Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Test station

Bladder plate Rston Plastic plaLe Flow Fields [Pg.988]

The cell performance (polarization curve) strongly depends on the operating conditions, such as temperature, pressure, relative humidity (RH), gas flow rates, etc. Normally, the performance increases with increasing temperature, pressure, RH, and gas flow rate. [Pg.988]


Top left Complete testing station comprising testing unit,... [Pg.642]

A series of tests were performed at the AFC s National Reactor Testing Station in Idaho, starting in 1953. The reactor was situated outdoors, and was operated remotely. The core of the first version had fuel assembhes of aluminum and enriched uranium plates of the Materials Testing Reactor (MTR) type, installed in a water tank. One of the five control rods could be ejected downward and out of the core by spring action upon intermption of a magnet... [Pg.217]

The first experimental breeder reactor (EBR-1), which was the first reactor to generate electricity on a practical basis, went into operation in 1951 at the National Reactor Testing Station in Idaho. After the first reactor was damaged by a power excursion, EBR-11 was put into operation in 1961 (57). As of early 1995 it continued to operate very well. [Pg.221]

One was a water-moderated and water-cooled pressurized reactor the other was a Hquid-metal-cooled iatermediate neutron energy reactor. A land-based prototype submafine power plant called Mark I was built and tested at the National Reactor Testing Station. Argonne National Laboratory provided scientific data and Bettis Laboratory of Westinghouse Electric Corp. suppHed engineering expertise. [Pg.223]

The plastic plates and terminals are fitted into cast housings inside concrete columns or in built-up areas, in cable junction boxes installed at walls. Belowground test points should be installed in built-up areas only in exceptional circumstances. In this case watertight, flush-mounted test stations are installed under a street-level covering and can be kept dry only by the most careful construction. [Pg.277]

Select the location of cathodic-protection test stations. [Pg.212]

First Complete Test Station for Multiple-micro-reactor testing... [Pg.11]

Figure 1.7 Schematic outline of the constructional principle of the multiple-micro-reactor test station [2j. Figure 1.7 Schematic outline of the constructional principle of the multiple-micro-reactor test station [2j.
A micro reactor concept proposed by MIT and DuPont on the basis of electronic circuits is the most prominent among the examples listed for the hybrid approach [19,101]. The so-called turnkey multiple micro-reactor test station relies on the use of standard components originating from the semiconductor industry for microchemical processing, the construction being oriented at the concept of printed circuit boards. [Pg.64]

Jensen gives several examples for his present highly integrated chip systems [101], including a gas-phase reactor, a liquid-phase reactor, a catalyst-testing reactor, and a packed-bed multi-phase reactor. In addition, he provides the vision of a multiple micro-reactor test station (see Section 1.5.5.2). [Pg.65]

Shoebox-sized lab-on-a-chip laboratories personal dmg manufacture general advantages of micro flow Merck s production nitrations HTS parallel catalyst testing turnkey bench-scale test station standardization cube-like modules [210],... [Pg.86]

In preparation for the screen, a sufficient number of scoring sheets are filled in with the appropriate information. Then the cart employed as a mobile testing station is checked to ensure that all the necessary equipment (empty wire-bottom cage, blunt probe, penlight, 1/2 in. diameter steel rod, force transducer, ink pad, pad of blotting paper, ruler, and electronic probe thermometer) are on the cart and in forking order. Each animal is then evaluated by the following procedures. [Pg.748]

The position and angle of the test pieces to the sun (for both radiation and temperature) is important. A wide range of exposure methods and angles are available at most test stations. The more conventional and widely used are ... [Pg.53]

PEFC) stacks, components and entire systems, in off-grid, and grid-connected configurations, with a capacity of up to 100 kW electrical power output. The facility consists of an automated and computerised fuel cell test station, gas analysers, a multi-axial vibration system which is housed in a walk-in environmental chamber (for controlling temperatures, humidity, shocks and vibrations) and ancillary equipment. The data obtained are complementary to and validate fuel cell simulations and models with reference to operation modes, components and system characteristics 1 ... [Pg.14]

