Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Shift, laboratory data

Object in this section is to review how rheological knowledge combined with laboratory data can be used to predict stresses developed in plastics undergoing strains at different rates and at different temperatures. The procedure of using laboratory experimental data for the prediction of mechanical behavior under a prescribed use condition involves two principles that are familiar to rheologists one is Boltzmann s superposition principle which enables one to utilize basic experimental data such as a stress relaxation modulus in predicting stresses under any strain history the other is the principle of reduced variables which by a temperature-log time shift allows the time scale of such a prediction to be extended substantially beyond the limits of the time scale of the original experiment. [Pg.41]

It was shown in laboratory studies that methanation activity increases with increasing nickel content of the catalyst but decreases with increasing catalyst particle size. Increasing the steam-to-gas ratio of the feed gas results in increased carbon monoxide shift conversion but does not affect the rate of methanation. Trace impurities in the process gas such as H2S and HCl poison the catalyst. The poisoning mechanism differs because the sulfur remains on the catalyst while the chloride does not. Hydrocarbons at low concentrations do not affect methanation activity significantly, and they reform into methane at higher levels, hydrocarbons inhibit methanation and can result in carbon deposition. A pore diffusion kinetic system was adopted which correlates the laboratory data and defines the rate of reaction. [Pg.56]

Monitor and assess laboratory data WBC count with differential (goal is a reduction in WBC count if elevated initially and resolution of left shift), renal and/or hepatic function (consider need for dosage adjustments), other labs as indicated (e.g., ESR, CRP). [Pg.1031]

A laboratory shift table is a tabular display that can show you how a population s laboratory data change, or shift, over time. Often you want to see what happens to the patients lab values after therapeutic intervention. Did certain lab parameters drop below or above normal range Are there laboratory tests that have become of clinical concern A shift table can provide this information at a glance. Although the example that follows is focused on laboratory data, a shift table can be used to show the movement of any categorical data over time. [Pg.169]

The following is a table specification for a laboratory normal range shift table. In order to create this table, you need to have a laboratory data set where the lab values have been flagged as normal, low, or high. The highlighted items in the table shell are parameters that change for the laboratory data in the study. [Pg.169]

One aspect of CAD detection to be aware of is that analyte response is directly proportional to percentage of organic however, the magnitude of this effect is very similar for all compounds.69 Therefore, a shift in retention time will cause a difference in response. Because of the uniformity of response characteristics outlined above, CAD is a very interesting option as a universal detection system for HPLC. From the author s experience, it is a very simple detector to utilize and can be integrated with laboratory data collection system quite easily with the analog output. [Pg.371]

Based on experience in one of the author s laboratories (GEM), cryogenic NMR probe technology may have the single biggest positive impact on increasing the facility with which long-range heteronuclear chemical shift correlation data may be acquired. [Pg.10]

Many questions concerning the interpretation of NMR shift reagent data remain unanswered. Hopefully, single-crystal structural determinations of shift reagent-substrate complexes will allow basic structural principles to be deduced. The structures of Eu(thd)3(DMF)2, Eu(thd)3-(DMSO), Eu(thd)3(l,10-phenanthroline), and Yb(thd)3(DMSO) were recently determined (23). These structures, in conjunction with structures determined in other laboratories see Ref. 2, pp. 368-369), lead to several generalizations concerning the stereochemistry of shift reagent complexes. [Pg.227]

An examination of some laboratory runs with diluted C150-1-02 catalyst can illustrate this problem. In one run with 304°C at inlet, 314 °C at exit, and 97,297 outlet dry gas space velocity, the following results were obtained after minor corrections for analytical errors. Of the CO present (out of an inlet 2.04 mole % ), 99.9885% disappeared in reaction while the C02 present (from an initial 1.96%) increased by over 30%. Equilibrium carbon oxides for both methanation reactions were essentially zero whereas the equilibrium CO based on the water-gas shift reaction at the exit composition was about one-third the actual CO exit of 0.03 mole %. From these data, activities for the various reactions may be estimated on the basis of various assumptions (see Table XIX for the effect of two different assumptions). [Pg.77]

It is concluded that a fully satisfactory system for calculating simultaneous reactions of CO and COo with H2 and H20 will require a schedule of the effect of CO on C02 methanation as a function of temperature. This effect will probably be different with different particle sizes. From a commercial standpoint, the particle size range may be too small to require much difference in the treatment of the data, but in the laboratory very small particle size may lower the CO methanation rate. A simple kinetics system such as that derived from Equation 3 may be satisfactory for all the reactions. It is unlikely that reliable data will be collected soon for the shift reaction (since it is of a somewhat secondary nature and difficult to study by itself), and therefore a more complicated treatment is not justified. [Pg.78]

Another major change was the shift from extensive use of field laboratory exploration techniques to the laboratory techniques hke ICP-AES and INAA. These produce a higher quality data than had resulted from the dc arc and other field techniques, with respect to both repeatability of measurement and improved detection limits. The metrology laboratory certifications for As and Hg in soils and sediments as key environmental toxins provided strong support to mineral exploration programs. [Pg.226]

Over the years, many instruments have been developed for and used in the scientific laboratory. Today, the computer is used as a major tool in the scientific laboratory for the capture, manipulation, transfer, and storage of data. Consequently, the concern for data quality has shifted from the instruments that are used in the generation of the data to these electronic systems, often neglecting the fact that the data are only as accurate as the instrument measurements. For instance, many electronic systems can be used in chromatography analysis, from the electronic log book where the test substance inventory is kept, throughout data capture in the instrument, to the digitized electronic signal that is the raw data on the computer network. For crop residue samples, the... [Pg.1039]

All chemical shift data presented in this book come either from the primary literature or from spectra obtained in the author s laboratory. All spectra actually depicted in the book derive from spectra obtained by the author at the University of Florida. All data from the literature were obtained via searches using MDL Crossfire Commander or SciFinder Scholar. Persons interested in accessing such primary literature can do so readily via these databases by simply searching for the specific compound mentioned in the text. [Pg.19]

N.m.r. spectroscopy T.l.c.-m.s. analysis of oligosaccharides coupled to a lipid amine (neoglycolipids) H n.m.r. spectrum in D20 after exchange of free protons with deuterium Experiments conducted at 295 K, with acetone as the internal standard (set at 2.225 p.p.m. from 4,4-dimethyl-4-silapentane-1-sulfonate) Results compared, to within 0.005 p.p.m. (laboratory-to-la-boratory variation) of data in the literature Conformational studies by n.O.e. experiments Natural-abundance-13C analysis Chemical-shift assignment by 2D H- H and H-13C n.m.r. spectroscopy... [Pg.312]


See other pages where Shift, laboratory data is mentioned: [Pg.74]    [Pg.719]    [Pg.128]    [Pg.641]    [Pg.5]    [Pg.465]    [Pg.290]    [Pg.121]    [Pg.304]    [Pg.389]    [Pg.70]    [Pg.345]    [Pg.191]    [Pg.210]    [Pg.215]    [Pg.143]    [Pg.73]    [Pg.52]    [Pg.290]    [Pg.157]    [Pg.52]    [Pg.210]    [Pg.324]    [Pg.330]    [Pg.5]    [Pg.741]    [Pg.6]    [Pg.171]    [Pg.183]    [Pg.54]    [Pg.538]    [Pg.471]    [Pg.94]    [Pg.78]   
See also in sourсe #XX -- [ Pg.169 , Pg.170 , Pg.171 , Pg.172 , Pg.173 , Pg.174 , Pg.175 ]




SEARCH



Laboratory data analyses shift analysis

Laboratory data shift tables

© 2024 chempedia.info