Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Treatment surface composition

Cassie [39] extended Wenzel s treatment to composite surfaces. His treatment can be applied to a rough surface incompletely wetted by a liquid so that it consists of an area fraction f wetted and /2 unwetted surface. Then ... [Pg.330]

It is hardly surprising that the preparation of surfaces of plain specimens for stress-corrosion tests can sometimes exert a marked influence upon results. Heat treatments carried out on specimens after their preparation is otherwise completed can produce barely perceptible changes in surface composition, e.g. decarburisation of steels or dezincification of brasses, that promote quite dramatic changes in stress-corrosion resistance. Similarly, oxide films, especially if formed at high temperatures during heat treatment or working, may influence results, especially through their effects upon the corrosion potential. [Pg.1375]

The simplest technique introduced by Young as early as 1805 [18] is the measurement of the contact angle as a measure of surface tension and surface energy [1,19, 20,21], In many cases this gives an indication of surface composition and can be used to observe changes in composition, structure and/or roughness at the surface during a particular surface treatment. A quantitative description or distinction between different parameters is hardly possible in most cases. [Pg.365]

XPS Analysis. The ultrahigh vacuum (OHV) catalyst treatment-surface analysis system employed to characterize and treat the cobalt catalysts has been described previously ( 1, 2 The catalyst treatment and data analysis procedures have also been described (JJ. Briefly, the samples were treated in quartz reactors and then transferred under UHV into a modified Hewlett-Packard 5950A BSCA spectrometer for emalysis. Peak areas were normalized with theoretical cross-sections (Z) to obtain relative atomic compositions. [Pg.145]

The chapter is divided into two subsections the first of which deals with the characterization of electrodes as prepared prior to any electrochemical treatment. The knowledge of the actual surface composition of the fresh electrodes is needed to optimize preparation conditions and to be able to correlate electrochemical performance with surface properties. In Section 3.2 the application of XPS to the elucidation of electrochemical reaction mechanisms will be demonstrated. Here XPS monitors possible changes after controlled electrochemical treatment. [Pg.91]

XPS has been used by several authors to identify the surface and bulk composition of ruthenium based, valve metal stabilized DSA electrodes for chlorine evolution. Augustynski et al. [45] investigated the composition of Ru02-Ti02 electrodes before and after electrochemical treatment. They found a surface composition which deviated significantly from that of the bulk. The Ru/Ti ratio corresponded to 0.15 at the surface while in the bulk 0.28 was measured. Similar results were obtained by De Battisti et al. [46] for Ru02-Ti02 electrodes with different composition ratios on Ti substrates. Fig. 10 shows the Ru/Ti ratio for different solution compositions as a function of the depth. [Pg.92]

Fig. 23. Surface composition x of a Rujr,- alloy electrode after electrochemical treatment at different potentials for 5 min in 0.5 mol L-1 H2S04. Electron emission angle 90°. After [82],... Fig. 23. Surface composition x of a Rujr,- alloy electrode after electrochemical treatment at different potentials for 5 min in 0.5 mol L-1 H2S04. Electron emission angle 90°. After [82],...
GaAs, CuInS2, CuInSe2- Semiconductor electrodes have received increasing attention as a consequence of their potential application in photoelectrochemical energy conversion devices. In order to achieve optimum efficiency, the knowledge of the surface composition plays a crucial role. Surface modifications may occur during operation of the photo electrode, or may be the result of a chemical or electrochemical treatment process prior to operation. [Pg.122]

It is clear from the change in activity over this composition range that the surface composition of the Pd-Rh crystallites varied and, as expected, the direction of change indicates an increasing Rh surface content (Fig. 27). There is a maximum in activity at 52% Rh, but at slightly smaller Rh content the rate is distinctly less these anomalous results (open circles in Fig. 27) are explained by the following treatment of the data. The surface composition was equated with the composition corresponding to the observed lattice constant of phase I. In Fig. 28 the catalytic activity... [Pg.175]

The types of macrocycles most studied in which the active metal center is believed to be retained include Co, Fe, Ru porphyrins and related macrocycles. In these studies the optimal pyrolysis temperature is often reported to be between 400-800 °C. Above these temperatures, the active site begins to be destroyed, and activity decreases.49 An array of characterization techniques have been used to support these claims. XPS analysis has demonstrated that at the highest activity of samples, the surface composition of metal and nitrogen is also at its highest.78,96 Above the optimal treatment temperature, nitrogen and metal begin to disappear from the surface. Furthermore, Mossbauer spectroscopy and XAS have been used to... [Pg.345]

Dyer used a tandem RAIRS/X-ray photoelectron spectroscopy (XPS) technique to quantify the composition of these mixed brushes at the air/hquid interface and within the bulk film. In this case XPS was used to determine the surface composition of the film after each solvent treatment, hi particular. [Pg.62]

A quantitative surface compositional analysis requires the comparison of the experimental yield of the individual clusters with corresponding yields obtained theoretically this may be done by numerical simulation of the complex collision process but the accuracy of the result cannot yet be ascertained. The accuracy of the compositional analysis depends to some extent on such poorly known factors as the interatomic potential, ionization cross-sections and quantum-mechanical corrections to a treatment based on classical trajectories. [Pg.44]

Different 5 s after equal sintering treatments point to different surface compositions. [Pg.73]

Williams and Boudart (29) measured the surface composition of Ni-Au alloys that had been preequilibrated above the miscibility gap and subsequently generated. They found large enrichments in gold. The surface composition measurements fit the surface enrichment calculated according to Eq. (8) rather well. They report enhancements of the nickel concentration by treatment with oxygen. [Pg.86]

For quenching experiments, which were necessary to freeze-in the equilibrium states between the phase bands, the samples were reheated in a vacuum furnace under 500 mbar N2 to the original annealing temperature and dropped onto a copper plate kept below 470 K (200°C). With this treatment the Group 5 transition metal nitrides underwent a slight change in surface composition because it was impossible to adjust the appropriate nitrogen pressures. This, however, did not influence the compositions at the interface boundaries inside the diffusion couples. [Pg.57]


See other pages where Treatment surface composition is mentioned: [Pg.160]    [Pg.204]    [Pg.806]    [Pg.14]    [Pg.160]    [Pg.204]    [Pg.806]    [Pg.14]    [Pg.295]    [Pg.1]    [Pg.2]    [Pg.47]    [Pg.43]    [Pg.280]    [Pg.1182]    [Pg.243]    [Pg.118]    [Pg.225]    [Pg.104]    [Pg.80]    [Pg.94]    [Pg.122]    [Pg.122]    [Pg.178]    [Pg.494]    [Pg.171]    [Pg.556]    [Pg.73]    [Pg.191]    [Pg.191]    [Pg.192]    [Pg.460]    [Pg.20]    [Pg.278]    [Pg.354]    [Pg.197]    [Pg.67]    [Pg.230]   
See also in sourсe #XX -- [ Pg.160 ]




SEARCH



Available Treatments for Composite Surfaces

Composite surface

Composite surface treatment

Composite surface treatment

Effect of Surface Treatment and Sizing on Composite Properties

Heat treatment, surface composition

Surface Treatments of Fibers and Effects on Composite Properties

Surface treatment of composites

© 2024 chempedia.info