Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spectroscopic techniques measurements

An alternative to laser flash photolysis which is useful for studying opaque (but reflecting) samples, is diffuse reflectance spectroscopy [27]. This spectroscopic technique measures the ratio of the intensity of light reflected from the sample, I, to that reflected from a background or reference reflective surface, Iq. In time-resolved... [Pg.90]

There has been considerable recent interest in chiral CEPs in which polymer chains (or aggregates of polymer chains) adopt a one-handed helical arrangement. Circular dichroism (CD) spectroscopy provides a powerful tool to probe the chain conformation (and preferred hand) in such chiral polymers. This spectroscopic technique measures the difference in absorption of left- and right-hand circularly polarized light by a chiral sample as follows ... [Pg.47]

The dissociation of carbon dioxide induced by both a silent electric discharge and photons of wavelength 812—1216 A has been investigated. The photoionization of inter alia CO2 by soft A"-rays has also been studied the total and relative abundances of the thermal-energy ions produced by absorption of 0.28, 1.25, and 1.5 keV A -rays in CO2 (CO2, CO, CO+, C+, 0+, C +) have been measured using a mass-spectroscopic technique. Measurements of relative 83 concentrations following the flash photolysis of OCS diluted with COg have been used to investigate the mechanism of the polymerization of atomic sulphur, one of the principal products of the photolysis ... [Pg.272]

Molecular chirality is most often observed experimentally through its optical activity, which is the elfect on polarized light. The spectroscopic techniques for measuring optical activity are optical rotary dispersion (ORD), circular di-chroism (CD), and vibrational circular dichroism (VCD). [Pg.113]

Inorganic flocculants are analyzed by the usual methods for compounds of this type. Residual metal ions in the effluent are measured by spectroscopic techniques such as atomic absorption. Polymeric aluminum species formed in solution have been characterized by Al-nmr (64). [Pg.36]

Measuring Protein Sta.bihty, Protein stabihty is usually measured quantitatively as the difference in free energy between the folded and unfolded states of the protein. These states are most commonly measured using spectroscopic techniques, such as circular dichroic spectroscopy, fluorescence (generally tryptophan fluorescence) spectroscopy, nmr spectroscopy, and absorbance spectroscopy (10). For most monomeric proteins, the two-state model of protein folding can be invoked. This model states that under equihbrium conditions, the vast majority of the protein molecules in a solution exist in either the folded (native) or unfolded (denatured) state. Any kinetic intermediates that might exist on the pathway between folded and unfolded states do not accumulate to any significant extent under equihbrium conditions (39). In other words, under any set of solution conditions, at equihbrium the entire population of protein molecules can be accounted for by the mole fraction of denatured protein, and the mole fraction of native protein,, ie. [Pg.200]

The objective ia any analytical procedure is to determine the composition of the sample (speciation) and the amounts of different species present (quantification). Spectroscopic techniques can both identify and quantify ia a single measurement. A wide range of compounds can be detected with high specificity, even ia multicomponent mixtures. Many spectroscopic methods are noninvasive, involving no sample collection, pretreatment, or contamination (see Nondestructive evaluation). Because only optical access to the sample is needed, instmments can be remotely situated for environmental and process monitoring (see Analytical METHODS Process control). Spectroscopy provides rapid real-time results, and is easily adaptable to continuous long-term monitoring. Spectra also carry information on sample conditions such as temperature and pressure. [Pg.310]

Historically, EELS is one of the oldest spectroscopic techniques based ancillary to the transmission electron microscope. In the early 1940s the principle of atomic level excitation for light element detection capability was demonstrated by using EELS to measure C, N, and O. Unfortunately, at that time the instruments were limited by detection capabilities (film) and extremely poor vacuum levels, which caused severe contamination of the specimens. Twenty-five years later the experimental technique was revived with the advent of modern instrumentation. The basis for quantification and its development as an analytical tool followed in the mid 1970s. Recent reviews can be found in the works by Joy, Maher and Silcox " Colliex and the excellent books by Raether and Egerton. ... [Pg.137]

Electron spectroscopic techniques require vacuums of the order of 10 Pa for their operation. This requirement arises from the extreme surface-specificity of these techniques, mentioned above. With sampling depths of only a few atomic layers, and elemental sensitivities down to 10 atom layers (i. e., one atom of a particular element in 10 other atoms in an atomic layer), the techniques are clearly very sensitive to surface contamination, most of which comes from the residual gases in the vacuum system. According to gas kinetic theory, to have enough time to make a surface-analytical measurement on a surface that has just been prepared or exposed, before contamination from the gas phase interferes, the base pressure should be 10 Pa or lower, that is, in the region of ultrahigh vacuum (UHV). [Pg.9]

