Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standardization Schemes

The magnitudes of preanaiyticai sources of variation are clearly not equal for different analytes (see Chapter 17).Mt could therefore be argued that we should consider only those factors that cause unwanted variation in the biological quantity for which we want to produce reference values. Body posture during specimen collection is, for instance, highly relevant for the establishment of reference values for non-diffiisible analytes, such as albumin in serum, but irrelevant for establishment of serum sodium values.  [Pg.431]

On the other hand, several constituents are routinely analyzed in the same clinical specimen. It would therefore be unpractical to devise special systems for every single type of quantity. For that reason, three standardized procedures for blood specimen collection by venipuncture have been rec-ommended h (1) collection in the morning from hospitalized patients, (2) collection in the morning from ambulatory patients, and (3) collection in the afternoon from ambulatory patients. Table 16-2 summarizes these procedures. [Pg.431]

Such schemes of standardization have to be modified depending on local conditions and necessities and on the intended use of the produced reference values. Published checklists may be helpful in the design of a scheme. [Pg.431]

A special problem is caused by drugs taken by individuals before specimen collection. We may distinguish between indispensable and dispensable medication. The latter type of drugs should always be avoided for at least 48 hours. The use of indispensable drugs, such as contraceptive pills or essential medication, may be a criterion for exclusion or partitioning. [Pg.431]

In emergency or other unplanned clinical situations, even a partial application of the standardized procedure for collection has been shown to be of great value.  [Pg.431]


In this paper we present a number of time integrators for various problems ranging from classical to quantum molecular dynamics. These integrators share some common features they are new, they are second-order accurate and time-reversible, they improve substantially over standard schemes in well-defined model situations — and none of them has been tested on real applications at the time of this writing. This last feature will hopefully change in the near future [20]. [Pg.421]

There are two standard schemes for the machine representation of a number, called fixed-point and floating-point. The older electronic machines used only fixed-point. In its most usual form, every number was assumed to satisfy... [Pg.50]

One of the main problems for the annotation and classification of the biological space is the lack of a standard scheme for all protein families. Even within families, different classification schemes coexist and are being used by different research communities. This aspect hampers enormously any chemogenomic initiative aimed at integrating chemical and biological spaces with novel computational techniques. The following provides an overview of the classification schemes currently in use for the main therapeutically relevant protein families. [Pg.41]

As a consequence of the transformation, the equation of motion depends on three extra coordinates which describe the orientation in space of the rotating local system. Furthermore, there are additional terms in the Hamiltonian which represent uncoupled momenta of the nuclear and electronic motion and moment of inertia of the molecule. In general, the Hamiltonian has a structure which allows for separation of electronic and vibrational motions. The separation of rotations however is not obvious. Following the standard scheme of the various contributions to the energy, one may assume that the momentum and angular momentum of internal motions vanish. Thus, the Hamiltonian is simplified to the following form. [Pg.150]

Phthalylsulfathiazolee Phthalylsulfathiazolee, (iV -phthaloylsnlfanilamido)-thiazole (33.1.24), is also one of the sulfanilamides in which the free amino gronp in the benzene ring is modified, which can evidently be explained by the localization of the place of its action. It is synthesized by reacting sulfathiazolee (33.1.23), which is synthesized by the standard scheme from 4-acetylaminobenzenesulfonyl chloride and 2-aminothiazole, with phthalic anhydride [26,27],... [Pg.505]

The GRECP versions with separable correction and constructed for these generator states employing the standard scheme [17, 18, 19, 24]. The GRECP operator with the separable correction has the form... [Pg.233]

What would you change, complete or develop in this model I would work in a Chemical Leasing company in cleaning with hydrocarbon solvent with involvement of other companies from different sectors. At the same time 1 would like to work on the development a standard scheme for certification of Chemical Leasing. ... [Pg.74]

The scheme for oxygen exchange in Pi based upon the standard scheme for ester hydrolysis (Scheme V) is... [Pg.414]

This equation is analogous to the equation describing fractionation of copolymers by fractional precipitation 56). To obtain uniform fractions, it is necessary to use cross-fractionation 56,57) in both cases since under a standard scheme of fractionation the macromolecules with different a and b but with similar denominator at the right-hand side of Eq. (17) will equally distribute between the solution and the polycomplex (between the diluted and the concentrated phases, respectively). [Pg.155]

A choice between the conventional (or classical) and ion radical mechanism is a very important issue. The ion radical pathway can lead to products of the desired structure or can make the conversion conditions more mild or can change the reactivity of the secondary intermediate particles. If ion radicals form and react in a solvent cage, the reaction proceeds rapidly, and product yields are indistinguishable from standard schemes, then the role that ion radicals play is only of theoretical interest and is, thus far, not essential for practical organic synthesis. [Pg.264]

A relatively simple model could be derived from the above standard scheme, suppressing 02 ... [Pg.464]

Because Equation 6.53, which is sometimes called the Coulson scheme for net atomic charges, is based on the NDDO approximation, it cannot be applied properly for ab initio methods. Here, a standard scheme to quantify net atomic charges is Mulliken population analysis (Mulliken, 1955 1962), despite some well-known deflciences such as its strong dependence on the basis set and its apparent lack of convergence with increasing basis set size. Nonetheless, Mulliken charges may... [Pg.113]

The standard scheme has been the most popular one for the last 20 years or so. The harmonic scheme gets its name because if the bath is harmonic (more precisely, if F can be represented as a linear combination of harmonic coordinates), then this scheme is exact (16,19). By comparing these schemes to results from exactly solvable models we have concluded that the standard scheme is really not very accurate at high frequencies and that the harmonic and Egelstaff schemes are more promising (5,6). A fourth scheme satisfying detailed balance,... [Pg.689]


See other pages where Standardization Schemes is mentioned: [Pg.468]    [Pg.99]    [Pg.114]    [Pg.23]    [Pg.72]    [Pg.264]    [Pg.240]    [Pg.240]    [Pg.1148]    [Pg.1163]    [Pg.1371]    [Pg.130]    [Pg.197]    [Pg.506]    [Pg.507]    [Pg.342]    [Pg.345]    [Pg.403]    [Pg.461]    [Pg.566]    [Pg.760]    [Pg.239]    [Pg.468]    [Pg.292]    [Pg.190]    [Pg.76]    [Pg.76]    [Pg.77]    [Pg.395]    [Pg.311]    [Pg.359]    [Pg.610]    [Pg.688]    [Pg.124]    [Pg.168]    [Pg.610]    [Pg.479]    [Pg.345]   


SEARCH



Finite-volume scheme standard

Secure standard fail-stop signature scheme

Standard Galerkin scheme

Standard Malaysian Rubber scheme

Standard fail-stop signature scheme

Standard finite-volume schemes for moments

Standard ordinary digital signature scheme

Standard oxidation scheme

© 2024 chempedia.info