Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Structure analysis matrix

Figure 1.1 Structure analysis matrix that illustrates pharmaceutical analysis preferences for four specific sample types nontrace/pure nontrace/ mixture trace/pure and trace/mixture. (Courtesy of Milestone Development Services, Newtown, Pa., USA.)... Figure 1.1 Structure analysis matrix that illustrates pharmaceutical analysis preferences for four specific sample types nontrace/pure nontrace/ mixture trace/pure and trace/mixture. (Courtesy of Milestone Development Services, Newtown, Pa., USA.)...
If no laminae have failed, the load must be determined at which the first lamina fails (so-called first-ply failure), that is, violates the lamina failure criterion. In the process of this determination, the laminae stresses must be found as a function of the unknown magnitude of loads first in the laminate coordinates and then in the principal material directions. The proportions of load (i.e., the ratios of to Ny, to My,/ etc.) are, of course, specified at the beginning of the analysik The loaa parameter is increased until some individual lamina fails. The properties, of the failed lamina are then degraded in one of two ways (1) totally to zero if the fibers in the lamina fail or (2) to fiber-direction properties if the failure is by cracking parallel to the fibers (matrix failure). Actually, because of the matrix manipulations involved in the analysis, the failed lamina properties must not be zero, but rather effectively zero values in order to avoid a singular matrix that could not be inverted in the structural analysis problem. The laminate strains are calculated from the known load and the stiffnesses prior to failure of a lamina. The laminate deformations just after failure of a lamina are discussed later. [Pg.240]

In direct insertion techniques, reproducibility is the main obstacle in developing a reliable analytical technique. One of the many variables to take into account is sample shape. A compact sample with minimal surface area is ideal [64]. Direct mass-spectrometric characterisation in the direct insertion probe is not very quantitative, and, even under optimised conditions, mass discrimination in the analysis of polydisperse polymers and specific oligomer discrimination may occur. For nonvolatile additives that do not evaporate up to 350 °C, direct quantitative analysis by thermal desorption is not possible (e.g. Hostanox 03, MW 794). Good quantitation is also prevented by contamination of the ion source by pyrolysis products of the polymeric matrix. For polymer-based calibration standards, the homogeneity of the samples is of great importance. Hyphenated techniques such as LC-ESI-ToFMS and LC-MALDI-ToFMS have been developed for polymer analyses in which the reliable quantitative features of LC are combined with the identification power and structure analysis of MS. [Pg.409]

X-ray structural analysis. Suitable crystals of compound 14 were obtained from toluene/ether solutions. X-ray data were collected on a STOE-IPDS diffractometer using graphite monochromated Mo-Ka radiation. The structure was solved by direct methods (SHELXS-86)16 and refined by full-matrix-least-squares techniques against F2 (SHELXL-93).17 Crystal dimensions 0.3 0.2 0.1 mm, yellow-orange prisms, 3612 reflections measured, 3612 were independent of symmetry and 1624 were observed (I > 2ct(7)), R1 = 0.048, wR2 (all data) = 0.151, 295 parameters. [Pg.467]

Fig. 2.12. Relationship between sample domain and signal domain in element analysis (a) and structure analysis (b). The representation in the sample domains is shown in different forms, as a block diagram and a list in case of (a) and as constitution formula and structure matrix, respectively, in case (b)... Fig. 2.12. Relationship between sample domain and signal domain in element analysis (a) and structure analysis (b). The representation in the sample domains is shown in different forms, as a block diagram and a list in case of (a) and as constitution formula and structure matrix, respectively, in case (b)...
In an ideal case, the signal y A = f(zA), as shown in Fig. 3.6, is determined only by the analyte A (or the phenomenon of interest), namely both the position, zA = /(A), and intensity, yA = f(xA). But in real samples, matrix constituents are present which can principally interfere with the analyte signal. In structure analysis the same holds for the neighboring relationships (the environment of the species A of interest). Therefore, signal parameters are additionally influenced by the matrix (or the neighborhood , respectively), namely the species B,C,...,N, and follow then the complex relationships zA = /(A N), yA = /(xa xb,Xc,...,xN). Additionally, influencing factors a,b,...,m, background, y0, and noise (random deviations eA) may become relevant and have to be considered. [Pg.86]