In addition to qualitative analysis of nearly all the elements of the periodic table, EEL spectra also enable determination of the concentration of a single element which is part of the transmitted volume and hence gives rise to a corresponding ionization edge. As in all comparable spectroscopic techniques, for quantification the net edge signal, which is related to the number N of excited atoms, must be extracted from the raw data measured. The net intensity 4 of the feth ionization shell of an individual element is directly connected to this number, N, multiplied by the partial cross-section of ionization ) and the intensity Iq of the incident electron beam, i.e. ... [Pg.65]

The form of the Plmn will be discussed later, because it is instructive to develop the argument by considering next the information which is obtained from any spectroscopic technique. Figure 2a shows a direction within a unit of structure which is defined by the polar and azimuthal angles (, r ). For example, this could be the direction defining the change in dipole moment (the transition moment vector) in an infra-red spectroscopic measurement. The spectroscopic measurements provide... [Pg.84]

The main problem in Eas0 vs. correlations is that the two experimental quantities are as a rule measured in different laboratories with different techniques. In view of the sensitivity of both parameters to the surface state of the metal, their uncertainties can in principle result of the same order of magnitude as AX between two metals. On the other hand, it is rare that the same laboratory is equipped for measuring both single-crystal face is not followed by a check of its perfection by means of appropriate spectroscopic techniques. In these cases we actually have nominal single-crystal faces. This is probably the reason for the observation of some discrepancies between differently prepared samples with the same nominal surface structure. Fortunately, there have been a few cases in which both Ea=0 and 0 have been measured in the same laboratory these will be examined later. Such measurements have enabled the resolution of controversies that have long persisted because of the basic criticism of Eazm0 vs. 0 plots. [Pg.157]

Frequently, electrochemical information can be interpreted better in the presence of additional nonelectrochemical information. Typically, however, there is one significant restriction electrochemical and spectroscopic techniques often do not detect exactly the same mechanisms. With spectroscopic measurements (e.g., infrared spectroscopy), products that are formed by electrochemical processes may be detected. In other cases (luminescence techniques) mechanisms may be found by which charge carriers are trapped and recombine. Other techniques (electroreflection studies) allow the nature of electronic transitions to be determined and provide information on the presence or absence of an electric field in the surface of an electrode. With no traditional technique, however, is it... [Pg.435]

The non situ experiment pioneered by Sass uses a preparation of an electrode in an ultrahigh vacuum through cryogenic coadsorption of known quantities of electrolyte species (i.e., solvent, ions, and neutral molecules) on a metal surface. " Such experiments serve as a simulation, or better, as a synthetic model of electrodes. The use of surface spectroscopic techniques makes it possible to determine the coverage and structure of a synthesized electrolyte. The interfacial potential (i.e., the electrode work function) is measured using the voltaic cell technique. Of course, there are reasonable objections to the UHV technique, such as too little water, too low a temperature, too small interfacial potentials, and lack of control of ionic activities. ... [Pg.32]

The microheterogeneity coefficient was introduced only for the description of the microstructure of binary copolymers with symmetric units. At increased number of unit types and/or when account is taken of structural isomerism, the role of Km will be performed by other parameters analogous to it. A general strategy for the choice of these latter has been elaborated in detail [12], while their values have been measured via NMR spectroscopic techniques for a variety of polycondensation polymers [13]. [Pg.167]


See other pages where Spectroscopic techniques measurements is mentioned: [Pg.253]    [Pg.71]    [Pg.647]    [Pg.228]    [Pg.253]    [Pg.71]    [Pg.647]    [Pg.228]    [Pg.9]    [Pg.310]    [Pg.369]    [Pg.559]    [Pg.1868]    [Pg.33]    [Pg.1]    [Pg.318]    [Pg.394]    [Pg.398]    [Pg.30]    [Pg.732]    [Pg.743]    [Pg.194]    [Pg.192]    [Pg.1215]    [Pg.163]    [Pg.153]    [Pg.100]    [Pg.168]    [Pg.44]    [Pg.83]    [Pg.100]    [Pg.338]    [Pg.178]    [Pg.433]    [Pg.434]    [Pg.4]    [Pg.174]    [Pg.29]    [Pg.3]   
See also in sourсe #XX -- [ Pg.97 ]




SEARCH



Spectroscopic Techniques for Measuring Collision-Induced Transitions in the Electronic Ground State of Molecules

Spectroscopic measurements

Spectroscopic techniques

Spectroscopic techniques luminescence lifetime measurements

Spectroscopic techniques solid-state measurements

Spectroscopical Measurements

© 2024 chempedia.info