Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analysis hydrides

Lab method using continuous flow or flow injection analysis hydride generation and atomic absorption spectrometry... [Pg.360]

The use of pH variation and isotope effects in transient kinetics can be illustrated with a recent study on dihydrofolate reductase. Analysis by steady-state methods had indicated an apparent p/fa of 8.5 that was assigned to an active site aspartate residue required to stabilize the protonated state of the substrate (59). In addition, it was shown that there was an isotope effect on substitution of NADPD (the deuterated analog) for NADPH at high pH but not at low pH, below the apparent p/fa This somewhat puzzling finding was explained by transient-state kinetic analysis. Hydride transfer, the chemical reaction converting enzyme-bound NADPH and dihydrofolate to NAD+ and tetrahydrofolate, was shown to occur at a rate of approximately 1000 sec at low pH. The rate of reaction decreased with increasing pH with a of 6.5, a value more in line with expectations for an active site aspartate residue. As shown in Fig. 14, there was a threefold reduction in the rate of the chemical reaction with NADPD relative to NADPH. Thus direct measurement of the chemical reaction revealed the full isotope effect. [Pg.54]

G. E. Pacey, M. R. Straka, and J. R. Gord, Dual Phase Gas Diffusion Flow Injection Analysis/Hydride Generation Atomic Absorption Spectrometry. Anal. Ghent., 58 (1986) 502. [Pg.450]

Other techniques used in this context include graphite furnace analysis, hydride generation, and cold-vapor absorption. Other applications involve the indirect FIA-AAS determination of some drugs in pharmaceutical formulations based on a prior reaction or precipitation, or redox or complex formation. Examples are shown in Table 6. [Pg.1311]

Fundamentally, introduction of a gaseous sample is the easiest option for ICP/MS because all of the sample can be passed efficiently along the inlet tube and into the center of the flame. Unfortunately, gases are mainly confined to low-molecular-mass compounds, and many of the samples that need to be examined cannot be vaporized easily. Nevertheless, there are some key analyses that are carried out in this fashion the major one i.s the generation of volatile hydrides. Other methods for volatiles are discussed below. An important method of analysis uses lasers to vaporize nonvolatile samples such as bone or ceramics. With a laser, ablated (vaporized) sample material is swept into the plasma flame before it can condense out again. Similarly, electrically heated filaments or ovens are also used to volatilize solids, the vapor of which is then swept by argon makeup gas into the plasma torch. However, for convenience, the methods of introducing solid samples are discussed fully in Part C (Chapter 17). [Pg.98]

A number of elements form volatile hydrides, as shown in the table. Some elements form very unstable hydrides, and these have too transient an existence to exist long enough for analysis. Many elements do not form stable hydrides or do not form them at all. Some elements, such as sodium or calcium, form stable but very nonvolatile solid hydrides. The volatile hydrides listed in the table are gaseous and sufficiently stable to allow analysis, particularly as the hydrides are swept into the plasma flame within a few seconds of being produced. In the flame, the hydrides are decomposed into ions of their constituent elements. [Pg.99]

The elements listed in the table of Figure 15.2 are of importance as environmental contaminants, and their analysis in soils, water, seawater, foodstuffs and for forensic purposes is performed routinely. For these reasons, methods have been sought to analyze samples of these elements quickly and easily without significant prepreparation. One way to unlock these elements from their compounds or salts, in which form they are usually found, is to reduce them to their volatile hydrides through the use of acid and sodium tetrahydroborate (sodium borohydride), as shown in Equation 15.1 for sodium arsenite. [Pg.99]

A major advantage of this hydride approach lies in the separation of the remaining elements of the analyte solution from the element to be determined. Because the volatile hydrides are swept out of the analyte solution, the latter can be simply diverted to waste and not sent through the plasma flame Itself. Consequently potential interference from. sample-preparation constituents and by-products is reduced to very low levels. For example, a major interference for arsenic analysis arises from ions ArCE having m/z 75,77, which have the same integral m/z value as that of As+ ions themselves. Thus, any chlorides in the analyte solution (for example, from sea water) could produce serious interference in the accurate analysis of arsenic. The option of diverting the used analyte solution away from the plasma flame facilitates accurate, sensitive analysis of isotope concentrations. Inlet systems for generation of volatile hydrides can operate continuously or batchwise. [Pg.99]

