Stopped-flow method Applications

NMR spectroscopy finds a number of applications in chemical kinetics. One of these is its application as an analytical tool for slow reactions. In this method the integrated area of a reactant, intermediate, or product is determined intermittently as the reaction progresses. Such determinations are straightforward and will not concern us further, except to note that the use of an internal standard improves the accuracy. With flow mixing, one may examine even more rapid reactions. This is simply overflow application of the stopped-flow method. [Pg.261]

The broad and nearly universal applicability of the cinchonan carbamate CSPs for chiral acid separations is further corroborated by successful enantiomer separations of acidic solutes having axial and planar chirality, respectively. For example, Tobler et al. [124] could separate the enantiomers of atropisomeric axially chiral 2 -dodecyloxy-6-nitrobiphenyl-2-carboxylic acid on an C-9-(tert-butylcarbamoyl)quinine-based CSP in the PO mode with a-value of 1.8 and Rs of 9.1. This compound is stereolabile and hence at elevated temperatures the two enantiomers were interconverted during the separation process on-column revealing characteristic plateau regions between the separated enantiomer peaks. A stopped-flow method was utilized to determine the kinetic rate constants and apparent rotational energy barriers for the interconversion process in the presence of the CSP. Apparent activation energies (i.e., energy barriers for interconversion) were found to be 93.0 and 94.6 kJ mol for the (-)- and (-l-)-enantiomers, respectively. [Pg.84]

The stopped-flow method is more often used than any other technique for observing fast reactions with half-lives of a few milliseconds. Another attribute of this method is that small amounts of reactants are used. One must realize, however, that flow techniques are relaxation procedures that involve concentration jumps after mixing. Thus, the mixing or perturbation time determines the fastest possible rate that can be measured. Stopped-flow methods have been widely used to study organic and inorganic chemical reactions and to elucidate enzymatic processes in biochemistry (Robinson, 1975 1986). The application of stopped-flow methods to study reactions on soil constituents is very limited to date (Ikeda et ai, 1984a). [Pg.92]

Following the original rapid-flow experiments of Hartridge and Roughton, the introduction of the stopped-flow method, and the use of electronic techniques for rapid recording, rapid-reaction techniques have found wide application in chemistry and bio-... [Pg.53]

Conductance has achieved a great variety of industrial and research applications in a wide range of fields from simple conductance titrations to modern ion chromatographic detections. Kinetic measurements can also be made by using the stop-flow method or other methods. Experiments are fairly easy to carry out because of the availability of a variety of self-balancing bridges. [Pg.26]

The usefulness of a technique is not, of course, related solely to the maximum time resolution or observable rate constant other factors such as versatility, precision, convenience of operation and availability can all be important. The stopped-flow method, for instance, which is the most widely used of all, owes its popularity to its adaptability, speed and convenience, robustness, and wide availability it is suited not to the fastest reactions but to those with rate constants less than about 10 M s . Conversely, fluorescencequenching methods are applicable only to very fast reactions, for which however they are very powerful and flash techniques, uniquely, can follow changes down to 10 s. The availability of commercial equipment, and its cost, may also be important, especially where sophisticated electronic instrumentation is required. [Pg.11]

Recently, Hurwitz and Kustin have reinvestigated this exchange reaction using the same isotopic procedure and the 2-butanone separation method, in conjunction with a stopped flow apparatus. A rate coefficient of 2.3 x 10 l.mole . sec was obtained for the conditions, temperature 25 °C and ionic strength 0.1 M. Application of the Marcus theory to results obtained for the reaction... [Pg.122]

Atienza et al. [657] reviewed the applications of flow injection analysis coupled to spectrophotometry in the analysis of seawater. The method is based on the differing reaction rates of the metal complexes with 1,2-diaminocycl-ohexane-N, N, N, A/Metra-acetate at 25 °C. A slight excess of EDTA is added to the sample solution, the pH is adjusted to ensure complete formation of the complexes, and a large excess of 0.3 mM to 6 mM-Pb2+ in 0.5 M sodium acetate is then added. The rate of appearance of the Pbn-EDTA complex is followed spectrophotometrically, 3 to 6 stopped-flow reactions being run in succession. Because each of the alkaline-earth-metal complexes reacts at a different rate, variations of the time-scan indicates which ions are present. [Pg.236]

