Air conditioning controls

FIGURE 9.13 MID solar sensor for in-car air-conditioning control (graphics courtesy of HARTING Mitronics/HELLA Fahrzeugkomponenten)... [Pg.294]

Fuel passing through certain hot zones of an aircraft can attain high temperatures moreover it is used to cool lubricants, hydraulic fluids, or air conditioning. It is therefore necessary to control the thermal stability of jet fuels, more particularly during supersonic flight where friction heat increases temperatures in the fuel tanks. [Pg.229]

B. C. Langley, Control Systemsfor Air Conditioning and Refrigeration, Prentice Had, Englewood Cliffs, N.J. 1985. [Pg.365]

R. W. Haines, Control Systems for Heating Ventilating and Air Conditioning, Van Nostrand-Reinhold, New York, 4th ed., 1987. [Pg.365]

Although the temperature can be controlled with a weU-designed air-conditioning system, the small fluctuations which most cycling systems cause may be very harmful. The temperature—time record should be a continuous, flat graph. [Pg.428]

Polyethylene. This is essentially a closed-ceU insulation manufactured at 448 2 K by an extmsion process. A blowing agent and nucleating agent are employed to control the ceU size, and primary use is in insulating pipelines for hot and chilled water lines, air conditioning, and processing systems. [Pg.332]

In air conditioning (qv) of closed spaces, a wider latitude in design features can be exercised (23,24). Blowers are used to pass room or cabin air through arrays of granules or plates. Efficiencies usuaHy are 95% or better. The primary limiting factor is the decreased rate of absorption of carbon dioxide. However, an auxHiary smaH CO2 sorption canister can be used. Control of moisture entering the KO2 canister extends the life of the chemical and helps maintain the RQ at 0.82. [Pg.487]

A central location where instmment leads are short is preferred. In modem faciHties with distributed control systems, all units are controUed from a central control room with few operators. Only a few roving operators are available to spot trouble. It is desirable to deep process equipment a minimum of 8 m away from the control room. Any equipment and hydrocarbon-containing equipment should be separated by at least 15 m if possible. Most control rooms are designed with blastproof constmction and have emergency backup power and air conditioning. The room is pressuri2ed to prevent infusion of outside air that may have hydrocarbon content in the explosive range. [Pg.79]

The performance of the catalytic converter is affected by the conditions of air/fuel control provided by the fuel metering system. A slowly responding fuel metering system can dramatically decrease the conversion efficiency of the converter compared to a fast response multipoint fuel injection system. [Pg.491]

Air-Flow Control Process operating reqmrements and weather conditions are considered in determining the method of controlling air flow. The most common methods include simple on-off control, on-off step control (in the case of multiple-driver units), two-speed-motor control, variable-speed drivers, controllable fan pitch, manually or automatically adjustable louvers, and air recirculation. [Pg.1080]

Operating co.sts. Power requirements for air-cooled heat exchangers can be lower than at the summer design condition provided that an adequate means of air-flow control is used. The annual power requirement for an exchanger is a function of the means of airflow control, the exchanger seiwice, the air-temperature rise, and the approach temperature. [Pg.1082]

In industrial air-conditioning systems, harmful environmental gases, vapors, dusts, and fumes are often encountered. These contaminants can be controlled by exhaust systems at the source, by dilution ventilation, or by a combination of the two methods. When exhaust... [Pg.1104]

Scroll compressors are currently used in relatively smaU-sized installations, predominantly for residential air-conditioning (up to 50 kW). They are recognized for low-noise operation. Two scrolls (free-standing, involute spirals bounded on one side by a flat plate) facing each other form a closed volume while one moves in a controlled orbit around a fixed point on the other, fixed scroll. [Pg.1112]


See other pages where Air conditioning controls is mentioned: [Pg.362]    [Pg.516]    [Pg.420]    [Pg.60]    [Pg.362]    [Pg.362]    [Pg.589]    [Pg.526]    [Pg.294]    [Pg.362]    [Pg.516]    [Pg.420]    [Pg.60]    [Pg.362]    [Pg.362]    [Pg.589]    [Pg.526]    [Pg.294]    [Pg.612]    [Pg.278]    [Pg.266]    [Pg.352]    [Pg.360]    [Pg.361]    [Pg.361]    [Pg.363]    [Pg.363]    [Pg.363]    [Pg.363]    [Pg.363]    [Pg.363]    [Pg.402]    [Pg.354]    [Pg.442]    [Pg.443]    [Pg.477]    [Pg.145]    [Pg.115]    [Pg.402]    [Pg.195]    [Pg.872]    [Pg.1104]    [Pg.1104]    [Pg.1104]    [Pg.1104]    [Pg.1104]    [Pg.1105]   