Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Vaporization flame

Farwell, S. O., Liebowitz, D. P., Kagel, R. A., and Adams, D. F., Determination of total biogenic sulfur gases by filter/flash vaporization/flame photometry. Anal. Chem., 52, 2370-2375, 1980. [Pg.368]

The flash point of a petroleum liquid is the temperature to which it must be brought so that the vapor evolved burns spontaneously in the presence of a flame. For diesel fuel, the test is conducted according to a closed cup technique (NF T 60-103). The French specifications stipulate that the flash point should be between 55°C and 120°C. That constitutes a safety criterion during storage and distribution operations. Moreover, from an official viewpoint, petroleum products are classified in several groups according to their flash points which should never be exceeded. [Pg.249]

The autoignition temperature is the minimum temperature required for self-sustained combustion in the absence of an external ignition source. The value depends on specified test conditions. Tht flammable (explosive) limits specify the range of concentration of the vapor in air (in percent by volume) for which a flame can propagate. Below the lower flammable limit, the gas mixture is too lean to burn above the flammable limit, the mixture is too rich. Additional compounds can be found in National Fire Protection Association, National Fire Protection Handbook, 14th ed., 1991. [Pg.498]

Miscellaneous Atomization Methods A few elements may be atomized by a chemical reaction that produces a volatile product. Elements such as As, Se, Sb, Bi, Ge, Sn, Te, and Pb form volatile hydrides when reacted with NaBH4 in acid. An inert gas carries the volatile hydrides to either a flame or to a heated quartz observation tube situated in the optical path. Mercury is determined by the cold-vapor method in which it is reduced to elemental mercury with SnCb- The volatile Hg is carried by an inert gas to an unheated observation tube situated in the instrument s optical path. [Pg.415]

The principle of headspace sampling is introduced in this experiment using a mixture of methanol, chloroform, 1,2-dichloroethane, 1,1,1-trichloroethane, benzene, toluene, and p-xylene. Directions are given for evaluating the distribution coefficient for the partitioning of a volatile species between the liquid and vapor phase and for its quantitative analysis in the liquid phase. Both packed (OV-101) and capillary (5% phenyl silicone) columns were used. The GG is equipped with a flame ionization detector. [Pg.611]

Fundamentally, introduction of a gaseous sample is the easiest option for ICP/MS because all of the sample can be passed efficiently along the inlet tube and into the center of the flame. Unfortunately, gases are mainly confined to low-molecular-mass compounds, and many of the samples that need to be examined cannot be vaporized easily. Nevertheless, there are some key analyses that are carried out in this fashion the major one i.s the generation of volatile hydrides. Other methods for volatiles are discussed below. An important method of analysis uses lasers to vaporize nonvolatile samples such as bone or ceramics. With a laser, ablated (vaporized) sample material is swept into the plasma flame before it can condense out again. Similarly, electrically heated filaments or ovens are also used to volatilize solids, the vapor of which is then swept by argon makeup gas into the plasma torch. However, for convenience, the methods of introducing solid samples are discussed fully in Part C (Chapter 17). [Pg.98]

Other vapor introduction systems are discussed in Parts B and C (Chapters 16 and 17) because, although liquids and solids are ultimately introduced to the plasma flame as vapors, these samples are usually prepared differently from naturally gaseous ones. For example, electrothermal (oven) or laser heating of solids and liquids to form vapors is used extensively to get the samples into the plasma flame. At one extreme with very volatile liquids, no heating is necessary, but, at the other extreme, very high temperatures are needed to vaporize a sample. For convenience, the electrothermal and laser devices are discussed in Part C (Chapter 17) rather than here. [Pg.102]

Gases and vapors of volatile liquids can be introduced directly into a plasma flame for elemental analysis or for isotope ratio measurements. Some elements can be examined by first converting them chemically into volatile forms, as with the formation of hydrides of arsenic and tellurium. It is important that not too much analyte pass into the flame, as the extra material introduced into the plasma can cause it to become unstable or even to go out altogether, thereby compromising accuracy or continuity of measurement. [Pg.102]

Suitable inlets commonly used for liquids or solutions can be separated into three major classes, two of which are discussed in Parts A and C (Chapters 15 and 17). The most common method of introducing the solutions uses the nebulizer/desolvation inlet discussed here. For greater detail on types and operation of nebulizers, refer to Chapter 19. Note that, for all samples that have been previously dissolved in a liquid (dissolution of sample in acid, alkali, or solvent), it is important that high-purity liquids be used if cross-contamination of sample is to be avoided. Once the liquid has been vaporized prior to introduction of residual sample into the plasma flame, any nonvolatile impurities in the liquid will have been mixed with the sample itself, and these impurities will appear in the results of analysis. The problem can be partially circumvented by use of blanks, viz., the separate examination of levels of residues left by solvents in the absence of any sample. [Pg.104]

These factors make it necessary to reduce the amount of solvent vapor entering the flame to as low a level as possible and to make any droplets or particulates entering the flame as small and of as uniform a droplet size as possible. Desolvation chambers are designed to optimize these factors so as to maintain a near-constant efficiency of ionization and to flatten out fluctuations in droplet size from the nebulizer. Droplets of less than 10 pm in diameter are preferred. For flow rates of less than about 10 pl/min issuing from micro- or nanobore liquid chromatography columns, a desolvation chamber is unlikely to be needed. [Pg.107]

