Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Transport measurement procedure

Metrological attestation as the procedure that ensures reproducibility and comparability of the results of measurements is specified in GOST 8.010-90 State System of Measurements. Procedures of Measurements Implementation didn t find wide use in NDT. In airspace industry, railway and naval transport the requirements of approval of test procedures is in force more than 20 years. In chemical and oil-chemical sectors the similar requirements were less explicit. In some industries, for example in building GOST 8.010-90 was not put into account. [Pg.960]

Measuring procedure Procedure for sampling and analyzing one or more chemical agents in the air, including the storage and transportation of the sample to the laboratory. [Pg.1458]

In whole tissue or cell monolayer experiments, transcellular membrane resistance (Rm = Pm1) lumps mucosal to serosal compartment elements in series with aqueous resistance (R = P ). The operational definition of Lm depends on the experimental procedure for solute transport measurement (see Section VII), but its magnitude can be considered relatively constant within any given experimental system. Since the Kp range dwarfs the range of Dm, solute differences in partition coefficient dominate solute differences in transcellular membrane transport. The lumped precellular resistance and lumped membrane resistance add in series to define an effective resistance to solute transport ... [Pg.173]

In this article, magnetic resonance imaging (MRI) technique is described as a diagnostic tool for in-situ visualization of water content in the membrane under fuel cell operation.7-30 Demonstrative applications and measurement procedure using MRI techniques are presented with discussion on water transport involved in PEMFCs. [Pg.202]

To achieve the required quality, the chemist should be involved from the beginning of the process, when the needs of the users of results are defined, until the final report is delivered. In practice, therefore, the analytical chemist has to be consulted at every stage of the process sample selection, sample storage, and transport procedures, the parameters to be analyzed, and the level of accuracy and precision necessary for an adequate response to be given. This will enable the analyst to set up a scientifically and economically adapted and accepted measurement procedure for the intended purpose as required by the QA system. Moreover, implementation of this system must guarantee that all necessary QC measures can be anticipated, so that the entire quality cycle is under control.4... [Pg.391]

A comparison of these three calculation procedures is given in Table 4.1, in which column 3 has been roughly calculated with a 20% increase per 10°C. Since the accuracy of mass transport measurements is 5-10%, these approximate calculations according to [422] are sufficient. [Pg.130]

Labeling requirements for excipient packages are subject to applicable national and international regulatory requirements, which may include transportation and safety measures. Procedures must be employed to protect the quality and purity of the excipient when it is packaged, and to assure that the correct label is applied to all containers. A good system of labeling should have, at a minimum, the following features ... [Pg.192]

The measurements were performed using a microcontroller equipped multipotentiostat The multipotentiostat has a capacity for up to 16 independent working electrodes providing the different potentials to the electrodes The microcontroller is able to perform all electrochemical measurement procedures, such as cyclic voltammetry, difference puls voltammetry, chronoamperometry and also control the analyte dosage and transport via pumps and valves... [Pg.251]

In spite of precise measuring procedures and careful evaluation of the data, the accuracy of analytical data is highly dependent on the sampling procedure, transportation to the laboratory, choice of a representative laboratory sample and the sample preparation procedure (Figure 3.168) Even powerful instrumental analysis cannot correct errors that have already occurred. [Pg.478]

Unless ordered otherwise, the nurse should save all stools that are passed after the drug is given. It is important to visually inspect each stool for passage of the helminth. If stool specimens are to be saved for laboratory examination, the nurse follows hospital procedure for saving the stool and transporting it to the laboratory. If the patient is acutely ill or has a massive infection, it is important to monitor vital signs every 4 hours and measure and record fluid intake and output. The nurse observes the patient for adverse drug reactions, as well as severe episodes of diarrhea. It is important to notify the primary health care provider if these occur. [Pg.140]

A soil sample was taken from a field, transported back to the laboratory by road and stored for three weeks prior to analysis. The analytical procedure consisted of drying the soil in an oven at 100°C for 24 h before the analyte was extracted using 200 cm of dichloromethane. This extract was reduced in volume to 200 til and a 20 p.l aliquot then analysed by HPLC. A calibration was set up by measuring the response from a number of solutions containing known concentrations of the analyte. The resnlt obtained from the unknown , after suitable mathematical manipulation, indicated the original soil sample contained 20 0.05 mgkg of the analyte. Comment on the accuracy of this result. [Pg.46]

Additional considerations, e.g. relating to labelling, information supply, emergency procedures, arise when marketing and transporting chemicals. While — as with Chapter 11 and with control measures generally — what is required will vary with specific legislation, basic requirements are summarized in Chapter 12. [Pg.3]


See other pages where Transport measurement procedure is mentioned: [Pg.180]    [Pg.247]    [Pg.627]    [Pg.268]    [Pg.474]    [Pg.360]    [Pg.5]    [Pg.147]    [Pg.671]    [Pg.227]    [Pg.172]    [Pg.1018]    [Pg.217]    [Pg.268]    [Pg.245]    [Pg.581]    [Pg.581]    [Pg.126]    [Pg.2814]    [Pg.2826]    [Pg.510]    [Pg.1878]    [Pg.41]    [Pg.613]    [Pg.596]    [Pg.502]    [Pg.61]    [Pg.267]    [Pg.234]    [Pg.44]    [Pg.139]    [Pg.596]    [Pg.34]    [Pg.180]    [Pg.181]    [Pg.183]    [Pg.183]   
See also in sourсe #XX -- [ Pg.387 , Pg.389 ]




SEARCH



Transport measurements

© 2024 chempedia.info