As briefly mentioned in Section 4.3.S.2, Atiyeh et al. [152] performed water balance measurements and calculations to determine the effect of using DLs with MPLs (on either or both cathode and anode sides). In their fuel cell test station, water collection systems were added in order to be able to collect and measure accurately the water leaving both anode and cathode sides of the fuel cell. Based on the operating conditions (e.g., pressures, temperatures, relative humidities, etc.) and the total amount of water accumulated at the outlets of the test station, water balance calculations were performed fo defermine the net water drag coefficient. Janssen and Overvelde [171] used this method to observe how different operating conditions and fuel cell maferials affected... [Pg.271]

Organic Branch, Chemistry Division, U.S. Naval Ordnance Test Station, China Lake, California. [Pg.15]

An improved electrochemical cell for in situ studies is presented in Figure 14.2. In this method a platinized Pt electrode located in the anode compartment serves as the reference electrode. This cell can be installed in a test station. Such a station can have facilities for temperature and pressure control, humidification of reactant gases (e.g., hydrogen and oxygen), gas flow rate measurement, and measurement of half- and... [Pg.240]

U.S. Naval Ordinance Test Station. 1940. China Lake, CA. [Pg.139]

Atmospheric corrosion is the most extended type of corrosion in the World. Over the years, several papers have been published in this subject however, most of the research has been made in non-tropical countries and under outdoor conditions. Results of outdoor and indoor corrosion rate and corrosion aggressivity in tropical corrosion test stations of Cuba and Mexico are reported. [Pg.61]

Table I. Simple regression of TOW-ISO data and time for Campeche PCGM coastal test station in a period of 2 years. Equation t = a + b TOW-ISO, r = correlation coefficient, r2 = percentage of variation explained by the independent variable, P = Statistical... Table I. Simple regression of TOW-ISO data and time for Campeche PCGM coastal test station in a period of 2 years. Equation t = a + b TOW-ISO, r = correlation coefficient, r2 = percentage of variation explained by the independent variable, P = Statistical...
A simple regression was made between time and TOW-ISO for the different test stations under heat trap conditions for a two year exposure time. The results were the following . Heat trap conditions[22] refer to the exposure of samples inside metallic boxes. In those conditions of partially closed metallic boxes, sun irradiation causes a significant increase in temperature and the maximum values of air temperature are obtained under these conditions. Some electro-electronic items are used under these conditions. [Pg.67]

Campeche PCGM coastal test station, Mexico ... [Pg.67]

CNIC urban rural test station, Cuba ... [Pg.68]

The results of a wide evaluation carried out on different exposure conditions in Cuba have already been published [3-4].The following Cuban corrosion test stations and conditions were considered ... [Pg.72]

Coastal test station under outdoor, sheltered and ventilated shed conditions... [Pg.72]

Figure 3. Changes in average, average maximum and minimum, maximum and minimum air temperature depending on exposure condition and type of atmosphere for test stations located in the western side of the Cuban Isle. Figure 3. Changes in average, average maximum and minimum, maximum and minimum air temperature depending on exposure condition and type of atmosphere for test stations located in the western side of the Cuban Isle.
Figure 5. Time of wetness at different exposure conditions and types of atmospheres calculated according to ISO 9223 for test stations of the western side of the Cuban Isle. Figure 5. Time of wetness at different exposure conditions and types of atmospheres calculated according to ISO 9223 for test stations of the western side of the Cuban Isle.

See other pages where Test station is mentioned: [Pg.214]    [Pg.223]    [Pg.15]    [Pg.361]    [Pg.998]    [Pg.213]    [Pg.69]    [Pg.11]    [Pg.106]    [Pg.257]    [Pg.612]    [Pg.241]    [Pg.51]    [Pg.67]    [Pg.68]    [Pg.77]   
See also in sourсe #XX -- [ Pg.193 , Pg.251 ]




SEARCH



Biological Warfare Test Station

Government Seed Testing Station

National Reactor Test Station

National Reactor Testing Station

National Reactor Testing Station Idaho)

Official Seed Testing Station

© 2024 chempedia.info