Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Steady Streaming

The principal dilTerence from liquid-state NMR is that the interactions which are averaged by molecular motion on the NMR timescale in liquids lead, because of their anisotropic nature, to much wider lines in solids. Extra infonnation is, in principle, available but is often masked by the lower resolution. Thus, many of the teclmiques developed for liquid-state NMR are not currently feasible in the solid state. Furthemiore, the increased linewidth and the methods used to achieve high resolution put more demands on the spectrometer. Nevertheless, the field of solid-state NMR is advancing rapidly, with a steady stream of new experiments forthcoming. [Pg.1466]

Phosphorus pentachloride is prepared by the action of chlorine on phosphorus trichloride. To push the equilibrium over to the right, the temperature must be kept low and excess chlorine must be present. Hence the liquid phosphorus trichloride is run dropwise into a flask cooled in ice through which a steady stream of dry chlorine is passed the solid pentachloride deposits at the bottom of the flask. [Pg.251]

Alexandra Seabrook, Pauline Gillet and Julie JCnight at Pearson Education provided the foundation of the publishing team, coping with a steady stream of questions and keeping everyone to schedule. Especial thanks are due to Julie, who did a splendid job as editor. [Pg.17]

The application of density functional theory to isolated, organic molecules is still in relative infancy compared with the use of Hartree-Fock methods. There continues to be a steady stream of publications designed to assess the performance of the various approaches to DFT. As we have discussed there is a plethora of ways in which density functional theory can be implemented with different functional forms for the basis set (Gaussians, Slater type orbitals, or numerical), different expressions for the exchange and correlation contributions within the local density approximation, different expressions for the gradient corrections and different ways to solve the Kohn-Sham equations to achieve self-consistency. This contrasts with the situation for Hartree-Fock calculations, wlrich mostly use one of a series of tried and tested Gaussian basis sets and where there is a substantial body of literature to help choose the most appropriate method for incorporating post-Hartree-Fock methods, should that be desired. [Pg.157]

Aminopyridine. In a 1 litre three-neoked flask, equipped with a sealed mechanical stirrer, reflux condenser, thermometer and inlet tube for nitrogen, place 300 ml. of dry toluene (1) aud 75 g. of fine granular sodamide (2) bubble a steady stream of nitrogen thi ough the toluene. Stir the mixtiue vigorously and heat the flask in an oil bath until the internal temperatime is 110° (the bath temperatime required is approximately 130°). Add 100 g. of pure dry pyridine (compare Section 11,47,22)... [Pg.1007]

Winning the Nobel Prize inevitably brings with it, besides a brief period of wider publicity (which in America evaporates particularly fast), a steady stream of invitations, varied honors and recognitions, as well as more general public involvement. Professors and scientists in American life are usually not exactly at the top of the social ladder, nor are they used to much recognition. Personally, I rather like this, because it helps not to attach overgrown significance to one s importance, keeps one humanized, and, most important, allows one to stay centered without much distraction from one s work. It was, therefore,... [Pg.185]

A. 2-(Trimethtjlsiloxymethyl)allyltvimethylBilane. An oven-dried (Note 1) 2-L, three-necked, round-bottomed flask is equipped with an air-tight mechanical stirrer (Note 2), a 500-mL pressure-equalizing dropping funnel (Note 3), and a reflux condenser. The top of the condenser is connected to a three-way stopcock with one branch connected to a nitrogen source and the other to a variable pressure oil pump with a dry-ice trap (Note 4). The apparatus is flamed dry under a steady stream of nitrogen. The flask is... [Pg.58]

Because of their great versatility there continues to be a steady stream of developments of polymers made by reaction of isocyanates. In addition to the materials discussed in this chapter there are, to name but three, the polyureas, the polyoxazolidinones and polybenzoxazinediones. [Pg.808]

The first detailed book to describe the practice and theory of stereology was assembled by two Americans, DeHoff and Rhines (1968) both these men were famous practitioners in their day. There has been a steady stream of books since then a fine, concise and very clear overview is that by Exner (1996). In the last few years, a specialised form of microstructural analysis, entirely dependent on computerised image analysis, has emerged - fractal analysis, a form of measurement of roughness in two or three dimensions. Most of the voluminous literature of fractals, initiated by a mathematician, Benoit Mandelbrot at IBM, is irrelevant to materials science, but there is a sub-parepisteme of fractal analysis which relates the fractal dimension to fracture toughness one example of this has been analysed, together with an explanation of the meaning of fractal dimension , by Cahn (1989). [Pg.204]

