Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Advanced Experiments

A comprehensive text which discusses advanced experiments with particular reference to polymers. [Pg.1499]

The MOSFET, the most important microelectronic device, can be reduced in dimension to reach a minimum feature size of 0.1 micron but even lower dimensions (0.05 microns) are foreseen, as demonstrated by recent advanced experiments. [Pg.76]

Tuning the probe assures that the resonant frequency of the probe coil is the same as the RF frequency you will be using and matching the probe matches the probe coil as a load to the impedance (internal electrical resistance) of the amplifiers. This gives maximum efficiency of transfer of RF power from the amplifiers to your sample nuclei and maximum sensitivity in detecting the FID. Each sample modifies the resonant frequency and matching of the probe, so these have to be reoptimized with each new sample. Tuning the probe is not necessary for routine XH spectra, but for advanced experiments it is important if you wish to use standard values for pulse widths without the need to calibrate for each sample. [Pg.88]

There are more advanced experiments such as DEPT (Chapter 7) that observe 13 C and use the decoupler to supply high power, short duration ( hard ) pulses at the XH frequency. This requires full power from the decoupler, but the parameters dpwr andpll7 are avoided for these pulses. Setting decoupler power to the maximum might lead to disastrous mistakes because the decoupler can only deliver full power for short ( 10 pis) periods of time without burning up the decoupler, the probe, and the sample. Instead, the parameters pp (Varian) and p3 (Bruker) are used for the 90° pulse width for decoupler hard pulses and pplvl (Varian) and pl2 (Bruker) indicate the power level for short-duration high-power decoupler pulses. [Pg.150]

One of the important applications of butylcalix[4]arenes arises from their ability to trap alkali metal ions. In particular, Cs+-calixarene complexes have received much attention because of the need to remove the Cs radionucleotide from nuclear wastes. Benevelli et al. have used one-pulse solid state NMR experiments to directly observe Li, Na and Cs ions in the host cavity [52]. More advanced experiments, which allow the investigation of metal lattice interactions were also reported. Rotational-echo double resonance (REDOR) NMR is a useful tool for obtaining structural details of butylcalix[4]arene [53]. Gullion and coworkers used REDOR to determine the position of the... [Pg.115]

Other sensitive but less frequently occurring pharmaceutical nuclei such as phosphorus, bromine, and sodium can be used. The latter two are characterized by quadrupolar nuclear spin. Advanced experiments, such as multiple quantum magic angle spinning (MQMAS) may be required to obtain narrow signals in these instances.166,167... [Pg.66]

At present the situation regarding ICT skills in our university is not unfavorable, as indicated above our graduated master students are able, through repeated practice, to conduct a literature search, perform advanced experiments in computer-controlled equipment, write scientific reports, give oral and poster presentations, and perfonn modeling simulations using the appropriate ICT tools. [Pg.346]

A comprehensive text which discusses advanced experiments with particular reference to polymers. Fitzgerald J J (ed) 1999 Solid State NMR Spectroscopy of Inorganic Materials (Washington, DC American Chemical Society) Gives a range of current examples of solid state NMR applied to inorganic materials. [Pg.1499]

To understand how some of the advanced experiments work, it is helpful to develop an appreciation of what an excitation pulse does to the nuclei in the sample and how the magnetization of the sample nuclei behaves during the course of a pulsed experiment. At this point, we shall turn our attention to three of the most important advanced experiments. [Pg.532]

ABSTRACT While probing into the investigation mechanism for the accidents occurring in American coalmines, the differences of the enforcement basis and mechanisms on the coalmine accidents between China and USA are compared and analyzed. Furthermore, the problems of China in the accident investigation mechanism are reviewed in a scientific, independent and systematic approach. Then, the author suggests the American advanced experiences and operations should be learnt, and subsequently comes up with the countermeasures for improving the investigation mechanism of China. [Pg.693]

The Joint European Torus (JET), which represents the most advanced experiment on fusion at this time, has produced (9 November 1991) for the first time fusion energy equivalent to 2 MW for 2 s using a D-T (deuterium-tritium) plasma, with 10-15 per cent tritium. [Pg.225]

