Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Acceptance criteria selection

Test attributes procedures and acceptance criteria selection of batches testing frequency storage containers, conditions, and period, as well as data evaluation are discussed in great detail. Data evaluation considers out-of-specification results. Documentation covers protocols and protocol amendments, deviation reports, out-of-specification reports, test results and raw data, and stability reports. [Pg.19]

Consistent with these publications, the IAEA in 2002 issued a detailed report on Accident Analysis for Nuclear Power Plants (Safety Reports Series No. 23) that provides practical guidance for performing accident analysis. That report covers the steps required for accident analyses, i.e. selection of initiating events and acceptance criteria, selection of computer codes and modelling assumptions, preparation of input data and presentation of the calculation results. It also discusses aspects that need to be considered to ensure that the final accident analysis is of acceptable quality. Separate IAEA Safety Reports deal with specific features of individual reactor types, such as pressurized water reactors, boiling water reactors, pressurized heavy water reactors and RBMKs. [Pg.67]

Since in this study in vitro dissolution served as the response or objective function for optimizing the level of magnesium stearate, it would appear that the authors of Ref. 8 had a high degree of confidence in this method. The dissolution test method and acceptance criterion in the selected example is fairly common. Its in vivo relevance is assumed by many with a fair degree of confidence, as exemplified by the following perspective expressed in the USP [35] ... [Pg.340]

Natural selection. It selects the individuals destined to survive or to take part in mating. It implies the calculation of the fitness for all the members of a given population and a selection procedure, somehow analogous to the SA acceptance criterion, capable of tagging the members with highest probability of survival (thus containing some random element). [Pg.252]

During prestudy validation, the performance of the assay with respect to specificity and selectivity is confirmed with the most relevant compounds and matrices. Selectivity is expressed as acceptable recovery, using the same criteria that are applied during the assessment of accuracy. The recommended target acceptance criterion for selectivity is that acceptable recovery (e.g., 80 120% relative to buffer control) is obtained in at least 80% of the matrices evaluated. [Pg.90]

Compliance with the EN standards is the minimum acceptable criterion for conformity, so I ll start by identifying the appropriate standards (also see Essential Requirements). The science of selecting the appropriate standards can be simple or complicated depending on your experience and product type. Exercise care when identifying the proper standards that may apply to your product design. The selection of a product standard may be a relatively simple task, as for many Low-Voltage Directive (LVD) products, or cumbersome, as for some machines. You must consider the product s intended usage and make sure the product falls within the standard s scope. [Pg.46]

Equation (12) ensures that microscopic reversibility is satisfied. Dodd et al. proved that erroneous results are obtained if the number of geometric solutions and the Jacobian determinants are not included in the acceptance criterion [47a]. Since we bias our selection of CONROT solutions, we have added the solution weights to the acceptance enterion. It must te pointed out however, that a successful removal of the bias requires long simulation runs, in order for some of the solutions that are not favored energetically to be selected. [Pg.295]

The acceptance criterion for the resolution of GSI C-05 is that the plant designer shall select either the historic, conservative approach for predictions of decay heat employing the function described in ANS 5.0 (Proposed) or the recent, more realistic approach using the fission product decay heat function identified in ANS 5.1, in order to meet the requirements of 10 CFR 50.46. [Pg.292]

From the latter discussion, we can also easily identify the previously mentioned ratio of general selection probabilities (4.82) that can be used alternatively in the acceptance criterion (4.80) ... [Pg.119]

Assuming the 1% limit was set down in full cognizance of the statistics involved, the system suitability test must be regarded as failed because 2.43 > 1.74. This would be the legalistic interpretation under GMP rules. Statistically it would have made more sense to select the criterion as St <0.01 Xmean VFc 0.05,ft, °°) for acceptance and demanding, say, u > 5 in this particular case, s, could have been as large as 3.6. [Pg.71]

Algorithm 1 requires the a priori selection of a threshold, s, on the empirical risk, /en,p( X which will indicate whether the model needs adaptation to retain its accuracy, with respect to the data, at a minimum acceptable level. At the same time, this threshold will serve as a termination criterion for the adaptation of the approximating function. When (and if) a model is reached so that the generalization error is smaller than e, learning will have concluded. For that reason, and since, as shown earlier, some error is unavoidable, the selection of the threshold should reflect our preference on how close and in what sense we would like the model to be with respect to the real function. [Pg.178]

After the momenta are selected from the distribution (8.39), the dynamics is propagated by a standard leapfrog algorithm (any symplectic and time-reversible integrator is suitable). The move is then accepted or rejected according to a criterion based on the detailed balance condition... [Pg.296]

In general it is not possible to develop a complete treatment scenario that is optimal technically, financially and also with respect to environmental sustainability. A solution has to be found which is economically and technically feasible and also satisfies the criteria of environmental sustainability to the greatest possible extent. An additional criterion for the selection of a complete closed loop water system can be obtained if the net environmental benefits are compared with the extra costs of the closed loop system. In this way the extra environmental benefits per unit investment costs or operating costs can be calculated. In the final selection of a closed loop water system aspects dealing with acceptability and public environmental awareness also play an important role. [Pg.249]

An important point is the evaluation of the models. While most methods select the best model at the basis of a criterion like adjusted R2, AIC, BIC, or Mallow s Cp (see Section 4.2.4), the resulting optimal model must not necessarily be optimal for prediction. These criteria take into consideration the residual sum of squared errors (RSS), and they penalize for a larger number of variables in the model. However, selection of the final best model has to be based on an appropriate evaluation scheme and on an appropriate performance measure for the prediction of new cases. A final model selection based on fit-criteria (as mostly used in variable selection) is not acceptable. [Pg.153]


See other pages where Acceptance criteria selection is mentioned: [Pg.180]    [Pg.174]    [Pg.255]    [Pg.295]    [Pg.124]    [Pg.339]    [Pg.556]    [Pg.756]    [Pg.135]    [Pg.35]    [Pg.544]    [Pg.174]    [Pg.842]    [Pg.380]    [Pg.569]    [Pg.380]    [Pg.335]    [Pg.42]    [Pg.57]    [Pg.45]    [Pg.281]    [Pg.6]    [Pg.273]    [Pg.107]    [Pg.329]    [Pg.451]    [Pg.463]    [Pg.533]    [Pg.534]    [Pg.752]    [Pg.217]    [Pg.149]    [Pg.74]    [Pg.56]    [Pg.10]    [Pg.554]    [Pg.54]    [Pg.11]    [Pg.1283]    [Pg.381]   
See also in sourсe #XX -- [ Pg.293 ]




SEARCH



Select Criteria

Selection criteria

Selectivity criteria

© 2024 chempedia.info