Spectrometer display

Figure 1. Relative locations of the most sensitive absorption lines for selected elements in the two-dimensional echelle spectrometer display (30). Figure 1. Relative locations of the most sensitive absorption lines for selected elements in the two-dimensional echelle spectrometer display (30).
A preliminary study has also been made of the further reactions of the S2 intermediate by flash photolysis with kinetic mass spectrometry. About 0.2 torr of COS (H S or CS2) admixed with co. 15 torr He, were flashed in a suitably designed apparatus and the resulting gas mixtures analyzed at a particular m/e value by a fast response mass spectrometer displaying the concentration vs. delay time curve on an oscilloscope. All polymeric states between S2 and Sg were detected with the possible exception of S7, but no species higher than Sg were present. Representative ion intensity vs. delay time plots for Sg, S4, Sg, Sg, and Sg are shown in Figure 4. The S3 and Sg species could have arisen from the disproportionation reaction of S4. It is seen that S2 decays fast with the simultaneous formation of the higher molecular weight polymers. The rate of formation and decay of Sg is the slowest and its spectrum persists for many tens of seconds. [Pg.150]

The simplest CD spectrometers display the main features for the side-chains of coded aromatic a-amino acids, for example, since these features are within the easily accessible UV wavelength range. Flowever, the additional CD data obtained for peptides and proteins by penetration to shorter wavelengths (A< 200 nm) calls for more sophisticated instrumentation and interpretations described later in this chapter would not have been possible without this penetration. [Pg.39]

Partial pressures were measured using a Dycor M200M quadru-pole mass spectrometer. In its PRESSURE-TIME mode the mass spectrometer displayed and recorded the partial pressures of... [Pg.44]

With the advent of the suprasensitive EPR method of radical detection, it was natural that it should be used to observe and identify the radicals produced by the photodissociation of adsorbed gas molecules. Thus, silica gel with adsorbed methyl iodide subjected to a prolonged irradiation by ultraviolet light at 77°K and transferred to the resonance cavity of a EPR spectrometer displays the pattern, reproduced in Fig. 20a 131), which belongs to adsorbed methyl radicals, CHj split... [Pg.278]

In this configuration the tandem mass spectrometer displays the best performances in quantitation jobs. In fact, sensitivity and reproducibility are directly... [Pg.362]

Each vibrational peak within an electronic transition can also display rotational structure (depending on the spacing of the rotational lines, the resolution of the spectrometer, and the presence or absence of substantial line broadening effects such as... [Pg.415]

Modern mass spectrometers are interfaced with computerized data handling sys terns capable of displaying the mass spectrum according to a number of different for mats Bar graphs on which relative intensity is plotted versus m z are the most common Figure 13 40 shows the mass spectrum of benzene m bar graph form... [Pg.568]

Photomultipliers are used as detectors in the single-channel instruments. GaAs cathode tubes give a flat frequency response over the visible spectrum to 800 nm in the near IR. Contemporary Raman spectrometers use computers for instrument control, and data collection and storage, and permit versatile displays. [Pg.432]

Sequential instruments. The diagram of the light path of the Thermo Electron-200 ICP spectrometer is shown in Fig. 20.14. The plasma is located in the upper centre of the instrument just above the nebuliser, which is powered by a computer-controlled peristaltic pump. Communication with the instrument takes place on a video display, which not only guides the operator through the use of the system, but also provides graphics to simplify methods development. [Pg.776]

Room-temperature fluorescence (RTF) has been used to determine the emission characteristics of a wide variety of materials relative to the wavelengths of selected Fraunhofer lines in support of the Fraunhofer luminescence detector remote-sensing instrument. RTF techniques are now used in the compilation of excitation-emission-matrix (EEM) fluorescence "signatures" of materials. The spectral data are collected with a Perkin-Elraer MPF-44B Fluorescence Spectrometer interfaced to an Apple 11+ personal computer. EEM fluorescence data can be displayed as 3-D perspective plots, contour plots, or "color-contour" images. The integrated intensity for selected Fraunhofer lines can also be directly extracted from the EEM data rather than being collected with a separate procedure. Fluorescence, chemical, and mineralogical data will be statistically analyzed to determine the probable physical and/or chemical causes of the fluorescence. [Pg.228]

Figure 16 An NMR system using a bulk high-temperature superconducting magnet and the OPENCORE NMR spectrometer. The temperature of the bulk SCM was 40 K, while the sample space with a diameter of 24 mm was at room temperature. On the computer screen displayed is a hi FID of water taken on this system. The resonance frequency was 200.045 MHz. Figure 16 An NMR system using a bulk high-temperature superconducting magnet and the OPENCORE NMR spectrometer. The temperature of the bulk SCM was 40 K, while the sample space with a diameter of 24 mm was at room temperature. On the computer screen displayed is a hi FID of water taken on this system. The resonance frequency was 200.045 MHz.
Emission spectrometer incorporating sample and counter electrodes, means of excitation, prism or grating monochromator, photomultiplier detection system, microprocessors or computers for data processing, interference correction and data display. [Pg.289]

The ICP torch provides a rich source of free atoms and ions from the elements comprising the sample. In ICP-MS, part of the sample stream from a point close to the centre of the fireball is directed to a mass spectrometer. The resulting mass spectrum can be used to identify elements from the mass numbers of the ion peaks and the peak size for quantitative analysis. Moreover, the whole spectrum can be displayed at the same time providing qualitative analysis for a wide range of elements from one display... [Pg.307]

An indication of the flexibility imparted by computer control of such a spectrometer is given in the following list of typical facilities for spectra acquisition, display, storage and analysis. [Pg.543]

FIGURE 4.4 Arrow indicates chromatograms from three injections of SC-50267 and an internal standard [D2]SC-50267. The last injection appears near the end of the display. A VG Trio-2 mass spectrometer equipped with a thermospray LC interface was used. Samples were injected every 1.85 min—the cycle time of the autosampler (Waters WISP). (Source Chang, M. and G. Schoenhard, presentation at Pittsburgh Conference and Exposition, 1993. With permission). [Pg.123]

The polarization patterns are dependent upon the strength of the magnetic field, in which the reactions are carried out. If the reactions are carried out at high fields (i.e., notably within the NMR spectrometer), the resonances appear in antiphase - that is, there is an equal number of absorption and emission lines and no net polarization. At low field however (i.e., when the reaction is carried out at zero or a very low field and then transferred into the high field of the NMR spectrometer for subsequent investigation), the resonances display net polarization, as has been outlined by Pravica and Weitekamp [9]. [Pg.315]


See other pages where Spectrometer display is mentioned: [Pg.1122]    [Pg.257]    [Pg.265]    [Pg.290]    [Pg.292]    [Pg.431]    [Pg.177]    [Pg.267]    [Pg.170]    [Pg.444]    [Pg.448]    [Pg.871]    [Pg.957]    [Pg.102]    [Pg.15]    [Pg.1003]    [Pg.312]    [Pg.427]    [Pg.526]    [Pg.26]    [Pg.141]    [Pg.63]    [Pg.110]    [Pg.118]    [Pg.115]    [Pg.536]    [Pg.41]    [Pg.102]    [Pg.108]    [Pg.95]    [Pg.283]    [Pg.466]    [Pg.353]   