It is clear that in the future, advanced experiments and high-accuracy analytical equipment will further increase the ability to carry out the model discrimination for radical copolymerization. [Pg.438]

When a spectral plot is not available, the absorbance ratio method is a satisfactory method for characterizing a real sample, using both spectrophotometric and HPLC assays. In addition, better performance needs to be achieved in carrying out advanced experiments, such as solid-phase extraction and other purification techniques coupled with HPLC quantification, in order to improve the separation properties. " ... [Pg.2395]

The experimental equipment needed would normally be available around a reactor facility. As more advanced experiments are performed, the equipment required may become more complex. However, it should be possible to obtain the equipment from existing research or service applications. There is usually no need to acquire new equipment for educational purposes. [Pg.6]

Not surprisingly, the advanced experiments outlined in Sec. II.E employ more sophisticated data interpretation than the basic techniques, in order to extract the more detailed chemical and physical information discarded in the simpler experiments. [Pg.454]

Thus, the experiments contained in Chapter lOW are specifically tailored to challenge the more advanced undergraduate students, those who are already able to access the chemical literature. This chapter can also offer a special laboratory experience for those few beginning students who are particularly interested in the subject and wish to spend extra preparation time. The techniques involved are not, in most instances, any different from those used in the introductory microscale laboratory reactions described in Chapter 6, and therefore the manipulations involved should not be considered a barrier to undertaking any of the advanced experiments. The reaction conditions, however, are less forgiving to slight deviations from the suggested ones and the ultimate success of the transformations is less secure. [Pg.703]

More advanced experiments, such as ENDOR, electron spin echo envelope modulation (ESEEM), or relaxation measurements by pulsed ESR rely on a selective excitation of spins close to the resonance field. Usually, the powder ESR spectrum is much broader than the excitation bandwidth of the pulses, which is in the range between 2 and 10 G. In cases where one anisotropic interaction dominates the spectrum, the experiments thus select contributions only from certain orientations of the molecule with respect to the external magnetic field. Such orientation selection is more efficient and easier to interpret at a field that is high enough for the g anisotropy to dominate. Finally, the size of mw resonators scales with wavelength and thus scales inversely with frequency. At higher frequency, spectra can thus be measured with much smaller sample volumes, yet the concentration does not need to be significantly increased. [Pg.17]

Recently, Anderson has reported a rigid tri-porphyrin host able to associate with Cgo, C70, and also Cg6 with extremely high binding constant values such as logX = 6.2, 8.2, and >9, respectively (Figure 2.9c). The strong affinity of this trimer to bigger fullerenes cannot be measured by fluorescence titration, and it has been demonstrated with some advanced experiments. ... [Pg.56]

In spite of all the good reasons to delegate, some technical professionals never learn how to do it effectively. This failure hampers the success of the organization and hinders the individual s advancement. Experience reveals the following seven reasons, or more precisely, rationales for this reluctance. [Pg.131]

A more advanced experiment is the fabrication and electrical characterization of a Schottky nanodiode. While the fabrication of the device is the easy part, the electrical characterization and data analysis is relatively complex. In general, a Schottky diode is formed when a junction of a p-doped polymer with an n-doped inorganic semiconductor is formed. This construction can be achieved via electrochemical polymerization 6-9) or spin coating 10) the polymer onto the n-doped semiconducting substrate. In... [Pg.162]


See other pages where Advanced Experiments is mentioned: [Pg.22]    [Pg.27]    [Pg.93]    [Pg.1]    [Pg.121]    [Pg.272]    [Pg.245]    [Pg.138]    [Pg.80]    [Pg.49]    [Pg.609]    [Pg.599]    [Pg.417]    [Pg.320]    [Pg.188]    [Pg.431]    [Pg.224]    [Pg.1129]    [Pg.69]    [Pg.40]    [Pg.14]    [Pg.128]    [Pg.135]    [Pg.421]    [Pg.222]    [Pg.143]    [Pg.179]    [Pg.1532]   


SEARCH



Advanced Containment Experiments

Advanced Design-Implement Experiences

Advanced Methods of Theory-Experiment Comparison

Online advanced experiments

Superheat Advance Demonstration Experiment

© 2024 chempedia.info