Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Rapid flow

Other properties of association colloids that have been studied include calorimetric measurements of the heat of micelle formation (about 6 kcal/mol for a nonionic species, see Ref. 188) and the effect of high pressure (which decreases the aggregation number [189], but may raise the CMC [190]). Fast relaxation methods (rapid flow mixing, pressure-jump, temperature-jump) tend to reveal two relaxation times t and f2, the interpretation of which has been subject to much disagreement—see Ref. 191. A fast process of fi - 1 msec may represent the rate of addition to or dissociation from a micelle of individual monomer units, and a slow process of ti < 100 msec may represent the rate of total dissociation of a micelle (192 see also Refs. 193-195). [Pg.483]

The set-up of Fig. 11, 41, 3 ensures the complete condensation of the steam when a rapid flow of steam is necessary for satisfactory results, and is useful in the distillation of large volumes of liquids of low vapour pressure, such as nitrobenzene. Thus the flask A containing the mixture may be of 3-litre capacity and B may be a 1-litre flask the latter is cooled by a stream of water, which is collected in a funnel and conducted to the sink. The receiver C must be of proportionate size all stoppers... [Pg.147]

The environmental sampling of waters and wastewaters provides a good illustration of many of the methods used to sample solutions. The chemical composition of surface waters, such as streams, rivers, lakes, estuaries, and oceans, is influenced by flow rate and depth. Rapidly flowing shallow streams and rivers, and shallow (<5 m) lakes are usually well mixed and show little stratification with... [Pg.193]

In pneumatic nebulizers, the relative velocity of gas and liquid first induces a reduction in pressure above the surface of the liquid (see the calculation in Figure 19.4). The reduction in pressure is sufficient to cause liquids to flow out of capillary tubes, in accord with Poiseuille s formula (Figure 19.5). As the relative velocity of a liquid and a gas increases — particularly if the mass of liquid is small — this partial vacuum and rapid flow cause the surface of the liquid to be broken into droplets. An aerosol is formed. [Pg.140]

Oxygen inhalators are used as a first-aid measure for a long Hst of emergencies, including heart attacks and suffocation, and as a result are carried routinely by rescue squads. Oxygen—helium mixtures have proved beneficial in asthmatic attacks, because these permit more rapid flow of gas into congested areas of the respiratory system. [Pg.482]

Electrification is the process of producing an electric charge on an object. If the charge is confined to the object it is said to be electrostatic. The term static electricity refers to accumulated, immobile, electrical charges in contrast to charges in rapid flow, which is the subject of electrodynamics. [Pg.286]

Toxicity. The toxicity of barium compounds depends on solubility (47—49). The free ion is readily absorbed from the lung and gastrointestinal tract. The mammalian intestinal mucosa is highly permeable to Ba " ions and is involved in the rapid flow of soluble barium salts into the blood. Barium is also deposited in the muscles where it remains for the first 30 h and then is slowly removed from the site (50). Very Httle is retained by the fiver, kidneys, or spleen and practically none by the brain, heart, and hair. [Pg.483]

The possible effects of fluid velocity on galvanic corrosion are sometimes overlooked. Fluid velocity can affect the apparent potential of metals in a given environment. Depending on the environment, a metal under the influence of relatively rapid flow may assume either a more noble or a more active character than that indicated by the galvanic series. Occasionally, this shift in potential may result in galvanic corrosion that would not occur under stagnant or low-flow conditions. [Pg.362]

Formation of vapor bubbles in rapidly flowing or turbulent water causing risk of pumping failure and erosion and/or corrosion. Due to an increase in velocity at the pump head resulting in a localized pressure reduction and the subsequent collapse of the vapor into voids or cavities. Where FW temperatures are high (over perhaps 195-205 °F) the pump velocity can reduce FW vapor pressure below that corresponding to the temperature of the liquid and cavitation can occur accompanied by some noise. Warning of severe pump cavitation is often indicated by a heavy noise. [Pg.722]

Three different types of turbulent flow may be obtained in open channels. They are tranquil flow, rapid flow, and critical flow. In tranquil flow the velocity is less than that at which some disturbance, such as a surge wave, will be transmitted, and the flow is influenced by conditions at both the upstream and the downstream end of the channel. In rapid flow, the velocity of the fluid is greater than the velocity of a surge wave and the... [Pg.95]

