Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Stationary selection

Final state analysis is where dynamical methods of evolving states meet the concepts of stationary states. By their definition, final states are relatively long lived. Therefore experiment often selects a single stationary state or a statistical mixture of stationary states. Since END evolution includes the possibility of electronic excitations, we analyze reaction products in terms of rovibronic states. [Pg.245]

To accomplish any separation of two cations (or two anions) of the same net charge, the stationary phase must show a preference for one more than the other. No variation in the eluant concentration will improve the separation. However, if the exchange involves ions of different net charges, the separation factor does depend on the eluant concentration. The more dilute the counterion concentration in the eluant, the more selective the exchange becomes for polyvalent ions. [Pg.1114]

From equation 12.1 it is clear that resolution may be improved either by increasing Afr or by decreasing wa or w-q (Figure 12.9). We can increase Afr by enhancing the interaction of the solutes with the column or by increasing the column s selectivity for one of the solutes. Peak width is a kinetic effect associated with the solute s movement within and between the mobile phase and stationary phase. The effect is governed by several factors that are collectively called column efficiency. Each of these factors is considered in more detail in the following sections. [Pg.550]

The main criteria for selecting a stationary phase are that it should be chemically inert, thermally stable, of low volatility, and of an appropriate polarity for the solutes being separated. Although hundreds of stationary phases have been developed, many of which are commercially available, the majority of GLC separations are accomplished with perhaps five to ten common stationary phases. Several of... [Pg.565]

A few GLC stationary phases rely on chemical selectivity. The most notable are stationary phases containing chiral functional groups, which can be used for separating enantiomers. ... [Pg.567]

The stationary phase in LC is a fine granular solid such as silica gel. It can be used as such (mainly for nonpolar compounds), or the granules can be modified by a surface-bonded coating that changes (reverses) the polarity of the gel. A very small selection of stationary phases is listed in Table 35.2. [Pg.249]

Limitations with the chiral selectivity of the native cyclodextrins fostered the development of various functionalized cyclodextrin-based chiral stationary phases, including acetylated (82,83), sulfated (84), 2-hydroxypropyl (85), 3,5-dimethylphenylcarbamoylated (86) and... [Pg.65]

Localized corrosion, which occurs when the anodic sites remain stationary, is a more serious industrial problem. Forms of localized corrosion include pitting, selective leaching (eg, dezincification), galvanic corrosion, crevice or underdeposit corrosion, intergranular corrosion, stress corrosion cracking, and microbiologicaHy influenced corrosion. Another form of corrosion, which caimot be accurately categorized as either uniform or localized, is erosion corrosion. [Pg.266]

The case is the largest portion of the container. The case is divided into compartments which hold the cell elements. The cores normally have a mud-rest area used to collect shed soHds from the battery plates and supply support to the element. Typical materials of constmction for the battery container are polypropylene, polycarbonate, SAN, ABS, and to a much lesser extent, hard mbber. The material used in fabrication depends on the battery s appHcation. Typical material selections include a polypropylene—ethylene copolymer for SLI batteries polystyrene for stationary batteries polycarbonate for large, single ceU standby power batteries and ABS for certain sealed lead—acid batteries. [Pg.578]

The Diacel columns can be used for the separation of a wide variety of compounds, including aromatic hydrocarbons having hydroxyl groups, carbonyls and sulfoxides, barbiturates, and P-blockers (35,36). There are presendy nine different cellulose derivative-based columns produced by Diacel Chemical Industries. The different columns each demonstrate unique selectivities so that a choice of stationary phases is available to accomplish a separation. [Pg.100]

A number of analytical methods have been developed for the determination of chlorotoluene mixtures by gas chromatography. These are used for determinations in environments such as air near industry (62) and soil (63). Liquid crystal stationary columns are more effective in separating m- and chlorotoluene than conventional columns (64). Prepacked columns are commercially available. ZeoHtes have been examined extensively as a means to separate chlorotoluene mixtures (see Molecularsieves). For example, a Y-type 2eohte containing sodium and copper has been used to separate y -chlorotoluene from its isomers by selective absorption (65). The presence of ben2ylic impurities in chlorotoluenes is determined by standard methods for hydroly2able chlorine. Proton (66) and carbon-13 chemical shifts, characteristic in absorption bands, and principal mass spectral peaks are available along with sources of reference spectra (67). [Pg.54]

Several hundred types of Hquid phases are commercially available. These have been used individually or in combination with other Hquid phases, inorganic salts, acids, or bases. The selection of stationary phases for a particular appHcation is beyond the scope of this article, however, it is one of the most important chromatographic tasks. Stationary phase selection is discussed at length in books, journal articles, and catalogs from vendors. See General References for examples. [Pg.106]

Affinity Chromatography. This technique involves the use of a bioselective stationary phase placed in contact with the material to be purified, the ligate. Because of its rather selective interaction, sometimes called a lock-and-key mechanism, this method is more selective than other lc systems based on differential solubiHty. Affinity chromatography is sometimes called bioselective adsorption. [Pg.110]


See other pages where Stationary selection is mentioned: [Pg.161]    [Pg.300]    [Pg.161]    [Pg.300]    [Pg.377]    [Pg.156]    [Pg.1287]    [Pg.558]    [Pg.565]    [Pg.566]    [Pg.566]    [Pg.580]    [Pg.582]    [Pg.609]    [Pg.610]    [Pg.610]    [Pg.48]    [Pg.49]    [Pg.49]    [Pg.53]    [Pg.57]    [Pg.57]    [Pg.61]    [Pg.62]    [Pg.63]    [Pg.64]    [Pg.66]    [Pg.68]    [Pg.321]    [Pg.111]    [Pg.33]    [Pg.72]    [Pg.9]    [Pg.98]    [Pg.55]    [Pg.55]    [Pg.104]    [Pg.105]    [Pg.108]    [Pg.110]   
See also in sourсe #XX -- [ Pg.611 ]




SEARCH



Bonded stationary phases shape selection

Chemically selective stationary phases

Chemically selective stationary phases compounds

Criteria for the Selection of Stationary Phases in TLC

Enantiomeric selection stationary phase preparation

HPLC (high performance liquid stationary phase, selection

Preparation, Testing, and Selectivity of Stationary Phase Materials

Selecting a Stationary Phase for an Application

Selection of Stationary Phases

Selection of the Stationary Phase Some Help from an

Selection of the Stationary Phase and Method

Selection, stationary-phase chemical bonding

Selection, stationary-phase polyethylene glycol phases

Selection, stationary-phase polysiloxane phases

Selectivity of Stationary Phase Materials

Selectivity of liquid stationary phases

Shape selectivity stationary-phase chemistry

Stationary phase buffer selection

Stationary phase column selectivity

Stationary phase selection

Stationary phase selections, HPLC development

Stationary phase selectivity parameter

Stationary phases selectivity

Stationary-phase selection for capillary gas chromatography

Stationary-phase selectivity, change

© 2024 chempedia.info