Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Steady response

The electrode gave a steady-state current when the electrode potential was maintained at +0.35 V vs. Ag/AgCl in 0.1 M phosphate buffer. Addition of ethanol to the buffer solution resulted in an increase in the anodic current, which was attributed to the oxidation of membrane-bound NADH. A steady response was obtained within 40 sec. The increase in the anodic current was linearly correlated with the concentration of ethanol. [Pg.352]

The paper outlines a general procedure for predicting the dynamic response, including resonance, of hyperbolic cooling towers to turbulent winds. Pressure spectra on the tower surface were measured in a boundary layer wind tunnel. Application to full-scale tower is examined. It is concluded that while the quasi-steady response increases with the wind velocity squared, the resonant response increases faster than wind velocity cubed. 10 refs, cited. [Pg.292]

Optical (400 nm) Cross-linking with BSA md GA in a Byodine nylon membrane 10 pM paraoxon and parathion 10 min steady response >10 days [270]... [Pg.118]

Contrary to conventional practice, it is not necessary to wait tmtil the steady response of the detector indicates that the eluate concentration is the same as the concentration in the stream of mobile phase pumped into the column to return to a pure mobile phase stream. In fact, a wide rectangular injection is usually sufficient, provided that a concentration plateau is eluted at the column exit. Admittedly, in such an implementation of the method, it becomes difficult to decide whether it is FACP or ECP (see next section) but this is irrelevant. If the width of the rectangular pulse is kept reasonably narrow, the amount of sample needed is comparable to that required in ECP for the determination of the isotherm in the same concentration range. [Pg.125]

Equilibrium data can be determined from SPR data that have reached steady response levels during the association phase (Eq. 1) or can be calculated from the ratio of the association and dissociation constants (Eq. 2) determined from kinetic analysis ... [Pg.159]

FIGURE 4 Observed MSU temperature, shown as dashed line, for channel 4 (top) for the period 1979-1997 and the equivalent for the simulations with Mt. Pinatubo and stratospheric ozone. The mean value obtained from the six realizations is denoted by the solid line, whereas the shaded area represents this value plus and minus one standard deviation of the individual simulations, respectively. The same for channel 2LT (bottom). Note the steady response in the stratosphere and the large variability in the lower troposphere, (from Bengtsson et al, 1999). [Pg.19]

The dashed curves with the larger peak currents in Figure IB were obtained during the first voltammetric scan from 0.2 V with the cobalt center of the incorporated porphyrin in its oxidized state (enhanced cathodic peak for reduction of RuiNHale ) or its reduced state (enhanced anodic peak for oxidation of Os(bpy)3 ). The solid curves show the steady responses obtained in the absence of incorporated porphyrin or when the voltammetric scans were restricted to the range between 0.2 and —0.5 V or between 0.2 and 0.8 V so that the cobalt center remained in its reduced or oxidized state, respectively. The areas between the dashed and solid curves in Firare IB were used to measure the quantities of CoP(pyH)4 incorporated in me Nafion coatings. [Pg.383]

Collected drained volume values, cell characteristics and soil mass were used to mathematically obtain cumulative electroosmotic flow (mL cmr min i Kg"i), results are shown in Figure 4. From the plot can be established that effectively catalytic activity of TiCb allows for getting higher electroosmotic flow. As it can be observed in three hours the RVC-Xi02 anode (II) reached steady response, while the bare RVC anode (I) provides a much lower electroosmotic flow which seems to smoothly reach steady response at similar times, but after 10 hours, a new perturbation takes place and it goes to a transient response, the last taking place at an slower rate in respect to the initial one. [Pg.227]

The amplitude of the response, x 2ca), is given by the steady-state solution of equation B1.5.10 as... [Pg.1269]

The scan rate, u = EIAt, plays a very important role in sweep voltannnetry as it defines the time scale of the experiment and is typically in the range 5 mV s to 100 V s for nonnal macroelectrodes, although sweep rates of 10 V s are possible with microelectrodes (see later). The short time scales in which the experiments are carried out are the cause for the prevalence of non-steady-state diflfiision and the peak-shaped response. Wlien the scan rate is slow enough to maintain steady-state diflfiision, the concentration profiles with time are linear within the Nemst diflfiision layer which is fixed by natural convection, and the current-potential response reaches a plateau steady-state current. On reducing the time scale, the diflfiision layer caimot relax to its equilibrium state, the diffusion layer is thiimer and hence the currents in the non-steady-state will be higher. [Pg.1927]

