Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ultraviolet-visible spectroscopy analysis

Several spectroscopic techniques, namely, Ultraviolet-Visible Spectroscopy (UV-Vis), Infrared (IR), Nuclear Magnetic Resonance (NMR), etc., have been used for understanding the mechanism of solvent-extraction processes and identification of extracted species. Berthon et al. reviewed the use of NMR techniques in solvent-extraction studies for monoamides, malonamides, picolinamides, and TBP (116, 117). NMR spectroscopy was used as a tool to identify the structural parameters that control selectivity and efficiency of extraction of metal ions. 13C NMR relaxation-time data were used to determine the distances between the carbon atoms of the monoamide ligands and the actinides centers. The II, 2H, and 13C NMR spectra analysis of the solvent organic phases indicated malonamide dimer formation at low concentrations. However, at higher ligand concentrations, micelle formation was observed. NMR studies were also used to understand nitric acid extraction mechanisms. Before obtaining conformational information from 13C relaxation times, the stoichiometries of the... [Pg.80]

A solvent for ultraviolet/visible spectroscopy must be transparent in the region of the spectrum where the solute absorbs and should dissolve a sufficient quantity of the sample to give a well-defined analyte spectrum. In addition, we must consider possible interactions of the solvent with the absorbing species. For example, polar solvents, such as water, alcohols, esters, and ketones, tend to obliterate vibration spectra and should thus be avoided to preserve spectral detail. Nonpolar solvents, such as cyclohexane, often provide spectra that more closely approach that of a gas (compare, for example, the three spectra in Figure 24-14). In addition, the polarity of the solvent often influences the position of absorption maxima. For qualitative analysis, it is therefore important to compare analyte spectra with spectra of known compounds measured in the same solvent. [Pg.788]

NMR is not, of course, the only analytical technique used to establish the composition and microstructure of polymeric materials. Others include >66 ultraviolet-visible spectroscopy (UV-Vis), Raman spectroscopy, and infrared (IR) spectroscopy. IR and Raman spectroscopy are particularly useful, when by virtue of cross-linking (see. e.g. Chapter 9), or the presence of rigid aromatic units (see Chapter 4). the material neither melts nor dissolves in any solvent suitable for NMR. The development of microscopy based on these spectroscopic methods now makes such analysis relatively simple (see below). Space precludes a detailed account of these and many other techniques familiar to the organic chemist. Instead we focus for the remainder of the chapter on some of the techniques used to characterize the physical properties of polymeric materials. [Pg.9]

Despite these apparent limitations, fluorescence methods are employed for the determination of a wide variety of compounds. The selectivity of these analyses arises from the choice of both excitation and emission wavelengths, whereas the sensitivity of the analyses arises from the fact that absolute as opposed to relative measurements of light emission are made. This can be compared to ultraviolet-visible spectroscopy, where the ratio of incident to transmitted light is determined. Fluorescence measurements also have the advantage of a wide linear range of analysis. [Pg.466]

Quantitative infrared spectroscopy suffers certain disadvantages when compared with other analytical techniques and thus it tends to be confined to specialist applications. However, there are certain applications where it is used because it is cheaper or faster. The technique is often used for the analysis of one component of a mixture, particularly when the compounds in the mixture are alike chemically or haye very similar physical properties, e.g. structural isomers. In these cases, analysis by using ultraviolet/visible spectroscopy is difficult because the spectra of the components will be almost identical Chromatographic analysis may be of limited use because the separation of isomers, for example, is difficult to achieve. The infrared spectra of isomers are usually quite different in the fingerprint region. Another advantage of the infrared technique is that it is non-destructive and requires only a relatively small amount of sample. [Pg.85]

