AA lamp

Element Wavelength (nm) AAS Lamp current (mA) Flame AAS Furnace AAS (IL/ Atomiser 55 CTF ICP... [Pg.338]

Element Wavelength (run) AA Lamp current (mA) Elame AA Eurnace AA (IE755 GTE Atomiser) ICP... [Pg.17]

The flash lamp teclmology first used to photolyse samples has since been superseded by successive generations of increasingly faster pulsed laser teclmologies, leading to a time resolution for optical perturbation metliods tliat now extends to femtoseconds. This time scale approaches tlie ultimate limit on time resolution (At) available to flash photolysis studies, tlie limit imposed by chemical bond energies (AA) tlirough tlie uncertainty principle, AAAt > 2/j. [Pg.2946]

For quantitative analysis, the resolution of the spectral analyzer must be significantly narrower than the absorption lines, which are - 0.002 nm at 400 nm for Af = 50 amu at 2500°C (eq. 4). This is unachievable with most spectrophotometers. Instead, narrow-line sources specific for each element are employed. These are usually hoUow-cathode lamps, in which a cylindrical cathode composed of (or lined with) the element of interest is bombarded with inert gas cations produced in a discharge. Atoms sputtered from the cathode are excited by coUisions in the lamp atmosphere and then decay, emitting very narrow characteristic lines. More recendy semiconductor diode arrays have been used for AAS (168) (see Semiconductors). [Pg.317]

Atomic absorption spectroscopy of VPD solutions (VPD-AAS) and instrumental neutron activation analysis (INAA) offer similar detection limits for metallic impurities with silicon substrates. The main advantage of TXRF, compared to VPD-AAS, is its multielement capability AAS is a sequential technique that requires a specific lamp to detect each element. Furthermore, the problem of blank values is of little importance with TXRF because no handling of the analytical solution is involved. On the other hand, adequately sensitive detection of sodium is possible only by using VPD-AAS. INAA is basically a bulk analysis technique, while TXRF is sensitive only to the surface. In addition, TXRF is fast, with an typical analysis time of 1000 s turn-around times for INAA are on the order of weeks. Gallium arsenide surfaces can be analyzed neither by AAS nor by INAA. [Pg.355]

Spectral interferences in AAS arise mainly from overlap between the frequencies of a selected resonance line with lines emitted by some other element this arises because in practice a chosen line has in fact a finite bandwidth . Since in fact the line width of an absorption line is about 0.005 nm, only a few cases of spectral overlap between the emitted lines of a hollow cathode lamp and the absorption lines of metal atoms in flames have been reported. Table 21.3 includes some typical examples of spectral interferences which have been observed.47-50 However, most of these data relate to relatively minor resonance lines and the only interferences which occur with preferred resonance lines are with copper where europium at a concentration of about 150mgL 1 would interfere, and mercury where concentrations of cobalt higher than 200 mg L 1 would cause interference. [Pg.792]

Double-beam AA spectrophotometers are still marketed by instrument manufacturers. A double-beam system compensates for changes in lamp intensity and may require less frequent re-zeroing than a single-beam instrument. These considerations had more merit some years ago when hollow cathode lamps suffered from some instability. It should be noted, however, that the optical... [Pg.799]

FIGURE 12.4 Lycopene photodegradation in 0.02 M Triton X-100 aqueous solutions illuminated with a 150 W (> 380 nm) filament lamp. Inset evolution of the difference absorption spectrum (AA). [Pg.240]

By changing excitation source (e.g., hollow cathode lamps in AAS)... [Pg.80]

Laser flash photolysis experiments48,51 are based on the formation of an excited state by a laser pulse. Time resolutions as short as picoseconds have been achieved, but with respect to studies on the dynamics of supramolecular systems most studies used systems with nanosecond resolution. Laser irradiation is orthogonal to the monitoring beam used to measure the absorption of the sample before and after the laser pulse, leading to measurements of absorbance differences (AA) vs. time. Most laser flash photolysis systems are suitable to measure lifetimes up to hundreds of microseconds. Longer lifetimes are in general not accessible because of instabilities in the lamp of the monitoring beam and the fact that the detection system has been optimized for nanosecond experiments. [Pg.176]