Used in conjunction with infrared, NMR, UV and visible spectral data, mass spectrometry is an extremely valuable aid in the identification and structural analysis of organic compounds, and, independently, as a method of determining relative molecular mass (RMM). The analysis of mixtures can be accomplished by coupling the technique to GC (p. 114). This was formerly done by using sets of simultaneous equations and matrix calculations based on mass spectra of the pure components. It is well suited to gas... [Pg.439]

In this chapter the classification of measurements and unmeasured variables of chemical processes is discussed. After the statement of the problem, variable categorization is posed in terms of a structural analysis of the flowsheet. Then graph-and matrix-based strategies are briefly described and discussed. Illustratives examples of application are included. [Pg.45]

The second major contrast mechanism is extinction contrast. Here the distortion of the lattice arotmd a defect gives rise to a different scattering power from that of the surrotmding matrix. In all cases, it arises from a breakdown or change of the dynamical diffraction in the perfect ciystal. In classical structure analysis, the name extinction was used to describe the observation that the integrated intensity was less than that predicted by the kinematical theoiy. [Pg.182]

The electronic structure analysis given so far can be used to examine chemical reactivity features of this important subsystem. In real space, eqs. (7) and (13) can be adapted to study the change in amplitudes for the electronic states by diagonalizing the matrix equation over a finite number of diabatic states [11] ... [Pg.189]

The most recent developments in computational structural analysis are almost all based on the direct stiffness matrix method. As a result, piping stress computer programs such as SIMPLEX, ADLPIPE, NUPIPE, PIPESD, and CAESAR, to name a few, use the stiffness method. [Pg.63]

A. Ghali and A. M. Neville, Structural Analysis—A Unified Classical and Matrix Approach, 3rd ed., Chapman Hall, New York, 1990. [Pg.68]

C. S. Creaser, J. C. Reynolds, and D. J. Harvey, Structural analysis of oligosaccharides by atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap mass spectrometry, Rapid Commun. Mass Spectrom., 16 (2002) 176-194. [Pg.129]

B. Spengler, D. Kirsch, R. Kaufmann, and J. Lemoine, Structure analysis of branched oligosaccharides using post-source decay in matrix-assisted laser desorption ionization mass spectrometry, Org. Mass Spectrom., 29 (1994) 782-787. [Pg.135]

Mass spectrometry, especially in the form of fast atom bombardment, has become a potent tool in the elucidation of the structure of phospholipids. In this technique, the phospholipid sample in amounts in the range of 15-100 ng (or more), dissolved in chloroform-methanol (1 1, v/v), is mixed with a glycerol or thioglycerol matrix and placed on a sample mount in the spectrometer. A fast atom gun is then aimed, at a 90° angle, at the sample and the resulting ionized particles are directed to a mass analyzer unit. Under these conditions, most of the energy of the beam is limited to the surface of sample matrix. Consequently, the bulk of the sample is unaltered and can be recovered by solvent extraction. In the case of phospholipids, a mass ion, MH+, is produced also, some fragments are useful for structural analysis. A more... [Pg.58]

CNT nanocomposites morphological and structural analysis is often done by TEM but an extensive imaging is required then to ensure a representative view of the material. Moreover, carbon based fillers have very low TEM contrast when embedded in a polymer matrix. The application of microscopy techniques is very useful to control the status of CNTs at any time during the preparation process of CNT/polymer nanocomposites, and moreover, to gain insights on parameters important for a better understanding the performance of the final nanocomposite material based on CNTs. [Pg.69]

Lemoine, J., Chirat, F. and Domon, B. (1996) Structural analysis of derivatized oligosaccharides using post-source decay matrix-assisted laser desorption ionization mass spectrometry. J. Mass Spectrom., 31 (8), 908-12. [Pg.400]


See other pages where Structure analysis matrix is mentioned: [Pg.122]    [Pg.299]    [Pg.26]    [Pg.394]    [Pg.345]    [Pg.33]    [Pg.153]    [Pg.70]    [Pg.63]    [Pg.875]    [Pg.82]    [Pg.438]    [Pg.204]    [Pg.594]    [Pg.204]    [Pg.163]    [Pg.7]    [Pg.299]    [Pg.698]    [Pg.43]    [Pg.409]    [Pg.108]    [Pg.116]    [Pg.55]    [Pg.70]    [Pg.436]   
See also in sourсe #XX -- [ Pg.4 ]




SEARCH



Structure matrix

© 2024 chempedia.info