The ultraviolet-visible method is useful for the study of electronic transitions in molecules and atoms. Although various forms of ultraviolet-visible spectroscopy can be used to study a myriad of important chemical and physical properties, we will be most concerned with its use in quantitative analysis. It is probably the single most frequently used analytical method, with the possible exception of the analytical balance. For example, a single clinical analysis laboratory in a major hospital may perform a million chemical analyses a year, primarily on serum and urine, and about 707o of these tests are done by ultraviolet-visible absorption spectroscopy. Atomic absorption and emission spectroscopy (Chaps. 10 and 11) is used primarily to analyze for metallic elements in a variety of matrices—serum, natural waters, tissues, and so forth. [Pg.153]

Analytical techniques used in qualitative analysis include flame tests (Chapter 2) and precipitation reactions (Chapters 3 and 13). Analytical techniques used in quantitative analysis include titrations (Chapter 1), inductively coupled plasma (ICP) spectroscopy (Chapter 22 on the accompanying website), ultraviolet—visible spectroscopy (Chapter 23 on the accompanying website), infrared spectroscopy and various chromatographic techniques (Chapter 23). Analytical techniques used in structural analysis include NMR, IR spectroscopy, mass spectrometry and visible—ultraviolet spectroscopy. Important areas that employ analytical techniques include ... [Pg.410]

FIGURE 2.4 Different strategies for performing BIA. (AS, atomic spectroscopy MS, mass spectrometry UV/Vis, ultraviolet-visible spectroscopy.) (Modified with permission from J. Ruzicka, Flow Injection Analysis, 2014, http //www.flowinjectiontutorial.com.)... [Pg.42]

Davidson et characterized perflurotetradecahydrophenanthroline oligomers using a combination of nuclear magnetic resonance spectroscopy, electron spin resonance spectroscopy for chemical analysis and time of flight secondary ion mass spectrometry, infrared spectroscopy and ultraviolet-visible spectroscopy. [Pg.39]

Low-temperature, photoaggregation techniques employing ultraviolet-visible absorption spectroscopy have also been used to evaluate extinction coefficients relative to silver atoms for diatomic and triatomic silver in Ar and Kr matrices at 10-12 K 149). Such data are of fundamental importance in quantitative studies of the chemistry and photochemistry of metal-atom clusters and in the analysis of metal-atom recombination-kinetics. In essence, simple, mass-balance considerations in a photoaggregation experiment lead to the following expression, which relates the decrease in an atomic absorption to increases in diatomic and triatomic absorptions in terms of the appropriate extinction coefficients. [Pg.106]

The use of ultraviolet (UV) spectroscopy for on-line analysis is a relatively recent development. Previously, on-line analysis in the UV-visible (UV-vis) region of the electromagnetic spectrum was limited to visible light applications such as color measurement, or chemical concentration measurements made with filter photometers. Three advances of the past two decades have propelled UV spectroscopy into the realm of on-line measurement and opened up a variety of new applications for both on-line UV and visible spectroscopy. These advances are high-quality UV-grade optical fiber, sensitive and affordable array detectors, and chemometrics. [Pg.81]

F.C. Jentoft, Ultraviolet-Visible-Near Infrared Spectroscopy in Catalysis Theory, Experiment, Analysis, and Application Under Reaction Conditions, Adv. CataL, 52, 129-211 (2009). [Pg.104]


See other pages where Ultraviolet-visible spectroscopy analysis is mentioned: [Pg.7]    [Pg.7]    [Pg.163]    [Pg.772]    [Pg.384]    [Pg.379]    [Pg.218]    [Pg.384]    [Pg.296]    [Pg.357]    [Pg.474]    [Pg.224]    [Pg.215]    [Pg.4]    [Pg.3905]    [Pg.313]    [Pg.874]    [Pg.12]    [Pg.245]    [Pg.462]    [Pg.12]    [Pg.134]    [Pg.19]    [Pg.213]    [Pg.151]    [Pg.310]    [Pg.13]    [Pg.150]    [Pg.66]    [Pg.120]    [Pg.70]    [Pg.76]    [Pg.178]   


SEARCH



Analysis spectroscopy

Spectroscopy ultraviolet visible

Ultraviolet analysis

Ultraviolet spectroscopy

Ultraviolet-visible

© 2024 chempedia.info