Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tracer limitations

At higher flow rates the dispersion of the tracer and the lower limit for time resolution of the concentration versus time distribution limits the accuracy to better than dt2%. [Pg.1055]

After having proved the principles a dynamic test facility has been constructed. In this facility it is possible to inject 3 tracers in a flownng liquid consisting of air, oil and water. By changing the relative amounts of the different components it is possible to explore the phase diagram and asses the limits for the measurement principle. Experiments have confirmed the accuracy in parameter estimation to be below 10%, which is considered quite satisfactorily for practical applications. The method will be tested on site at an offshore installation this summer. [Pg.1057]

Following the movement of airborne pollutants requires a natural or artificial tracer (a species specific to the source of the airborne pollutants) that can be experimentally measured at sites distant from the source. Limitations placed on the tracer, therefore, governed the design of the experimental procedure. These limitations included cost, the need to detect small quantities of the tracer, and the absence of the tracer from other natural sources. In addition, aerosols are emitted from high-temperature combustion sources that produce an abundance of very reactive species. The tracer, therefore, had to be both thermally and chemically stable. On the basis of these criteria, rare earth isotopes, such as those of Nd, were selected as tracers. The choice of tracer, in turn, dictated the analytical method (thermal ionization mass spectrometry, or TIMS) for measuring the isotopic abundances of... [Pg.7]

Radiochemical tracers, compounds labeled with radioisotopes (qv), have become one of the most powerful tools for detection and analysis in research, and to a limited extent in clinical diagnosis (see Medical IMAGING TECHNOLOGY). A molecule or chemical is labeled using a radioisotope either by substituting a radioactive atom for a corresponding stable atom in the compound, such as substituting for H, for or for P, and for for... [Pg.437]

Radioactive tracers account for about 20% of the worldwide market for consumables and reagents for life science research. In 1994 the value was estimated at about 300 million. The principal fuU line manufacturers are Du Pont—NEN Research Products (Boston, Massachusetts) and Amersham International (Amersham, U.K.). These companies share roughly equaHy about 85% of the radiochemicals worldwide market. In addition to an extensive line of catalog products, these suppHers offer custom labeling and custom synthesis services. The rest of the market is shared by producers of a limited range of products or services, such as ICN Biomedicals (Costa Mesa, California) and American Radiolabeled Chemicals (St. Louis, Missouri). [Pg.439]

A two-site immunometric assay of undecapeptide substance P (SP) has been developed. This assay is based on the use of two different antibodies specifically directed against the N- and C-terminal parts of the peptide (95). Affinity-purified polyclonal antibodies raised against the six amino-terminal residues of the molecule were used as capture antibodies. A monoclonal antibody directed against the carboxy terminal part of substance P (SP), covalently coupled to the enzyme acetylcholinesterase, was used as the tracer antibody. The assay is very sensitive, having a detection limit close to 3 pg/mL. The assay is fiiUy specific for SP because cross-reactivity coefficients between 0.01% were observed with other tachykinins, SP derivatives, and SP fragments. The assay can be used to measure the SP content of rat brain extracts. [Pg.247]

Tracer Diffusivity Tracer diffusivity, denoted by D g is related to both mutual and self-diffusivity. It is evaluated in the presence of a second component B, again using a tagged isotope of the first component. In the dilute range, tagging A merely provides a convenient method for indirect composition analysis. As concentration varies, tracer diffusivities approach mutual diffusivities at the dilute limit, and they approach selr-diffusivities at the pure component limit. That is, at the limit of dilute A in B, D g D°g and... [Pg.592]

Multicomponent Mixtures No simple, practical estimation methods have been developed for predicting multicomponent hquid-diffusion coefficients. Several theories have been developed, but the necessity for extensive activity data, pure component and mixture volumes, mixture viscosity data, and tracer and binaiy diffusion coefficients have significantly limited the utihty of the theories (see Reid et al.). [Pg.600]

