Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Value extraction

Values extracted and in some cases rounded off from ttose cited in RaLinovict (ed.), Theimophysical Propeities of Neon, Ai gon, Kiypton and Xenon, Standards Press, Moscow, 1976. Ttis source contains values for tte compressed state for pressures up to 1000 bar, etc. t = triple point. Above tbe sobd line tbe condensed phase is solid below it, it is liquid. Tbe notation 5.646. signifies 5.646 X 10 . At 83.8 K, tbe viscosity of tbe saturated liquid is 2.93 X 10 Pa-s = 0.000293 Ns/ui . Tbis book was published in English translation by Hemisphere, New York, 1988 (604 pp.). [Pg.261]

Values extracted and occasionally rounded off from McCarty, Herd, and Roder, NBS Monogr. 168, 1981. t = triple point c = critical point. [Pg.287]

Values extracted and sometimes rounded off from tte tables of McCarty, Hord, and Roder, NBS Monogr. 168, 1981. This source contains an exhaustive tabulation of property values for botb tbe normal and tbe para forms of hydrogen, v = specific volume, mVkg h = specific enthalpy kj/kg s = specific entropy, kJ/(kg-K). [Pg.288]

Daphnia assay, the brine shrimps are exposed to different concentrations of toxicant, and the toxicity is expressed as the LCjo value. Extracts of cyanobacterial blooms and laboratory cultures, containing microcystins or anatoxin-a, have been found to be toxic towards brine shrimp," and fractionation of such extracts resulted in brine shrimp fatalities only with fractions containing microcystins." " ... [Pg.115]

The J(NH, H-C(/S)) values extracted from H-NMR spectra of 66 recorded in CD3OH between 298 and 353 K with 10-K increments, show little temperature dependence, and suggest that the overall 3i4-helical stracture is still present to a large extent at 353 K [164]. [Pg.53]

USEtox . In order to make sure that the results provided by USEtox are referred to China, the predicted emissions into the environmental compartments have been calculated using as a basis the information on the e-waste flow and presented in the chapter Tracking Global Hows of E-Waste Additives by Using Substance Flow Analysis, With a Case Study in China. Therefore these emissions are taken as inputs. Table 2 presents a summary with the main values extracted from the aforementioned chapter and used to run the USEtox model. [Pg.357]

In Table 27.3 and Figure 27.9 the results are summarized and compared with the best values extracted from the literature [94d]. [Pg.412]

This reduction in the proportion of profits consumed has important consequences for the economy as the simulation is repeated over subsequent periods. Although Bauer was able to demonstrate that expanded reproduction is sustainable over a four-year period Grossmann showed that if the simulation is continued for 35 years then this results in economic breakdown. Table 7.1 shows a steady fall in the proportion of profits consumed until, in year 34, only 2.16 per cent are consumed. The stringent demands of capital accumulation are fulfilled with constant and variable capital increasing by 10 and 5 per cent respectively throughout the 35-year period. The problem, however, is that with variable capital failing to keep pace with constant capital the pool of surplus value extracted from variable capital also fails to keep pace. [Pg.78]

Using the analytical framework developed by Samuelson and Wolfson (1986 69-70), the Bauer-Grossmann model, considered in Chapter 7, can be represented by a series of simple equations.1 The first relationship to be specified is that between net income (v,) and variable capital (Vt), where i represents a time subscript. Income consists of variable capital plus surplus value extracted at the rate s ... [Pg.108]

Table XIV Hazard classification of fluids according to their MESG1 and/or MIC2 values. (Extract from European Standard EN 50.014)... Table XIV Hazard classification of fluids according to their MESG1 and/or MIC2 values. (Extract from European Standard EN 50.014)...
Another empirical function that fits the concentration profile in Figure 3-8 well is shown in Figure 3-lOa. However, although the fit appears "perfect," the D values extracted as a function of concentration (Figure 3-lOb) are significantly different from those in Figure 3-9. This result occurs because the slope is not necessarily well fit by any empirical function. Furthermore, D at C near Coo (e.g., within 5% of Coo) cannot be obtained with any accuracy using the Boltzmann method. Therefore,... [Pg.220]

Fig. 10. Uranium dioxide solubility data obtained under nominally reducing conditions, corresponding to values extracted from the literature as given in the figure. Thermodynamic database for uranium from Grenthe et al. (1992) and Bruno Puigdomenech (1989). Fig. 10. Uranium dioxide solubility data obtained under nominally reducing conditions, corresponding to values extracted from the literature as given in the figure. Thermodynamic database for uranium from Grenthe et al. (1992) and Bruno Puigdomenech (1989).
A pH of 3 was selected as the standard operating pH for the CLLE because of biological growth at pH 7 and salt precipitation at higher pH values. Extraction recoveries at pH 3 appear to be equivalent to those at pH 7 for compounds that do not dissociate in that pH range. [Pg.574]

Literature data is almost entirely for small equipment whose capacity and efficiency cannot be scaled up to commercial sizes, although it is of qualitative value. Extraction processes are sensitive because they operate with small density differences that are sensitive to temperature and the amount of solute transfer. They also are affected by interfacial tensions, the large changes in phase flow rates that commonly occur, and even by the direction of mass transfer. For comparison, none of these factors is of major significance in vapor-liquid contacting. [Pg.476]

Commercialization and Value Extraction Here, a number of routes to the market are explored in addition to expanding ongoing DuPont businesses. An acquisition, a venture, licensing the technology, or a small stake in a startup all might be considered. [Pg.177]

The lifetimes obtained from a preliminary analysis are summarized in Table 1 which also includes the B(E2) values extracted from the lifetime data. Fig. 2 shows a plot of B(E2) s (in Weisskopf Units) vs. spin of the depopulating state. [Pg.244]

Using a recoil separation technique, however, [STE85] very clean spectra (Fig. 4b) could be obtained. The B(E2) values extracted for I90 i92pt) perfectly extend the trend observed in the heavier isotopes (Fig. 3). [Pg.401]

Successful application of the AOM parametrization scheme for interpretation of the electronic spectroscopy data based on the values extracted from experiment [159] demonstrates that the general parametrization scheme eq. (2.99) implied by the AOM, most probably reflects some general features of the electronic structure of the good fraction of TMCs. However, numerical estimates of its parameters according to formula eq. (2.99) were not particularly successful. As a result the AOM requires for its application large parameter sets (for the cells) specific for each pair of metal - ligand, which makes the parametrization boundless. The AOM parameters remain empirical quantities just as the 10.Dgs were in the original CFT. [Pg.151]


See other pages where Value extraction is mentioned: [Pg.530]    [Pg.78]    [Pg.261]    [Pg.1759]    [Pg.441]    [Pg.407]    [Pg.84]    [Pg.319]    [Pg.138]    [Pg.371]    [Pg.372]    [Pg.638]    [Pg.119]    [Pg.20]    [Pg.88]    [Pg.309]    [Pg.356]    [Pg.78]    [Pg.522]    [Pg.916]    [Pg.198]    [Pg.429]    [Pg.97]    [Pg.20]    [Pg.89]   
See also in sourсe #XX -- [ Pg.24 , Pg.362 ]




SEARCH



© 2024 chempedia.info