Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Stationary phases protein based

There is a wide variety of commercially available chiral stationary phases and mobile phase additives.32 34 Preparative scale separations have been performed on the gram scale.32 Many stationary phases are based on chiral polymers such as cellulose or methacrylate, proteins such as human serum albumin or acid glycoprotein, Pirkle-type phases (often based on amino acids), or cyclodextrins. A typical application of a Pirkle phase column was the use of a N-(3,5-dinitrobenzyl)-a-amino phosphonate to synthesize several functionalized chiral stationary phases to separate enantiomers of... [Pg.12]

Protein Based Stationary Phases The Pirkle Type Stationary Phases Coated Cellulose and Amylose Derivatives Macrocyclic Glycopeptide Stationary Phases Cyclodextrin Based Chiral Stationary Phases Synopsis References Chapter 9... [Pg.546]

Reversed-phase chromatography is a separation method based on the hydrophobicity of the protein. In RPC, the hydrophobic stationary phase is based on silica gel or a synthetic polymer. In recent years, instead of bulk materials for column packing, polymer- or silica gel-based monolithic stationary phases have also been used [43]. [Pg.161]

According to a recent publication, the separation of protein and plasmid DNA as well as that of DNA and lipopolysaccharides is possible by displacement chromatography. Linear polyacrylic acid (Os-type, Mw 5100 g/mol) was successfully used as displacer. A particularity was the fact that conventional stationary phase materials based on porous anion exchanger or... [Pg.71]

The analysis demonstrates the elegant use of a very specific type of column packing. As a result, there is no sample preparation, so after the serum has been filtered or centrifuged, which is a precautionary measure to protect the apparatus, 10 p.1 of serum is injected directly on to the column. The separation obtained is shown in figure 13. The stationary phase, as described by Supelco, was a silica based material with a polymeric surface containing dispersive areas surrounded by a polar network. Small molecules can penetrate the polar network and interact with the dispersive areas and be retained, whereas the larger molecules, such as proteins, cannot reach the interactive surface and are thus rapidly eluted from the column. The chemical nature of the material is not clear, but it can be assumed that the dispersive surface where interaction with the small molecules can take place probably contains hydrocarbon chains like a reversed phase. [Pg.225]

Yang, Y.-B., Harrison, K., and Kindsvater, J., Characterization of a novel stationary phase derived from a hydrophilic polystyrene-based resin for protein cation-exchange high-performance liquid chromatography, /. Chromatogr. A, 723, 1, 1996. [Pg.280]

The application of polymer monoliths in 2D separations, however, is very attractive in that polymer-based packing materials can provide a high performance, chemically stable stationary phase, and better recovery of biological molecules, namely proteins and peptides, even in comparison with C18 phases on silica particles with wide mesopores (Tanaka et al., 1990). Microchip fabrication for 2D HPLC has been disclosed in a recent patent, based on polymer monoliths (Corso et al., 2003). This separation system consists of stacked separation blocks, namely, the first block for ion exchange (strong cation exchange) and the second block for reversed-phase separation. This layered separation chip device also contains an electrospray interface microfabricated on chip (a polymer monolith/... [Pg.152]

Because plasma and urine are both aqueous matrixes, reverse-phase or polar organic mode enantiomeric separations are usually preferred as these approaches usually requires less elaborate sample preparation. Protein-, cyclodextrin-, and macrocyclic glycopeptide-based chiral stationary phases are the most commonly employed CSPs in the reverse phase mode. Also reverse phase and polar organic mode are more compatible mobile phases for mass spectrometers using electrospray ionization. Normal phase enantiomeric separations require more sample preparation (usually with at least one evaporation-to-dryness step). Therefore, normal phase CSPs are only used when a satisfactory enantiomeric separation cannot be obtained in reverse phase or polar organic mode. [Pg.328]