Figure 3.1 Schematic diagram of an AAS spectrometer. A is the light source (hollow cathode lamp), B is the beam chopper (see Fig. 3.2), C is the burner, D the monochromator, E the photomultiplier detector, and F the computer for data analysis. In the single beam instrument, the beam from the lamp is modulated by the beam chopper (to reduce noise) and passes directly through the flame (solid light path). In a double beam instrument the beam chopper is angled and the rear surface reflective, so that part of the beam is passed along the reference beam path (dashed line), and is then recombined with the sample beam by a half-silvered mirror. Figure 3.1 Schematic diagram of an AAS spectrometer. A is the light source (hollow cathode lamp), B is the beam chopper (see Fig. 3.2), C is the burner, D the monochromator, E the photomultiplier detector, and F the computer for data analysis. In the single beam instrument, the beam from the lamp is modulated by the beam chopper (to reduce noise) and passes directly through the flame (solid light path). In a double beam instrument the beam chopper is angled and the rear surface reflective, so that part of the beam is passed along the reference beam path (dashed line), and is then recombined with the sample beam by a half-silvered mirror.
Several condensed 6-7 bicyclic systems have been prepared from AAs. Some Af -chloroacetylated AAs are photochemically transformed into heterocycles with a condensed seven-membered ring. For example, A-chloro-acetyl-D,L-w-tyrosine is easily cyclized into benzazepinone 109a on irradiation with a high-pressure mercury lamp (67JA1039 68JA776). [Pg.53]

A convenient method is the spectrometric determination of Li in aqueous solution by atomic absorption spectrometry (AAS), using an acetylene flame—the most common technique for this analyte. The instrument has an emission lamp containing Li, and one of the spectral lines of the emission spectrum is chosen, according to the concentration of the sample, as shown in Table 2. The solution is fed by a nebuhzer into the flame and the absorption caused by the Li atoms in the sample is recorded and converted to a concentration aided by a calibration standard. Possible interference can be expected from alkali metal atoms, for example, airborne trace impurities, that ionize in the flame. These effects are canceled by adding 2000 mg of K per hter of sample matrix. The method covers a wide range of concentrations, from trace analysis at about 20 xg L to brines at about 32 g L as summarized in Table 2. Organic samples have to be mineralized and the inorganic residue dissolved in water. The AAS method for determination of Li in biomedical applications has been reviewed . [Pg.324]

One often unsuspected source of error can arise from interference by the substances originating in the sample which are present in addition to the analyte, and which are collectively termed the matrix. The matrix components could enhance, diminish or have no effect on the measured reading, when present within the normal range of concentrations. Atomic absorption spectrophotometry is particularly susceptible to this type of interference, especially with electrothermal atomization. Flame AAS may also be affected by the flame emission or absorption spectrum, even using ac modulated hollow cathode lamp emission and detection (Faithfull, 1971b, 1975). [Pg.204]

Atomic absorption spectrometry (AA). This is a standard laboratory analytical tool for metals. The metal is extracted into a solution and then vaporized in a flame. A light beam with a wavelength absorbed by the metal of interest passes through the vaporized sample for example, to measure zinc, a zinc resonance lamp can be used so that the emission and absorbing wavelengths are perfectly matched. The absorption of the light by the sample is measured and Beer s law is applied to quantify the amount present. [Pg.620]

As we have seen, a narrow line source is required for AAS. Although in the early days vapour discharge lamps were used for some elements, these are rarely used now because they exhibit self-absorption. The most popular source is the hollow-cathode lamp, although electrodeless discharge lamps are popular for some elements. [Pg.18]

High intensity is not a source requirement in AAS and therefore electrodeless discharge lamps will not replace hollow-cathode lamps. However, for those elements that produce poor hollow-cathode lamps (notably arsenic... [Pg.20]


See other pages where AA lamp is mentioned: [Pg.317]    [Pg.319]    [Pg.608]    [Pg.609]    [Pg.23]    [Pg.564]    [Pg.276]    [Pg.282]    [Pg.27]    [Pg.28]    [Pg.309]    [Pg.235]    [Pg.243]    [Pg.244]    [Pg.245]    [Pg.50]    [Pg.53]    [Pg.77]    [Pg.266]    [Pg.126]    [Pg.21]   