Similarly it may be shown that, at the critical conditions, the flowrate is a maximum for a given value of the specific energy J. At the critical velocity, (ir/gD) is equal to unity. This dimensionless group is known as the Froude number Fr. For velocities greater than the critical velocity Fr is greater than unity, and vice versa. It may be shown that the velocity with which a small disturbance is transmitted through a liquid in an open channel is equal to the critical velocity, and hence the Froude number is the criterion by which the type of flow, tranquil or rapid, is determined. Tranquil flow occurs when Fr is less than unity and rapid flow when Fr is greater than unity. [Pg.100]

Surface runoff. Hydrologists have identified two processes for generating surface runoff over land. The first, saturated overland flow (SOF), is generated when precipitation (or snowmelt) occurs over a saturated soil since water has nowhere to infiltrate, it then runs off over land. SOF typically occurs only in humid environments or where the water table rises to intersect with a stream. Horton overland flow (HOF or infiltration-limited overland flow) occurs when precipitation intensity exceeds the infiltration capacity of the soil in a non-saturated environment. In this case, only the excess precipitation (that exceeding the infiltration capacity) runs off over the surface. Both types of overland runoff generate relatively rapid flows that constitute the surface water contribution to the hydrograph (Fig. 6-6). [Pg.118]

Haskell CA, Cleary MD, Charo IF. Molecular uncoupling of fractalkine-mediated cell adhesion and signal transduction. Rapid flow arrest of CX3CR1-expressing cells is independent of G-protein activation. J Biol Chem 1999 274(15) 10053-10058. [Pg.256]

Electrostatic repulsion of the anionic carboxylate groups elongates the polymer chain of partially hydrolyzed polyacrylamides increasing the hydrodynamic volume and solution viscosity. The extensional viscosity is responsible for increased resistance to flow at rapid flow rates in high permeability zones (313). The screen factor is primarily a measure of the extensional (elonga-tional) viscosity (314). The solution properties of polyacrylamides have been studied as a function of NaCl concentra-tion and the parameters of the Mark-Houwink-Sakaruda equation calculated... [Pg.36]

Longitudinal diffusion will become more serious the longer the solute species spend in the column, so this effect, unlike flow dispersion is reduced by using a rapid flow rate of mobile phase. [Pg.37]

Previously, intense beams of metal clusters could only be produced for the most volatile metals. The limitation arose from significant materials problems involved in the construction of high temperature ovens. The development of a source that utilizes laser vaporization and subsequent condensation in a rapidly flowing gas eliminated the materials problem and has enabled just about any material to be studi ed(la,8). [Pg.48]

Method. The laser vaporization source eliminates the material constraints inherent in conventional oven sources. This is accomplished by localizing the heating to a very small area at the surface of the sample and by entraining the vapor produced in a rapid flow of high pressure gas. [Pg.48]


See other pages where Rapid flow is mentioned: [Pg.188]    [Pg.90]    [Pg.643]    [Pg.57]    [Pg.491]    [Pg.478]    [Pg.410]    [Pg.1855]    [Pg.53]    [Pg.1094]    [Pg.368]    [Pg.257]    [Pg.373]    [Pg.1002]    [Pg.98]    [Pg.896]    [Pg.889]    [Pg.54]    [Pg.53]    [Pg.253]    [Pg.513]    [Pg.402]    [Pg.914]    [Pg.518]    [Pg.522]    [Pg.34]    [Pg.34]    [Pg.527]    [Pg.7]    [Pg.26]    [Pg.210]    [Pg.210]    [Pg.164]   
See also in sourсe #XX -- [ Pg.100 ]

See also in sourсe #XX -- [ Pg.260 ]




SEARCH



Channel Flow with Soluble or Rapidly Reacting Walls

Channel flow with rapidly reacting walls

Continuous-flow method rapid-mixing

Cytochrome, rapid flow techniques

Enzyme reactions rapid flow techniques

Laser rapid-flow method

Radioactive tracer movement in cell suspension studied with rapid flow technique

Rapid flow reactors

Rapid flow technique

Rapid mix flow cytometry

Rapid mixing continuous flow device

Rapid mixing methods stopped flow

Rapid reaction by flow technique

Rapid scanning spectroscopy stopped flow

Rapid scanning stopped-flow

Rapid scanning stopped-flow commercial availability

Rapid scanning stopped-flow design

Rapid scanning stopped-flow detectors

Rapid scanning stopped-flow enzyme concentration

Rapid scanning stopped-flow instrumentation

Rapid scanning stopped-flow scan rates

Rapid scanning stopped-flow studies

Rapid-scanning stopped-flow UV-visible

Rapid-scanning stopped-flow system,

Stopped flow rapid scan

Stopped-flow kinetics, rapid scanning techniques

Stopped-flow rapid scan spectra

Timescales rapid flow techniques

© 2024 chempedia.info