Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analysis and Output

Two important considerations in probabilistic exposure assessment are whether to quantify uncertainty and whether to separate it from variability within the analysis and output ... [Pg.12]

A Biopipe protocol represents a series of analyses. Each unit of analysis consists of specifications for input, analysis, and output. The input layer consists of a number of adaptors for various common database formats or for remote fetching from Web sources like GenBank. The role of the input layer is to retrieve data into a common format for a subsequent analysis. The complementary output layer contains adaptors to push the analysis result out to the desired database or format. The analysis layer functions through the action of wrapper Biopipe Perl modules that make standard Bioperl runnable binaries accessible to the Biopipe system. An explicit design goal of Biopipe is to reuse the encapsulations of binary tools, importers, and exporters that Bioperl already includes, with thin wrappers that specify the inputs that the input layer must provide in a workflow context. [Pg.443]

Figure 19.1 is a block diagram of a typical process analyzer system, consisting of a sample collection and conditioning system, sample manifold, sample inlet, ion source, mass analyzer, detector, and a data analysis and output system that interfaces with the process control system. The dashed line indicates the parts of the overall system that are considered to comprise the analyzer itself (i.e., what is normally included when one purchases a process MS). Figure 19.2 is a photograph of a commercial process MS that incorporates these components. Aspects of these various components are described below, with emphasis on how they are applied in a process mass spectrometer. [Pg.913]

An additional feature of ELECTRAS is a module which provides an introduction to various data analysis techniques One part of this module provides a typical work flow for data analysis. It explains the important steps when conducting a data analysis and describes the output of the data analysis methods. The second part gives a description of the methods offered. This modvJe can be used both as a guideline for novice users and as a reference for experts. [Pg.452]

Any program developed in-house must be easy to use, or user-friendly. If the program has various options for input, analysis, computation, and output, then it must provide the user with a fast way to select them. To meet this need, the system is likely to be menu-driven. The peripheral interactive devices such as mice, joysticks, light pens, graphic tablets, and templates are helpful and often used to expedite the selection process. [Pg.65]

BPCS/SIS functions that produce a trend analysis of input and output functions. Graphic video displays set-up to indicate process conditions and valve positions assure that the status of the process conditions is announced to the board operator, who may then verify the conditions with the field operator. [Pg.82]

This directory contains the USEPA Pesticide and Industrial Chemical Risk Analysis and Hazard Assessment system. Documentation for PIRANHA is contained in a MANUALS subdirectory enter PIRANHA C where C is a hard disk to receive the output files to run the sy stem. For efficient operation of PIRANHA, transfer the files from the CD-ROM to your hard disk, (it requires 28 MB). Data files are accessed from the CD-ROM when running PIRANHA. [Pg.371]

Life cycle assessment (LCA) An analysis defined by ISO 14040 as compilation and evaluation of inputs and outputs and the potential environmental impacts of a production system throughout its life cycle. ... [Pg.1455]

The (arbitrary) overall efficiency and specific work quantities obtained from these calculations are illustrated as carpet plots in Fig. 4.11. It is seen that the specific work is reduced by the turbine cooling, which leads to a drop in the rotor inlet temperature and the turbine work output. Again this conclusion is consistent with the preliminary analysis and calculations made earlier in this chapter. [Pg.66]

Opens specified file and redirects PRINT and OUTPUT text to the file for post-mortem analysis. ENDFILE or SAVE will close the file. [Pg.681]

The character and the degree of automation in chemical control may have been covered in the above treatment of semi-automatic or completely automatic, and of discontinuous or continuous analysis, but something more should be said about the means by which automation proper has been performed in recent times. Whereas in the past automated analysis involved the use of merely, mechanical robots, to-day s automation is preferably based on computerization in a way which can best be explained with a few specific examples. Adjustment knobs have been increasingly replaced with push-buttons that activate an enclosed fully dedicated microcomputer or microprocessor in line with the measuring instrument the term microcomputer is applicable if, apart from the microprocessor as the central processing unit (CPU), it contains additional, albeit limited, memory (e.g., 4K), control logics and input and output lines, by means of which it can act as satellite of a larger computer system (e.g., in laboratory computerization) if not enclosed, the microcomputer is called on-line. [Pg.327]

In this chapter, we focus on recent and emerging technologies that either are or soon will be applied commercially. Older technologies are discussed to provide historic perspective. Brief discussions of potential future technologies are provided to indicate current development directions. The chapter substantially extends an earlier publication (Davis et al., 1996a) and is divided into seven main sections beyond the introduction Data Analysis, Input Analysis, Input-Output Analysis, Data Interpretation, Symbolic-Symbolic Interpretation, Managing Scale and Scope of Large-Scale Process Operations, and Comprehensive Examples. [Pg.9]

Sometimes more meaningful features may be obtained by considering the behavior of both input and output variables together in the analysis. [Pg.10]

Both inputs and outputs, as in input-output analysis and interpretation methods... [Pg.12]

Among these, the most widely used is the radial basis function network (RBFN). The key distinctions among these methods are summarized in Table I and discussed in detail in Bakshi and Utojo (1998). An RBFN is an example of a method that can be used for both input analysis and input-output analysis. As discussed earlier, the basis functions in RBFNs are of the form 0( xj - tm 2), where tm denotes the center of the basis function. One of the most popular basis functions is the Gaussian,... [Pg.40]

The most serious problem with input analysis methods such as PCA that are designed for dimension reduction is the fact that they focus only on pattern representation rather than on discrimination. Good generalization from a pattern recognition standpoint requires the ability to identify characteristics that both define and discriminate between pattern classes. Methods that do one or the other are insufficient. Consequently, methods such as PLS that simultaneously attempt to reduce the input and output dimensionality while finding the best input-output model may perform better than methods such as PCA that ignore the input-output relationship, or OLS that does not emphasize input dimensionality reduction. [Pg.52]


See other pages where Analysis and Output is mentioned: [Pg.346]    [Pg.191]    [Pg.84]    [Pg.98]    [Pg.95]    [Pg.921]    [Pg.584]    [Pg.346]    [Pg.191]    [Pg.84]    [Pg.98]    [Pg.95]    [Pg.921]    [Pg.584]    [Pg.1284]    [Pg.1423]    [Pg.274]    [Pg.2555]    [Pg.338]    [Pg.43]    [Pg.25]    [Pg.153]    [Pg.174]    [Pg.360]    [Pg.62]    [Pg.571]    [Pg.10]    [Pg.42]    [Pg.67]    [Pg.216]    [Pg.249]    [Pg.253]    [Pg.27]    [Pg.45]    [Pg.79]    [Pg.218]    [Pg.670]    [Pg.5]    [Pg.8]    [Pg.10]    [Pg.179]   


SEARCH



Analysis, Display and Output Tools in ID WIN-NMR

Output Analysis

© 2024 chempedia.info