To a stirred suspension of 6-aminopenicillanic acid (540 g) in dry alcohol-free chloroform (3.75 liters) was added dry triethylamine (697 ml), and the mixture stirred for 10 minutes at room temperature. It was then cooled in a bath of crushed Ice while a solution of 2,6-dimethoxybenzoyl chloride (500 g) in dry alcohol-free chloroform (3.75 liters) was added in a steady stream over 20 minutes. When all the acid chloride had been added the cooling bath was removed and the mixture stirred for 1 hour at room temperature. The mixture was stirred vigorously and sufficient dilute hydrochloride acid (2.3 liters of 0.87 N) was added to give an aqueous layer of pH 2.5. The mixture was filtered, the layers separated, and only the chloroform layer was retained. [Pg.976]

The acid chloride obtained as described above was dissolved in dry acetone (10 ml) and added in a steady stream to a stirred solution of 6-aminopenicillanic acid (1.08 g, 5 mmol) in a mixture of N sodium bicarbonate (15 ml) and acetone (5 ml). After the initial reaction the reaction mixture was stirred at room temperature for 45 minutes, then washed with ether (3 X 25 ml). Acidification of the aqueous solution with N hydrochloric acid (11 ml) to pH 2 and extraction with ether (3 x 15 ml) gave an ethereal extract which was decolorized with a mixture of activated charcoal and magnesium sulfate for 5 minutes. [Pg.1482]

The reaction mixture is then stirred very vigorously and boiled at such a rate that the nitrobenzene condenses in the upper third of the air-cooled reflux condenser and flows back in an almost steady stream. The water formed in the reaction passes over, together with a small amount of nitrobenzene and iodobenzene, and is condensed by the water-cooled condenser. This distillate is freed of water by shaking with a small quantity of sodium sulfate and returned at intervals through the separatory funnel to the reaction flask. Heating is continued for about twenty-four hours or until the reaction is complete, as is evidenced by the non-evolution of water (Note 5). [Pg.116]

Throughout the irradiation a steady stream of argon was bubbled through the photolysate which was maintained at 20 C. Excess MeOH was removed under reduced pressure and the residue separated by column chromatography (neutral alumina). [Pg.128]

As a consequence, good, safe, steam-sampling points are required, and automatic, real-time continuous analyzer systems for monitoring of steam and condensate quality are very useful. These requirements usually are not a problem in larger power and process HP boiler plants. Here, each facility tends to have a unique combination of operating conditions and waterside chemistry circumstances that necessitate the provision of a steady stream of reliable operational data, and this can be obtained realistically only from continuous, real-time analysis. [Pg.600]

A fiber-diffraction pattern is recorded on a flat-film camera in which the fiber-to-photographic film distance is typically in the range of 3 to 4 cm. During exposure to X-rays, the specimen chamber is continuously flushed with a slow and steady stream of helium gas that has been bubbled through a saturated salt solution so that (a) the fiber is maintained at a constant desired r.h. and (b) fogging of the photographic film from air scattering is reduced. [Pg.314]

Example 14.2 Suppose the rabbits and lynx of Section 2.5.4 become migratory. Model their behavior given a steady stream of rabbits and lynx entering a grassy plain. Ignore the depletion of grass. [Pg.520]

The aurora borealis, a spectacular atmospheric light show shown in Figure 7-25. originates in the thermosphere. In addition to electromagnetic radiation, the sun emits a steady stream of protons and electrons. The Earth s magnetic field deflects most of these particles, but some reach the thermosphere above the north and south poles of the... [Pg.481]


See other pages where Steady Streaming is mentioned: [Pg.198]    [Pg.1910]    [Pg.29]    [Pg.33]    [Pg.166]    [Pg.186]    [Pg.495]    [Pg.114]    [Pg.182]    [Pg.185]    [Pg.359]    [Pg.140]    [Pg.150]    [Pg.449]    [Pg.451]    [Pg.323]    [Pg.53]    [Pg.16]    [Pg.73]    [Pg.541]    [Pg.65]    [Pg.8]    [Pg.436]    [Pg.245]    [Pg.63]    [Pg.155]    [Pg.143]    [Pg.24]    [Pg.184]    [Pg.563]    [Pg.569]    [Pg.114]    [Pg.182]    [Pg.185]   
See also in sourсe #XX -- [ Pg.1889 ]




SEARCH



Process simulation—steady state stream variables

© 2024 chempedia.info