Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spectroscopic techniques comparative analyses

In addition to qualitative analysis of nearly all the elements of the periodic table, EEL spectra also enable determination of the concentration of a single element which is part of the transmitted volume and hence gives rise to a corresponding ionization edge. As in all comparable spectroscopic techniques, for quantification the net edge signal, which is related to the number N of excited atoms, must be extracted from the raw data measured. The net intensity 4 of the feth ionization shell of an individual element is directly connected to this number, N, multiplied by the partial cross-section of ionization ) and the intensity Iq of the incident electron beam, i.e. ... [Pg.65]

Molecular spectroscopic techniques have been widely used in pharmaceutical analysis for both qualitative (identification of chemical species) and quantitative purposes (determination of concentration of species in pharmaceutical preparations). In many cases, they constitute effective alternatives to chromatographic techniques as they provide results of comparable quality in a more simple and expeditious manner. The differential sensitivity and selectivity of spectroscopic techniques have so far dictated their specihc uses. While UV-vis spectroscopy has typically been used for quantitative analysis by virtue of its high sensitivity, infrared (IR) spectrometry has been employed mainly for the identihcation of chemical compounds on account of its high selectivity. The development and consolidation of spectroscopic techniques have been strongly influenced by additional factors such as the ease of sample preparation and the reproducibility of measurements, which have often dictated their use in quality control analyses of both raw materials and finished products. [Pg.463]

It is clearly not sufficient merely to know the structures of the components of a reaction mixture. In order to gauge the extent of reaction, for example, or to compare one reaction condition with another it is necessary to have a quantitative measure of the components of the reaction mixture. Although this information can sometimes be given to a first approximation by some spectroscopic techniques, the maximum specificity and sensitivity is usually delivered by some form of separation of the mixture before quantification of its components. It is also worth noting that structural analysis is considerably easier for a single isolated component than for an unseparated mixmre. [Pg.237]

Many vibrational spectroscopic investigations (FTIR and Raman) concerning FA have been reported, in particular, in the early works of Baddiel and Berry [15], Bhatnagar [16], Levitt et al. [17] and Klee [18], Some studies also relate, among others, to the far-infrared region [19] and to the influence of high-pressure conditions [20], In particular, these techniques have been used for comparative analysis of FA with other apatites, such as HA or chlorapatite. [Pg.289]

The application of ESCA to the elaboration of chemical composition is well established in the case of fluorocarbon based systems for which the span in shift range for the Cu level is particularly favourable consequent upon the large electronic effect of replacing hydrogen by fluorine. In many cases comparable information may be derived from the more familiar spectroscopic techniques such as 1R and NMR one area in which ESCA comes into its own, however, is in the analysis of polymeric... [Pg.155]

The complexity of quality control for proteins, as compared to small molecules, is most evident in the requirements for proof of structure. Many small molecules can be fully characterized using a few spectroscopic techniques (e.g., NMR, IR, mass spectrometry, and UV) in conjunction with an elemental analysis. However, proving the proper structure for a protein is much more complex because 1) the aforementioned spectroscopic techniques do not provide definitive structural data for proteins, and 2) protein structure includes not only molecular composition (primary structure) but additionally, secondary, tertiary, and, in some cases, quaternary features. Clearly, no single analytical test will address all of these structural aspects hence a large battery of tests is required. [Pg.113]

The two naturally occurring isotopes of Gallium Table 2 can be used as an aid in mass spectroscopic studies. Isotopic distribution patterns have been used to model the masses and abundances of the isotopes for a given formula, and as a fingerprinting tool when used in a comparative analysis with the experimental data. This technique has recently been used for identifying the formation, mechanism, and the fragmentation pattern of Ga clusters (Figure 2), and more recently to confirm the formation of the first Ga=As... [Pg.1365]