Many transition metal complexes have been considered as synzymes for superoxide anion dismutation and activity as SOD mimics. The stability and toxicity of any metal complex intended for pharmaceutical application is of paramount concern, and the complex must also be determined to be truly catalytic for superoxide ion dismutation. Because the catalytic activity of SOD1, for instance, is essentially diffusion-controlled with rates of 2 x 1 () M 1 s 1, fast analytic techniques must be used to directly measure the decay of superoxide anion in testing complexes as SOD mimics. One needs to distinguish between the uncatalyzed stoichiometric decay of the superoxide anion (second-order kinetic behavior) and true catalytic SOD dismutation (first-order behavior with [O ] [synzyme] and many turnovers of SOD mimic catalytic behavior). Indirect detection methods such as those in which a steady-state concentration of superoxide anion is generated from a xanthine/xanthine oxidase system will not measure catalytic synzyme behavior but instead will evaluate the potential SOD mimic as a stoichiometric superoxide scavenger. Two methodologies, stopped-flow kinetic analysis and pulse radiolysis, are fast methods that will measure SOD mimic catalytic behavior. These methods are briefly described in reference 11 and in Section 3.7.2 of Chapter 3. [Pg.270]

Applications of LC-NMR are still scarce but the technique will become more widely used. The main effort for efficient exploitation of LC-NMR needs to be made on the chromatographic side, where strategies involving efficient preconcentration, high loading, stop-flow, time slicing, or low flow procedures have to be developed. Microbore columns or capillary separation methods, such as capillary LC-NMR, CE-NMR, and CEC-NMR, will find increased application, one reason being that the low solvent consumption will allow the use of fully deuterated solvents. [Pg.31]

Applications of the bipolar pulse technique have demonstrated its utility in a variety of experiments, but it is particularly useful in monitoring reaction kinetics [18]. The technique has been shown to be useful on the stopped-flow time scale by the investigation of the dehydration of carbonic acid [20]. The study of this widely used text reaction demonstrates the accuracy and precision of the method. A sample data set from a single experiment is shown in Figure 8.16, and the excellent precision obtainable in such experiments is evident. The... [Pg.262]

The kinetic behavior of solvated electrons has been followed directly using flash radiolysis (44, 45, 58) or flash photolysis technique (62, 94, 107). The former method is more universally applicable owing to the high absorption coefficient of e soiv in a spectral region where most reactants contribute little to the overall optical density. Stopped-flow spectrophotometry has also been applied in the specific case of the eaq + H20 reaction (43), but it is not applicable to reactions where the e soiv half-life is below 0.1 msec. [Pg.63]

Stopped-Flow Instrumentation and Design 92 Application of Stopped-Flow Techniques to Soil Constituent Reactions 93 Electric Field Methods 95 Introduction 95... [Pg.61]

A recent book on physical chemistry,5 written by a scientist6 and aimed primarily at other scientists, contains substantial historical information on the beginnings of physical chemistry and on various topics, such as chemical spectroscopy, electrochemistry, chemical kinetics, colloid and surface chemistry, and quantum chemistry. The book also discusses more general topics, such as the development of the physical sciences and the role of scientific journals in scientific communication. The same author has written a brief account of the development of physical chemistry after 1937,7 emphasizing the application of quantum theory and the invention of new experimental methods stopped-flow techniques (1940), nuclear magnetic resonance... [Pg.135]

Frequently industrial hygiene analyses require the identification of unknown sample components. One of the most widely employed methods for this purpose is coupled gas chromatography/ mass spectrometry (GC/MS). With respect to interface with mass spectrometry, HPLC presently suffers a disadvantage in comparison to GC because instrumentation for routine application of HPLC/MS techniques is not available in many analytical chemistry laboratories (3). It is, however, anticipated that HPLC/MS systems will be more readily available in the future ( 5, 6, 1, 8). HPLC will then become an even more powerful analytical tool for use in occupational health chemistry. It is also important to note that conventional HPLC is presently adaptable to effective compound identification procedures other than direct mass spectrometry interface. These include relatively simple procedures for the recovery of sample components from column eluate as well as stop-flow techniques. Following recovery, a separated sample component may be subjected to, for example, direct probe mass spectrometry infra-red (IR), ultraviolet (UV), and visible spectrophotometry and fluorescence spectroscopy. The stopped flow technique may be used to obtain a fluorescence or a UV absorbance spectrum of a particular component as it elutes from the column. Such spectra can frequently be used to determine specific properties of the component for assistance in compound identification (9). [Pg.83]


See other pages where Stopped-flow method Applications is mentioned: [Pg.54]    [Pg.285]    [Pg.280]    [Pg.35]    [Pg.54]    [Pg.64]    [Pg.74]    [Pg.80]    [Pg.215]    [Pg.286]    [Pg.153]    [Pg.494]    [Pg.369]    [Pg.186]    [Pg.35]    [Pg.320]    [Pg.520]    [Pg.18]    [Pg.37]    [Pg.382]    [Pg.138]    [Pg.415]    [Pg.235]    [Pg.123]    [Pg.62]    [Pg.254]    [Pg.260]    [Pg.357]    [Pg.160]    [Pg.171]    [Pg.1915]    [Pg.6313]    [Pg.6325]    [Pg.6382]   