Solutions can be examined by ICP/MS by (a) removing the solvent (direct and electrothermal methods) and then vaporizing residual sample solute or (b) nebulizing the sample solution into a spray of droplets that is swept into the plasma flame after passing through a desolvation chamber, where excess solvent is removed. The direct and electrothermal methods are not as convenient as the nebulization inlets for multiple samples, but the former are generally much more efficient in transferring samples into the flame for analysis. [Pg.108]

In some cases, it may be convenient to dissolve a solid and present it for analysis as a solution that can be nebulized and sprayed as an aerosol (mixed droplets and vapor) into the plasma flame. This aspect of analysis is partly covered in Part B (Chapter 16), which describes the introduction of solutions. There are vaporization techniques for solutions of solids other than nebulization, but since these require prior evaporation of the solvent, they are covered here. There are also many solid samples that need to be analyzed directly, and this chapter describes commonly used methods to do so. [Pg.110]

The various heating methods produce a vapor that is a mixture of gas, very small droplets, and small particles of solid matter (particulates). Before droplets or particulates can coalesce, the whole vapor is swept into the plasma flame for analysis. Clearly, the closer the heating source is... [Pg.110]

Suffice it to say at this stage that the surfaces of most solids subjected to such laser heating will be heated rapidly to very high temperatures and will vaporize as a mix of gas, molten droplets, and small particulate matter. For ICP/MS, it is then only necessary to sweep the ablated aerosol into the plasma flame using a flow of argon gas this is the basis of an ablation cell. It is usual to include a TV monitor and small camera to view the sample and to help direct the laser beam to where it is needed on the surface of the sample. [Pg.112]

In a concentric-tube nebulizer, the sample solution is drawn through the inner capillary by the vacuum created when the argon gas stream flows over the end (nozzle) at high linear velocity. As the solution is drawn out, the edges of the liquid forming a film over the end of the inner capillary are blown away as a spray of droplets and solvent vapor. This aerosol may pass through spray and desolvation chambers before reaching the plasma flame. [Pg.142]

The sample solution is pumped (e.g., from the end of a liquid chromatographic column) through a capillary tube, near the end of which it is heated strongly. Over a short length of tube, some of the solvent is vaporized and expands rapidly. The remaining liquid and the expanding vapor mix and spray out the end of the tube as an aerosol. A flow of argon carries the aerosol into the plasma flame. [Pg.150]

Having assisted desolvation in this way, the carrier gas then carries solvent vapor produced in the initial nebulization with more produced in the desolvation chamber. The relatively large amounts of solvent may be too much for the plasma flame, causing instability in its performance and, sometimes, putting out the flame completely. Therefore, the desolvation chamber usually contains a second section placed after the heating section. In this second part of the desolvation chamber, the carrier gas and entrained vapor are strongly cooled to temperatures of about 0 to -10 C. Much of the vapor condenses out onto the walls of the cooled section and is allowed to drain away. Since this drainage consists only of solvent and not analyte solution, it is normally directed to waste. [Pg.152]

The previous discussion has centered on how to obtain as much molecular mass and chemical structure information as possible from a given sample. However, there are many uses of mass spectrometry where precise isotope ratios are needed and total molecular mass information is unimportant. For accurate measurement of isotope ratio, the sample can be vaporized and then directed into a plasma torch. The sample can be a gas or a solution that is vaporized to form an aerosol, or it can be a solid that is vaporized to an aerosol by laser ablation. Whatever method is used to vaporize the sample, it is then swept into the flame of a plasma torch. Operating at temperatures of about 5000 K and containing large numbers of gas ions and electrons, the plasma completely fragments all substances into ionized atoms within a few milliseconds. The ionized atoms are then passed into a mass analyzer for measurement of their atomic mass and abundance of isotopes. Even intractable substances such as glass, ceramics, rock, and bone can be examined directly by this technique. [Pg.284]

The gas or vapor to be examined is mixed with argon gas to constitute the needed flow of gas into the plasma flame, and the sample vapor or gas is swept along with this argon makeup gas. [Pg.396]


See other pages where Vaporization flame is mentioned: [Pg.17]    [Pg.465]    [Pg.98]    [Pg.119]    [Pg.17]    [Pg.465]    [Pg.695]    [Pg.315]    [Pg.696]    [Pg.465]    [Pg.3236]    [Pg.277]    [Pg.473]    [Pg.71]    [Pg.17]    [Pg.465]    [Pg.98]    [Pg.119]    [Pg.17]    [Pg.465]    [Pg.695]    [Pg.315]    [Pg.696]    [Pg.465]    [Pg.3236]    [Pg.277]    [Pg.473]    [Pg.71]    [Pg.257]    [Pg.254]    [Pg.357]    [Pg.1009]    [Pg.413]    [Pg.415]    [Pg.105]    [Pg.106]    [Pg.107]    [Pg.107]    [Pg.108]    [Pg.111]    [Pg.114]    [Pg.138]    [Pg.139]    [Pg.139]    [Pg.150]    [Pg.152]   
See also in sourсe #XX -- [ Pg.327 ]

See also in sourсe #XX -- [ Pg.327 ]




SEARCH



Combustion flame-chemical vapor

Combustion flame-chemical vapor condensation

Combustion flame-chemical vapor nanostructured materials

Flame acceleration, vapor cloud explosions

Flame solvent vapor entering

Flame-Chemical Vapor Condensation Process

Vapor-phase flame retardants

Vapor-phase flame-retardant mechanisms

© 2024 chempedia.info