Help the Project Manager in the preparation and the issue of an Addendum Report on the HAZOP or What-If reviews for recommendation(s) and resolutions or closeouts. [Pg.13]

Follow through on action items identified as part of the study review. Obtain resolution or close out of the recommendations. Prepare and issue any HAZOP or What-If Addendum Reports documenting recommendation resolutions or closeouts. [Pg.14]

Addendum Report Report which resolves any recommendations concluded from the HAZOP or What-If review Final Report. Issued before start-up of the facility and added to the Final Report as an addendum. [Pg.59]

The addendum report should be prepared by the project manager with help of the team leader. Addendum report is prepared and issued before start-up or operation of the facility or system. For existing facilities this is determined as a reasonable period (as determined by local management) for the recommendations to be resolved with... [Pg.63]

The Project Manager distributes copies of the Addendum report as follows ... [Pg.64]

In some instances legal and senior management should be provided with a copy of the Addendum report. [Pg.64]

Preliminary Report Draft Report Final Report Addendum Report... [Pg.65]

It is important to realize that a HAZOP or What-If safety review is not actually complete until all recommendations have been resolved and a close-out "Addendum" report is produced. [Pg.66]

There are several possible actions for each recommendation when listed in the addendum report ... [Pg.66]

The Project Manager should maintain and issue a action plan summary until all items are closed out. The HAZOP or What-If Addendum report is usually prepared from the action plan summaries. Items which are not closed out prior to the facility or project start-up should be addressed as part of the Pre-Startup-Safety-Review (PSSR). A copy of the action plant should be made available to operating, maintenance and other employees whose work assignments are in the process and who may be affected by the recommendations or actions. [Pg.69]

The cost estimating formula does not account for the cost to analyze recommendations, or issue an addendum report. Since the outcome of recommendations can vary tremendously, these costs cannot be estimated until the recommendations are produced. [Pg.77]

Addendum Report A supplement report issued after a final HAZOP or What-If review report documenting the resolution of recommendations from a HAZOP or What-If review. [Pg.123]

Jones, J.L., Kohan, S.M., and Semrau, K.J., "Mission Analysis for the Federal Fuels from Biomass Program. Volume VI Mission Addendum," report prepared by SRI International for DOE under Contract EY-76-C-03-0115 PA131 (January, 1979). [Pg.51]

International Covenant on Civil and Political Rights, Third periodic reports of states parties due in 1991, Addendum, Report Submitted by Sri Lanka, 18 July 1994, CCPR/C/70/Add.6, 27 September 1994. [Pg.40]

Addendum. In a later paper Manske and Marion report on L. annotinum var. acrifolium Fern., which they suggest should be raised to specific rank as L. acrifolium (Fern.) N. Comb., since its alkaloidal com stituents differ from those of L. annotinum. It contains annotinine as the... [Pg.754]

Canfield, Compatibility of Explosives with Polymers (III), An Addendum to Picatinny Arsenal Technical Report 2595 and PLASTEC Rept 33 , PLASTEC Rept 40 (1971)... [Pg.789]

We shall report hereafter three examples of measurement of heat capacity the first (of a crystal) with a negligible addendum the second (of a polymer) with a heavy addendum the third is the measurement of the carrier specific heat of a heavily doped semiconductor. [Pg.286]

In Table 12.1, the contributions to the heat capacity Csp of the addendum are shown specific heat data references are reported in ref. [20], A factor 1/3 was attributed to the heat capacity contribution of the elements linking the crystal to the frame [15], Note that the electron heat capacity of the NTD Ge 31 sensor was derived from the electron... [Pg.288]

The value of the heat capacity C was obtained as r G. These values were corrected subtracting the contribution Csp of the addendum. Heat capacity data are shown in Fig. 12.8, in which the ratio C/T is reported as a function of T2. [Pg.291]

An AVS 47 AC resistance bridge for the thermometer and a four-wire I-V source (Keitley 236) for the heater were used. The contributions to the addendum are reported in Table 12.2. [Pg.293]

EFSA (2008) Final addendum to the Draft Assessment Report (DAR), Bifenthrin, public version. Background document A, pp 685, European Food Safety Authority, Parma, http // www.efsa.europa.eu/en/scdocs/scdoc/186r.htm... [Pg.201]

This section should list any deviations from the initial study plan. The original study plan is often included as an addendum to the study report, but this is superfluous if the methods section is well written and complete. [Pg.300]

In Roberts report (3), a compilation of data to 1975 for over 3000 substances investigated as superconductors to different low temperatures, only 42 different oxide compositions are listed. These oxides can be classified into separate groups binary oxides =12 ternary oxides = 22 and multinary or complex oxides = 8. Of these, only 25 were found to superconduct and the highest superconducting transition temperature achieved in oxides was 2.3 K for nearly stoichiometric TiO. In 1978, Roberts presented (11) an addendum to his 1975 data set with the addition (or revision) of 8 new (mostly superconducting) oxides. [Pg.20]

Syncrude Canada Limited."Environmental Impact Assessment, Addendum to the 1973 Report, Volume... [Pg.82]

Anonymous. Final report on the safety assessment of PEG-20 sorbitan cocoate PEG-40 sorbitan diisostearate PEG-2, -5, and -20 sorbitan isostearate PEG-40 and -75 sorbitan lanolate PEG-10, -40, -44, -75 and -80 sorbitan laurate PEG-3, and -6 sorbitan oleate PEG-80 sorbitan palmitate PEG-40 sorbitan perisostearate PEG-40 sorbitan peroleate PEG-3, -6, -40, and -60 sorbitan stearate PEG-20, -30, -40, and -60 sorbitan tetraoleate PEG-60 sorbitan tetrastearate PEG-20 and -160 sorbitantriisostearate PEG-18 sorbitan trioleate PEG-40 and -50 sorbitol hexaoleate PEG-30 sorbitol tetraoleate laurate and PEG-60 sorbitol tetrastearate. Addendum to the final report on the safety assessment of... [Pg.35]

In an addendum the authors reported another similar case. [Pg.8]

UK Rapporteur Monograph (2000). Addendum to the Report Proposed Decision of the United Kingdom made to the European Commission under Article 7(1) of Regulation 3600/92. Summary, Scientific Evaluation and Assessment. [Pg.12]

Crick, M.J. Linsley, G.S. (1983) An assessment of the radiological impact of the Windscale reactor fire of October, 1957. National Radiological Protection Board, Chilton. Report R-135, Addendum. [Pg.54]


See other pages where Addendum reports is mentioned: [Pg.63]    [Pg.154]    [Pg.63]    [Pg.154]    [Pg.343]    [Pg.110]    [Pg.292]    [Pg.302]    [Pg.130]    [Pg.563]    [Pg.61]    [Pg.5]    [Pg.2524]    [Pg.387]    [Pg.113]    [Pg.31]    [Pg.133]    [Pg.792]   