Gases and vapors of volatile liquids can be introduced directly into a plasma flame for elemental analysis or for isotope ratio measurements. Some elements can be examined by first converting them chemically into volatile forms, as with the formation of hydrides of arsenic and tellurium. It is important that not too much analyte pass into the flame, as the extra material introduced into the plasma can cause it to become unstable or even to go out altogether, thereby compromising accuracy or continuity of measurement. [Pg.102]

A. P. ScanziUo, Emyclopedia Industrial Chemicaldnalysis, Vol. 2, John Wiley Sons, Inc., New York, 1971 pp. 242—260. Analysis of hydrides. [Pg.307]

Numerous methods have been pubUshed for the determination of trace amounts of tellurium (33—42). Instmmental analytical methods (qv) used to determine trace amounts of tellurium include atomic absorption spectrometry, flame, graphite furnace, and hydride generation inductively coupled argon plasma optical emission spectrometry inductively coupled plasma mass spectrometry neutron activation analysis and spectrophotometry (see Mass spectrometry Spectroscopy, optical). Other instmmental methods include polarography, potentiometry, emission spectroscopy, x-ray diffraction, and x-ray fluorescence. [Pg.388]

Few-monolayer thin-film analysis, e.g., adsorbate and very thin-film reactions submicron detection of metal hydrides... [Pg.25]

The key features of Curran s productive and elegant tandem radical cyclization strategy are illustrated in a retrosynthetic analysis for hirsutene (1) (see Scheme 27). The final synthetic event was projected to be an intermolecular transfer of a hydrogen atom from tri-rc-butyltin hydride to the transitory tricyclic vinyl radical 131. The latter can then be traced to bicyclic tertiary radical 132 and thence to monocyclic primary radical 133 through successive hex-5-enyl-like radical cyclizations. It was anticipated that the initial radical 133 could be generated through the abstraction of the iodine atom from... [Pg.409]

We now tum our attention to the C21-C28 fragment 158. Our retrosynthetic analysis of 158 (see Scheme 42) identifies an expedient synthetic pathway that features the union of two chiral pool derived building blocks (161+162) through an Evans asymmetric aldol reaction. Aldehyde 162, the projected electrophile for the aldol reaction, can be crafted in enantiomerically pure form from commercially available 1,3,4,6-di-O-benzylidene-D-mannitol (183) (see Scheme 45). As anticipated, the two free hydroxyls in the latter substance are methylated smoothly upon exposure to several equivalents each of sodium hydride and methyl iodide. Tetraol 184 can then be revealed after hydrogenolysis of both benzylidene acetals. With four free hydroxyl groups, compound 184 could conceivably present differentiation problems nevertheless, it is possible to selectively protect the two primary hydroxyl groups in 184 in... [Pg.611]

The relative probabilities of Reactions 24, 25, and 26 were, respectively, 1.00, 0.25, and 0.12 at a hydrogen pressure of about 1 atmosphere (9). These numbers could be derived either by analyzing the stable alkanes formed in the unimolecular decompositions (Reactions 24-26) or from the products of the hydride transfer reactions between C5Hi2 and the alkyl ions. Elimination of H2 from protonated pentane may also occur, but it is difficult (although not impossible) to establish this reaction through neutral product analysis. [Pg.280]


See other pages where Analysis hydrides is mentioned: [Pg.344]    [Pg.337]    [Pg.420]    [Pg.1473]    [Pg.344]    [Pg.337]    [Pg.420]    [Pg.1473]    [Pg.208]    [Pg.99]    [Pg.503]    [Pg.503]    [Pg.335]    [Pg.48]    [Pg.49]    [Pg.41]    [Pg.4]    [Pg.189]    [Pg.71]    [Pg.281]    [Pg.498]    [Pg.500]    [Pg.70]    [Pg.302]    [Pg.762]    [Pg.140]    [Pg.140]    [Pg.1270]    [Pg.17]    [Pg.474]    [Pg.580]    [Pg.227]    [Pg.442]    [Pg.151]    [Pg.1070]    [Pg.137]    [Pg.272]    [Pg.213]   
See also in sourсe #XX -- [ Pg.27 , Pg.30 , Pg.200 ]




SEARCH



Arsenic analysis using hydride generation-atomic

Complex hydrides analysis

Flow injection analysis with hydride generation

Gaseous hydride analysis

Hydride compositional analysis techniques

Hydride generation, trace metal analysis

Lithium aluminium hydride analysis using

Metal analysis hydride generation methods

© 2024 chempedia.info