As we have shown, based on first principles energetics, many GO stmcture models have been proposed. However, the power of energetics analysis is expected to be limited by the complexity of the GO potential energy surface, especially when artificial periodic boundary condition must be adopted with a small unit cell. In contrast, computational spectroscopy provides information, which can be directly compared with experiments. Therefore, it provides a powerful alternative in computational nanostructure characterization. XPS [37,48-52] and NMR [34-36, 53, 54] are two widely used experimental spectroscopic techniques to characterize local structures, and they are mostly used in GO structure research. [Pg.73]

Methods of characterization aim to determine the products of a reaction. The level of detail expected depends on the circumstances, and determines the range of methods required. If the aim has been to make a known compound, one needs to check its identity and purity. Fingerprinting techniques measure a spectrum or some other property and compare it with results published for known compounds and available in literature databases. Such techniques may also show whether impurities are present, but it is often desirable to check the purity of the compound independently, for example by elemental analysis. However, if the compound prepared is a new one, more thorough investigation is appropriate. The stoichiometric formula may be found by elemental analysis, and the full molecular formula in principle by mass spectrometry (MS). MS combined with other spectroscopic techniques, especially infrared (IR) and nuclear magnetic... [Pg.64]

Older methods based on solubility changes upon complexation, or on partition coefficients between aqueous solutions and hydrophobic solvents, have been shown to lead to gross errors as compared to spectroscopic techniques (40) that are also less sensitive to the formation of emulsions, micelles, and so on. The traditional X-ray analysis of inclusion compounds is of limited significance for establishing complexation between lipophilic substrates and macrocyclic host, particularly in aqueous solution. The essential hydrophobic driving force for complexation, of course, is nonexistent in the crystal. The future development of NMR methods including shielding calculations and measurements of intermolecular nuclear Overhauser effects is expected to provide the most reliable information on intercavity inclusion complexes in solution as the basis for catalytic applications. [Pg.449]

Photoacoustic (PA) spectroscopy is a combination of optical spectroscopy and calorimetry [58]. It is a technique for studying those materials that are unsuitable for the conventional transmission or reflection methodologies. It can be used to measure thermal and elastic properties of materials, to study chemical reactions, to measure the thickness of layers and thin films, and to perform a variety of other non-spectroscopic investigations. This technique can be applied to different types of inorganic, organic and biological materials in the gas-, liquid-, or solid phase. Nowadays, PA spectroscopy is mainly employed for material characterization [59]. Compared with other spectroscopic techniques, PA spectroscopy provides a non-destructive analysis and does not require any sample preparation. [Pg.256]

The judicious selection of an ionization method is a very important step toward a successful analysis. Indeed, mass spectrometric results should always be described with reference to the ion source employed. The choice of an ionization method may also depend on other factors, such as the molecular mass and polarity of the canpound and whetha GC or LC is being used for the initial separation of the constituents of mixtures. It is emphasized that mass spectra are usually reproducible when experimental parametas are duplicated. The consequence of the wide variety of choices of techniques and strategies available is that in mass spectrometry, compared with other spectroscopic techniques such as UV and infrared (IR), it is particularly important to be familiar with alternative instrument types, analytical techniques, aud operatiaial parameters. [Pg.30]


See other pages where Spectroscopic techniques comparative analyses is mentioned: [Pg.183]    [Pg.246]    [Pg.272]    [Pg.138]    [Pg.100]    [Pg.385]    [Pg.60]    [Pg.709]    [Pg.416]    [Pg.36]    [Pg.246]    [Pg.231]    [Pg.68]    [Pg.191]    [Pg.926]    [Pg.161]    [Pg.1]    [Pg.843]    [Pg.50]    [Pg.288]    [Pg.25]    [Pg.35]    [Pg.355]    [Pg.244]    [Pg.177]    [Pg.154]    [Pg.499]    [Pg.181]    [Pg.122]    [Pg.122]    [Pg.1364]    [Pg.143]    [Pg.460]    [Pg.597]    [Pg.102]    [Pg.587]    [Pg.164]    [Pg.260]   
See also in sourсe #XX -- [ Pg.126 ]




SEARCH



Analysis techniques

Comparative analysis

Spectroscopic analysis

Spectroscopic techniques

© 2024 chempedia.info