Decaestecker, T.N. et al., Evaluation of automated single mass spectrometry to tandem mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole time-of-flight mass spectrometer, Rapid Commun. Mass Spectrom., 14, 1787, 2000. [Pg.56]

In modem mass spectrometry, ion collectors (detectors) are generally based on the electron multiplier and can be separated into two classes those that detect the arrival of all ions sequentially at a point (a single-point ion collector) and those that detect the arrival of all ions simultaneously (an array or multipoint collector). This chapter compares the uses of single- and multipoint ion collectors. For more detailed discussions of their construction and operation, see Chapter 28, Point Ion Collectors (Detectors), and Chapter 29, Array Collectors (Detectors). In some forms of mass spectrometry, other methods of ion detection can be used, as with ion cyclotron instmments, but these are not considered here. [Pg.211]

There is potential confusion in the use of the word array in mass spectrometry. Historically, array has been used to describe an assemblage of small single-point ion detectors (elements), each of which acts as a separate ion current generator. Thus, arrival of ions in one of the array elements generates an ion current specifically from that element. An ion of any given m/z value is collected by one of the elements of the array. An ion of different m/z value is collected by another element. Ions of different m/z value are dispersed in space over the face of the array, and the ions are detected by m/z value at different elements (Figure 30.4). [Pg.213]

In conventional mass spectrometry with electric and magnetic sectors arranged in-hne (see Chapter 26), an ion beam consists of a stream of ions of all m/z values, which is separated into individual m/z values by the magnetic sector before being collected by single-point or multipoint detectors (see Chapters 28 and 29). [Pg.407]

SIM. selected (or single) ion monitoring SIMS, secondary ion mass spectrometry SIR. selected (or single) ion recording... [Pg.446]

For marble provenance studies, the most successful technique seems to be the measurement, through mass spectrometry, of the abundance ratios of the stable isotopes of carbon and oxygen (116). However, no single technique appears to provide unequivocal results, especially in cases such as the different Mediterranean sources, and a combination is often necessary to arrive at an approximate place of origin (117). [Pg.423]

Confirmation of the identities of nitrosamines generally is accompHshed by gas chromatography—mass spectrometry (gc/ms) (46,87). High resolution gc/ms, as well as gc/ms in various single-ion modes, can be used as specific detectors, especially when screening for particular nitrosamines (87) (see Analytical LffiTHODS Trace and residue analysis). [Pg.109]

The main advantages of the ms/ms systems are related to the sensitivity and selectivity they provide. Two mass analyzers in tandem significantly enhance selectivity. Thus samples in very complex matrices can be characterized quickly with Htde or no sample clean-up. Direct introduction of samples such as coca leaves or urine into an ms or even a gc/lc/ms system requires a clean-up step that is not needed in tandem mass spectrometry (28,29). Adding the sensitivity of the electron multiplier to this type of selectivity makes ms/ms a powerhil analytical tool, indeed. It should be noted that introduction of very complex materials increases the frequency of ion source cleaning compared to single-stage instmments where sample clean-up is done first. [Pg.405]

When the gas chromatograph is attached to a mass spectrometer, a very powerful analytical tool (gas chromatography-mass spectrometry, GC-MS) is produced. Vapour gas chromatography allows the analyses of mixtures but does not allow the definitive identification of unknown substances whereas mass spectrometry is good for the identification of a single compound but is less than ideal for the identification of mixtures of... [Pg.17]

A somewhat related technique is that of laser ionization mass spectrometry (LIMS), also known as LIMA and LAMMA, where a single pulsed laser beam ablates material and simultaneously causes some ionization, analogous to samples beyond the outer surface and therefore is more of a bulk analysis technique it also has severe quantiBaction problems, often even more extreme than for SIMS. [Pg.561]

Surface Analysis by Laser Ionization Post-Ionization Secondary Ion Mass Spectrometry Multi-Photon Nonresonant Post Ionization Multiphoton Resonant Post Ionization Resonant Post Ionization Multi-Photon Ionization Single-Photon Ionization... [Pg.768]

Properties of panal (Nakamura etal., 1988a). Purified panal is a colorless, amorphous solid, soluble in alcohols, water, ethyl acetate, and chloroform. The absorption spectrum (Fig. 9.3) shows a single peak (A.max 217nm, e 15,300). Optical rotation [a]D —17° (c 0.9, methanol). Mass spectrometry and NMR analysis showed that panal is a sesquiterpene aldehyde, C15H18O5 (Mr 278.30), with the structure shown below. [Pg.278]

Gas Chromatography and Mass Spectrometry A Practical Guide is designed to be a valuable resource to the GC/MS user by incorporating much of the practical information necessary for successful GC/MS operation into a single source. With this purpose in mind, the authors have kept the reading material practical and as brief as possible. This guide should be immediately valuable to the novice, as well as to the experienced GC/MS user who may not have the breadth of experience covered in this book. [Pg.196]

Commercial Instruments Because of the proliferation of applications of mass spectrometry in organic and analytical chemistry, there are instruments marketed by numerous companies today. Some of the popular ones are the low resolution, single focusing model 21-490 and the high resolution, double focusing models, 21-492 and 21-110 of Du Pont de Nemours Co, and the double focusing model MS-9 of Associated Electrical Industries... [Pg.49]

In the single-chamber type reactor (Fig. 4.1b) all three electrodes (catalyst-working (W), counter (C) and reference (R)), electrode are all in the same chamber and are all exposed to the reactants and products.1 3 In this case the counter and reference electrodes must be made from a catalytically inert (e.g. Au) material for otherwise the catalytic rate on them will obscure the measured (via gas-chromatography or mass-spectrometry, Fig. 4.2) rate on the catalyst-working electrode. [Pg.111]

The total number of protons and neutrons in a nucleus is called the mass number, A, of the atom. A nucleus of mass number A is about A times as heavy as a hydrogen atom, which has a nucleus that consists of a single proton. Therefore, if we know that an atom is a certain number of times as heavy as a hydrogen atom, then we can infer the mass number of the atom. For example, because mass spectrometry shows that the three varieties of neon atoms are 20, 21, and 22 times as heavy as a hydrogen atom, we know that the mass numbers of the three types of neon atoms are 20, 21, and 22. Because for each of them Z = 10, these neon atoms must contain 10, 11, and 12 neutrons, respectively (Fig. B.7). [Pg.42]


See other pages where Single mass spectrometry is mentioned: [Pg.211]    [Pg.67]    [Pg.2223]    [Pg.284]    [Pg.285]    [Pg.211]    [Pg.67]    [Pg.2223]    [Pg.284]    [Pg.285]    [Pg.93]    [Pg.195]    [Pg.314]    [Pg.479]    [Pg.265]    [Pg.121]    [Pg.201]    [Pg.545]    [Pg.545]    [Pg.166]    [Pg.400]    [Pg.321]    [Pg.244]    [Pg.446]    [Pg.529]    [Pg.598]    [Pg.622]    [Pg.180]    [Pg.139]    [Pg.59]    [Pg.68]    [Pg.81]    [Pg.337]    [Pg.33]    [Pg.35]    [Pg.37]    [Pg.184]    [Pg.251]    [Pg.12]   
See also in sourсe #XX -- [ Pg.31 ]




SEARCH



Mass spectrometry single-stage

Single nucleotide polymorphism mass spectrometry

Single particle mass spectrometry

Single-cell Fourier transform mass spectrometry

Single-collector inductively coupled plasma mass spectrometry

Single-ion mass spectrometry

Single-particle analysis, mass spectrometry

© 2024 chempedia.info