Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Water samples composite sample

Typical Water - Sample Compositions From Tunnel Beds... [Pg.775]

Once the proper particle size was achieved, the water was removed from the sample prior to subjecting it to SFE. In the usual, preferred approach the analytical-size sample was taken from the water-blended composite sample, placed/weighed on filter paper, and dried in an oven (110 C) for one hour. A mortar and pestle shovdd be used to mfr the dehydrated sample with the diatomaceous earth, to further dry and disperse the sample. [Pg.450]

Figure 6.10. Projection of water sample compositions (calculated by minteqa2) onto the logaK+/aH+ vs. logasio2(a ) diagram at 12°C. Figure 6.10. Projection of water sample compositions (calculated by minteqa2) onto the logaK+/aH+ vs. logasio2(a ) diagram at 12°C.
Average of 10-day composite samples collected during water year 1969. [Pg.202]

Allophane and Imogolite. AUophane is an amorphous clay that is essentially an amorphous soHd solution of sUica, alumina, and water (82). In allophane less than one-half of the aluminum is held in tetrahedral coordinations and the Si02 to AI2O2 ratio typically varies between 1.3 and 2.0, but values as low as 0.83 have been reported. The typical morphology of allophane is cylindrical (37). AUophane may be associated with haUoysite, smectite minerals, or it may occur as a homogeneous mixture with evansite, an amorphous soHd solution of phosphoms, alumina, and water. Its composition, hydration, and properties vary. Chemical analyses of two allophane samples are given in Table 5. [Pg.200]

Waste water rules sometimes require that water conform to the limitations at all times. Under such rules, surges of non-conforming sewage are not permitted. Tests run on composite samples over a 24-hour period, for example, will then not be acceptable. [Pg.57]

DGGE Water samples collected from eight sites of three different lake zones and the Global Positioning System Microbial community composition and relationship between bacterial community structure and environmental factors [147]... [Pg.19]

Brown and Huffman [85] reported an investigation of the concentration and composition of nonvolatile hydrocarbons in Atlantic Ocean and nearby waters. Sea water samples were taken at depths of 1 and 10 m and the nonvolatile hydrocarbons were identified by mass spectrometric techniques. The results show that the nonvolatile hydrocarbons in Atlantic and nearby waters contained aromatics at lower concentrations than would be expected if the source of the hydrocarbons were crude oil or petroleum refinery products. Hydrocarbons appeared to persist in the water to varying degrees, with the most persistent being the cycloparaffins, then isoparaffins, and finally the aromatics. [Pg.390]

Fig. 29. SIMS profiles of total deuterium density in two composite samples subjected to a one hour deuteration in the same plasma product environment at 300°C (Johnson, 1988). Both samples had a substrate containing 2 x 10IH Sb/cm3 this was covered with an epitaxial layer containing 3 x 1018 As/cm3 for the upper curve, and with one containing 5x 10 7 As/cm3 for the lower curve. There was in both cases a little interdiffusion. All sample surfaces were prepared for deuteration by removing the oxide with a dilute HF etch, rinsing with distilled water, and blowing dry with heated nitrogen. Fig. 29. SIMS profiles of total deuterium density in two composite samples subjected to a one hour deuteration in the same plasma product environment at 300°C (Johnson, 1988). Both samples had a substrate containing 2 x 10IH Sb/cm3 this was covered with an epitaxial layer containing 3 x 1018 As/cm3 for the upper curve, and with one containing 5x 10 7 As/cm3 for the lower curve. There was in both cases a little interdiffusion. All sample surfaces were prepared for deuteration by removing the oxide with a dilute HF etch, rinsing with distilled water, and blowing dry with heated nitrogen.
McNeil VH, Cox ME (2000) Relationship between conductivity and analysed composition in a large set of natural surface-water samples, Queensland, Australia. Environ Geol 39 (12) 1325—1333... [Pg.119]

Step 2 Sample injection from autosampler into trap column 1 for 3 to 5 min using 100% pump 1. Sample is focused, filtered, and concentrated in trap column 1. Condition pumps 3 and 4 to 95% water in composition. Switching valve A = on switching valve B = on. [Pg.367]

Compositional changes in the formation water sampled from the Waarre C sandstone at the Otway Project pilot site provide information on the physical and chemical processes taking place during the injection and migration of C02. By... [Pg.153]

From the chemical compositions of water samples, the saturation index of calcite is calculated as follows ... [Pg.165]


See other pages where Water samples composite sample is mentioned: [Pg.186]    [Pg.194]    [Pg.405]    [Pg.379]    [Pg.354]    [Pg.198]    [Pg.202]    [Pg.767]    [Pg.560]    [Pg.38]    [Pg.162]    [Pg.240]    [Pg.106]    [Pg.263]    [Pg.944]    [Pg.541]    [Pg.256]    [Pg.322]    [Pg.47]    [Pg.467]    [Pg.191]    [Pg.1256]    [Pg.1459]    [Pg.103]    [Pg.139]    [Pg.151]    [Pg.163]    [Pg.228]    [Pg.36]    [Pg.285]    [Pg.318]    [Pg.23]    [Pg.207]    [Pg.503]    [Pg.124]   
See also in sourсe #XX -- [ Pg.3 ]




SEARCH



Composite sample

Composite sampling

Composite water sample

Composite water sample

Sample composition

© 2024 chempedia.info