Graham-Uranoff They studied multicomponent diffusion of electrolytes in ion exchangers. They found that the Stefan-Maxwell interaction coefficients reduce to limiting ion tracer diffusivities of each ion. [Pg.600]

The use of various statistical techniques has been discussed (46) for two situations. For standard air quality networks with an extensive period of record, analysis of residuals, visual inspection of scatter diagrams, and comparison of cumulative frequency distributions are quite useful techniques for assessing model performance. For tracer studies the spatial coverage is better, so that identification of meiximum measured concentrations during each test is more feasible. However, temporal coverage is more limited with a specific number of tests not continuous in time. [Pg.334]

This gives a direct measure of the benefits obtained by the hood. In practice, the best way to determine the occupational hygiene efficiency is to measure the actual concentrations in the operator s breathing zone for those two cases. A tracer can also be used with the limitations described above. [Pg.1019]

A modem variant is to count the number of atoms directly in a mass spectrometer.) The practical limit is about 50000 y since by this time the activity has fallen to about 0.2% of its original valuable and becomes submerged in the background counts. is also extremely valuable as a radioactive tracer for mechanistic studies using labelled compounds, and many such compounds, particularly organic ones, are commercially available (p. 310). [Pg.277]

Solution This solution illustrates a possible definition of the delta function as the limit of an ordinary function. Disturb the reactor with a rectangular tracer pulse of duration At and height A/t so that A units of tracer are injected. The input signal is Cm = 0, t < 0 = A/Af, 0 < t < At ... [Pg.546]

Pulse shapes other than rectangular can be used to obtain the same result. Triangular or Gaussian pulses could be used, for example. The Umit must be taken as the pulse duration becomes infinitesimally short while the amount of injected tracer remains finite. Any of these limits will correspond to a delta function input. [Pg.546]

The use of Equation (15.40) is limited to closed systems like that illustrated in Figure 15.10(a). Measurement problems arise whenever /), > 0 or Dgut > 0. See Figure 15.10(b) and suppose that an impulse is injected into the system at z = 0. If Din > 0, some of the tracer may enter the reactor, then diffuse backward up the inlet stream, and ultimately reenter. If Dgut > 0, some material leaving the reactor will diffuse back into the reactor to exit a second time. These molecules will be counted more than once by the tracer detection probes. The measured response function is not f t) but another function, g i), which has a larger mean ... [Pg.561]

Kainer R. A functional model of the rat kidney. J Math Biol 1979 7 57-94. Kassissia IG, Goresky CA, Rose CP, Schwab AJ, Simard A, Huet PM, Bach GG. Tracer oxygen distribution is barrier-limited in the cerebral microcirculation. Circ Res 1995 77 1201-11. [Pg.526]

Stable and radioactive tracers have been used extensively in catalysis to validate reaction networks, test for intermediates, confirm reaction orders, distinguish between intra- and inter-molecular mechanisms, establish rate limiting steps, docviment direct participation of surface atoms in fluid-solid reactions, etc. A unique feature of tracer studies is that Individual reaction steps can be followed in a complicated set of reactions without perturbing the chemical composition of the... [Pg.88]


See other pages where Tracer limitations is mentioned: [Pg.311]    [Pg.571]    [Pg.311]    [Pg.571]    [Pg.215]    [Pg.9]    [Pg.272]    [Pg.16]    [Pg.444]    [Pg.473]    [Pg.512]    [Pg.1013]    [Pg.35]    [Pg.500]    [Pg.1022]    [Pg.1319]    [Pg.59]    [Pg.100]    [Pg.86]    [Pg.562]    [Pg.88]    [Pg.38]    [Pg.212]    [Pg.215]    [Pg.216]    [Pg.179]    [Pg.612]    [Pg.637]    [Pg.651]    [Pg.986]    [Pg.27]    [Pg.31]    [Pg.317]    [Pg.484]    [Pg.25]    [Pg.160]   
See also in sourсe #XX -- [ Pg.232 ]




SEARCH



© 2024 chempedia.info