Size-exclusion HPLC (SE-HPLC) separates proteins on the basis of size and shape. As most soluble proteins are globular (i.e. roughly spherical in shape), separation is essentially achieved on the basis of molecular mass in most instances. Commonly used SE-HPLC stationary phases include silica-based supports and cross-linked agarose of defined pore size. Size-exclusion systems are most often used to analyse product for the presence of dimers or higher molecular mass aggregates of itself, as well as proteolysed product variants. [Pg.184]

As yet, the number of applications is limited but is likely to grow as instrumentation, mostly based on existing CE systems, and columns are improved and the theory of CEC develops. Current examples include mixtures of polyaromatic hydrocarbons, peptides, proteins, DNA fragments, pharmaceuticals and dyes. Chiral separations are possible using chiral stationary phases or by the addition of cyclodextrins to the buffer (p. 179). In theory, the very high efficiencies attainable in CEC mean high peak capacities and therefore the possibility of separating complex mixtures of hundreds of... [Pg.648]

These separations can be carried out using a silica-based bonded phase however, the important advantage of organic polymer stationary phase materials is their chemical stability. The columns can be washed by using an alkaline solution after a certain number of injections. According to the chromatograms, the proteins in serum are completely eluted and nothing remains inside the column. However, the pressure drop in this type of analysis... [Pg.52]

Chiral separations result from the formation of transient diastereomeric complexes between stationary phases, analytes, and mobile phases. Therefore, a column is the heart of chiral chromatography as in other forms of chromatography. Most chiral stationary phases designed for normal phase HPLC are also suitable for packed column SFC with the exception of protein-based chiral stationary phases. It was estimated that over 200 chiral stationary phases are commercially available [72]. Typical chiral stationary phases used in SFC include Pirkle-type, polysaccharide-based, inclusion-type, and cross-linked polymer-based phases. [Pg.221]

Haginaka J. 2001. Protein-based chiral stationary phases for high performance liquid chromatography enantiosepara-tions. J Chromatogr A 906 253-273. [Pg.37]

Armstrong et al. ° first introduced chiral stationary phases based on macrocyclic antibiotics. Vancomycin, ristocetin A, teicoplanin, avoparcin, rifamycin B and thiostrepton are used as chiral selectors. They posses a broad enantiorecognition range, similar to protein based CSPs. However, CSPs based on macrocyclic antibiotics show higher stability and capacities.Underivatized amino acids, N-derivatized amino-acids, acidic compounds, neutrals, amides, esters and amines can be separated.The first four of the above-mentioned chiral selectors appear to have the largest enantiorecognition range.The selectors can also be derivatized to obtain different enantioselectivities. [Pg.472]

Aubry, A.E., Markoglou, N., Descorps, V., Wainer, I.W. and felix, G. (1994) Evaluation of a chiral stationary phase based on mixed immobilized proteins. Journal of Chromatography. A, 685, 1-6. [Pg.217]

Due to their defined monomodal macropore distribution (see Section 1.2.1), monolithic stationary phases, based on polymerization of organic precursors, are predestined for efficient and swift separation of macromolecules, like proteins, peptides, or nucleic acids, as their open-pore structure of account for enhanced mass transfer due to convection rather than diffusion. In fact, most of the applications of organic monolith introduced and investigated in literature are directed to analysis of biomolecule chromatography [29]. [Pg.31]


See other pages where Stationary phases protein based is mentioned: [Pg.59]    [Pg.73]    [Pg.393]    [Pg.363]    [Pg.115]    [Pg.494]    [Pg.50]    [Pg.52]    [Pg.57]    [Pg.99]    [Pg.219]    [Pg.220]    [Pg.315]    [Pg.21]    [Pg.23]    [Pg.79]    [Pg.206]    [Pg.205]    [Pg.217]    [Pg.297]    [Pg.704]    [Pg.705]    [Pg.377]    [Pg.54]    [Pg.128]    [Pg.27]    [Pg.28]    [Pg.101]    [Pg.24]    [Pg.427]    [Pg.160]    [Pg.223]    [Pg.236]    [Pg.236]    [Pg.205]   
See also in sourсe #XX -- [ Pg.446 ]