Similarly to the response at hydrodynamic electrodes, linear and cyclic potential sweeps for simple electrode reactions will yield steady-state voltammograms with forward and reverse scans retracing one another, provided the scan rate is slow enough to maintain the steady state [28, 35, 36, 37 and 38]. The limiting current will be detemiined by the slowest step in the overall process, but if the kinetics are fast, then the current will be under diffusion control and hence obey the above equation for a disc. The slope of the wave in the absence of IR drop will, once again, depend on the degree of reversibility of the electrode process. [Pg.1940]

The effects of ultrasound-enlianced mass transport have been investigated by several authors [73, 74, 75 and 76]. Empirically, it was found that, in the presence of ultrasound, the limiting current for a simple reversible electrode reaction exhibits quasi-steady-state characteristics with intensities considerably higher in magnitude compared to the peak current of the response obtained under silent conditions. The current density can be... [Pg.1942]

The periodic shedding produces lateral forces of the same period on the cylinder. Should the cylinder be weakly supported and have a natural frequency close to the shedding frequency, it oscillates strongly in concert with the vortex street. Such behavior is responsible for the singing of power lines, the oscillation of tall smokestacks, and, most spectacularly, for the coUapse in 1940 of the newly built Tacoma Narrows suspension bridge, in Washington state, under the influence of a steady 65 km/h wind. [Pg.91]

Dyna.mic Viscometer. A dynamic viscometer is a special type of rotational viscometer used for characterising viscoelastic fluids. It measures elastic as weU as viscous behavior by determining the response to both steady-state and oscillatory shear. The geometry may be cone—plate, parallel plates, or concentric cylinders parallel plates have several advantages, as noted above. [Pg.187]

However, it is not practical to set the gas temperature in steady state without equally setting the temperature of the surface and bulk phases hounding the gas. Consideration of the response of the system as a vacuum environment can then provide a sufftciendy precise prediction of the pressure P and the surface coverage 9 at temperature Tfor molecules of a known species in a known state on a known surface. For example, an isotherm is estabhshed between the surface of the condensed and the gaseous phases, depending, eg, on the heat of desorption. For submonolayer coverage on a... [Pg.366]

Oxygen Transport. The most widely used methods for measuring oxygen transport are based upon the Ox-Tran instmment (Modem Controls, Inc.). Several models exist, but they all work on the same principle. The most common apphcation is to measure the permeabihty of a film sample. Typically, oxygen is introduced on one side of the film, and nitrogen gas sweeps the other side of the film to a coulometric detector. The detector measures the rate that oxygen comes through the film. The detector response at steady state can easily be converted to At (eq. 1). Simple... [Pg.499]

Water Transport. Two methods of measuring water-vapor transmission rates (WVTR) ate commonly used. The newer method uses a Permatran-W (Modem Controls, Inc.). In this method a film sample is clamped over a saturated salt solution, which generates the desired humidity. Dry air sweeps past the other side of the film and past an infrared detector, which measures the water concentration in the gas. For a caUbrated flow rate of air, the rate of water addition can be calculated from the observed concentration in the sweep gas. From the steady-state rate, the WVTR can be calculated. In principle, the diffusion coefficient could be deterrnined by the method outlined in the previous section. However, only the steady-state region of the response is serviceable. Many different salt solutions can be used to make measurements at selected humidity differences however, in practice,... [Pg.500]

Mathematically speaking, a process simulation model consists of a set of variables (stream flows, stream conditions and compositions, conditions of process equipment, etc) that can be equalities and inequalities. Simulation of steady-state processes assume that the values of all the variables are independent of time a mathematical model results in a set of algebraic equations. If, on the other hand, many of the variables were to be time dependent (m the case of simulation of batch processes, shutdowns and startups of plants, dynamic response to disturbances in a plant, etc), then the mathematical model would consist of a set of differential equations or a mixed set of differential and algebraic equations. [Pg.80]


See other pages where Steady response is mentioned: [Pg.272]    [Pg.211]    [Pg.118]    [Pg.100]    [Pg.296]    [Pg.140]    [Pg.310]    [Pg.102]    [Pg.87]    [Pg.264]    [Pg.73]    [Pg.272]    [Pg.211]    [Pg.118]    [Pg.100]    [Pg.296]    [Pg.140]    [Pg.310]    [Pg.102]    [Pg.87]    [Pg.264]    [Pg.73]    [Pg.21]    [Pg.706]    [Pg.1106]    [Pg.1115]    [Pg.1591]    [Pg.1607]    [Pg.1930]    [Pg.1933]    [Pg.1939]    [Pg.1940]    [Pg.2949]    [Pg.50]    [Pg.197]    [Pg.261]    [Pg.261]    [Pg.65]    [Pg.245]    [Pg.510]    [Pg.499]    [Pg.501]    [Pg.313]   
See also in sourсe #XX -- [ Pg.253 ]




SEARCH



© 2024 chempedia.info