Isoproturon, dichloroprop-P. bifenox Solvent Size exclusion chromatography High-performance liquid chromatograph [77]... [Pg.7]

SPMD Triolein Nonporous LDPE membrane Hydrophobic organic compounds Integrative 1 month Dialysis in organic solvents, size exclusion chromatography 29... [Pg.53]

For the classical form of size exclusion chromatography in organic solvents, packings based on highly cross-linked styrene-divinylbenzene are used. For SEC of polar polymers using polar or aqueous solvents, packings based on a polar methacrylate polymer are used. Diol-derivatized silica is used for the separation of proteins and other polar polymers. The different packings will be discussed in sections dedicated to their different application areas. [Pg.326]

Generally, size exclusion chromatography is carried out using columns with an internal diameter of 7.8 mm. However, some SEC applications require the use of expensive solvents. For this purpose, size exclusion columns with a smaller internal diameter (4.6 mm) have been developed. Of course one should use proportionally lower flow rates with narrow-bore columns. If the standard column size uses a flow rate of 1 ml/min, then the smaller 4.6-mm columns should be used at a flow rate of 0.35 ml/min. This provides the same linear velocity as 1 ml/min on 7.8-mm columns. The decreased flow rate reduces solvent consumption and solvent disposal cost. The performance of the smaller diameter columns is not compromised if properly optimized instrumentation is used. [Pg.333]

Styragel columns are compatible with most solvents commonly used in size exclusion chromatography. Exceptions are found on both sides of the polarity scale the use of standard general-purpose Styragel columns with aliphatic hydrocarbons or with alcohols (except hexafluoroisopropanol) and water is generally not recommended. However, it is possible to pack columns in special solvents for special-purpose applications. The interested user should contact Waters for additional information. [Pg.341]

Solvent conversion of columns designed for aqueous size exclusion chromatography is rarely a problem. However, it should always be carried out at slow flow rates. For Ultrahydrogel columns, the recommended flow rate for a solvent conversion is below 0.3 ml/min. One should typically use 0.1 ml/min for most solvent conversion procedures. [Pg.346]

For the size exclusion chromatography of proteins on silica-hased diol packings, it is generally recommended to use fully aqueous mobile phases with a salt concentration between 0.1 and 0.3 M. In general, a phosphate buffer around pH 7 is used as the mobile phase. Under these circumstances, the tertiary structure of most proteins is preserved without difficulty and the interaction of proteins with each other is minimized. However, other inorganic buffers or combinations of buffers with organic solvents can be used without difficulties for special applications. [Pg.347]

A more complicated, but flexible, system has been reported by Blomberg et al. (46). Here, size exclusion chromatography (SEC), normal phase EC (NPLC) and GC were coupled for the characterization of restricted (according to size) and selected (according to polarity) fractions of long residues. The seemingly incompatible separation modes, i.e. SEC and NPLC, are coupled by using an on-line solvent-evaporation step. [Pg.402]

In addition to the insoluble polymers described above, soluble polymers, such as non-cross-linked PS and PEG have proven useful for synthetic applications. However, since synthesis on soluble supports is more difficult to automate, these polymers are not used as extensively as insoluble beads. Soluble polymers offer most of the advantages of both homogeneous-phase chemistry (lack of diffusion phenomena and easy monitoring) and solid-phase techniques (use of excess reagents and ease of isolation and purification of products). Separation of the functionalized matrix is achieved by either precipitation (solvent or heat), membrane filtration, or size-exclusion chromatography [98,99]. [Pg.87]

When the full distribution is needed, it is measured by size-exclusion chromatography (also called gel permeation chromatography). This is a solution technique that requires dissolution of the polymer in a reasonable solvent such as tetrahydrofuran or tetrachlorlobenzene. For polymers that require exotic solvents or solution temperatures above about 150°C, a simple measurement of solution viscosity can be a useful surrogate for the actual molecular weight. The viscosity of the pure polymer (i.e., a polymer melt viscosity) can also be used. Such simplified techniques are often satisfactory for routine quality control, particularly for condensation polymers such as PET that vary in average molecular weight but usually have a polydispersity of 2. [Pg.472]

ISEC is a size-exclusion chromatography technique, in which the stationary phase is the CFP to be to characterized [16-18] and the eluates are geometrically well-defined steric probes. From the determined retention volumes in a given solvent and on the basis of suitable morphological models, ISEC analysis provides the... [Pg.202]


See other pages where Solvents size exclusion chromatography is mentioned: [Pg.129]    [Pg.113]    [Pg.129]    [Pg.113]    [Pg.206]    [Pg.772]    [Pg.45]    [Pg.532]    [Pg.350]    [Pg.259]    [Pg.221]    [Pg.431]    [Pg.446]    [Pg.111]    [Pg.221]    [Pg.353]    [Pg.159]    [Pg.219]    [Pg.316]    [Pg.326]    [Pg.326]    [Pg.327]    [Pg.328]    [Pg.337]    [Pg.346]    [Pg.367]    [Pg.460]    [Pg.611]    [Pg.231]    [Pg.311]    [Pg.315]    [Pg.94]    [Pg.149]    [Pg.90]    [Pg.115]    [Pg.16]    [Pg.100]    [Pg.91]    [Pg.226]    [Pg.242]    [Pg.79]   