg.311]   